• Title/Summary/Keyword: dental alloy

Search Result 488, Processing Time 0.021 seconds

Effects of HA/TiN Coating on the Electrochemical Characteristics of Ti-Ta-Zr Alloys (Ti-Ta-Zr합금의 전기화학적 특성에 미치는 HA/TiN 코팅의 영향)

  • Oh, Mi-Young;Kim, Won-Gi;Choe, Han-Cheol
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.10
    • /
    • pp.691-699
    • /
    • 2008
  • Electrochemical characteristics of Ti-30Ta-xZr alloys coated with HA/TiN by using magnetron sputtering method were studied. The Ti-30Ta containing Zr(3, 7, 10 and 15wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and coating, and then coated with HA/TiN, respectively, by using DC and RF-magnetron sputtering method. The analyses of coated surface and coated layer were carried out by using optical microscope(OM), field emission scanning electron microscope(FE-SEM) and X-ray diffractometer(XRD). The electrochemical characteristics were examined using potentiodynamic (-1,500 mV~ + 2,000 mV) and A.C. impedance spectroscopy(100 kHz ~ 10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructure of homogenized Ti-30Ta-xZr alloys showed needle-like structure. In case of homogenized Ti-30Ta-xZr alloys, a-peak was increased with increasing Zr content. The thickness of TiN and HA coated layer showed 400 nm and 100 nm, respectively. The corrosion resistance of HA/TiN-coated Ti-30Ta-xZr alloys were higher than that of the non-coated Ti-30TaxZr alloys, whic hindicate better protective effect. The polarization resistance($R_p$) value of HA/TiN coated Ti-30Ta-xZr alloys showed $8.40{\times}10^5{\Omega}cm^2$ which was higher than that of non-coated Ti-30Ta-xZr alloys.

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

Mechanical Properties of Precious Metal-Ceramic Alloy Joined by the Laser-Welding and the Soldering Method (레이저 용접과 납착법으로 연결된 귀금속성 금속-도재 합금의 물리적 성질)

  • Oh, Jung-Ran;Lee, Seok-Hyung;Woo, Yi-Hyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.269-279
    • /
    • 2003
  • This study investigated the mechanical properties of precious metal-ceramic alloy joined by the laser-welding and the soldering compared with the parent metal. Twenty-four tensile specimens were cast in precious metal-ceramic alloy and divided into three groups of eight. All specimens in the control group(group 1) were left in the as-cast condition. Group 2 and 3 were the test specimens, which were sectioned at the center. Eight of sectioned specimens were joined by soldering with a propane-oxygen torch, and the remaining specimens were joined by laser-welding. After joining, each joint diameter was measured, and then tested to tensile failure on an Instron machine. Failure loads were recorded, and then fracture stress(ultimate tensile strength), 0.2% yield strength and % elongation calculated. These data for three groups were subjected to a one-way analysis of variance(ANOVA). Neuman-Keuls post hoc test was then used to determine any significant differences between groups. The fracture locations, fracture surfaces were examined by SEM(scanning electron microscope). The results were as follows: 1) The tensile strength and 0.2% yield strength of the soldered group($280.28{\pm}49.35MPa$, $160.24{\pm}26.67MPa$) were significantly less than both the as-cast group($410.99{\pm}13.07MPa$, $217.82{\pm}17.99MPa$) and the laser-welded group($383.56{\pm}59.08MPa$, $217.18{\pm}12.96MPa$). 2) The tensile strength and 0.2% yield strength of the laser-welded group were about each 98%, 99.7% of the as-cast group. There were no statistically significant differences in these two groups(p<0.05). 3) The percentage elongations of the soldered group($3.94{\pm}2.32%$) and the laser-welded group($5.06{\pm}1.08%$) were significantly less than the as-cast group($14.25{\pm}4.05%$) (p<0.05). 4) The fracture of the soldered specimens occurred in the solder material and many porosities were showed at the fracture site. 5) The fracture of the laser-welded specimens occurred also in the welding area, and lack of fusion and a large void was observed at the center of the fracture surface. However, the laser-welded specimens showed a ductile failure mode like the as- cast specimens. The results of this study indicated that the tensile strengths of the laser-welded joints were comparable to those of the as-cast joints and superior to those of the soldered joints.

A Study of Ni-resistant bacteria isolated from gingival crevicular fluid on the patients wearing Ni-Cr alloy prosthesis (In terms of molecular biological aspects) (니켈-크롬 합금 보철물 주위 치은열구 내에서 발견된 니켈 내성 균주에 관한 분자생물학적 연구)

  • Chae, Young-Ah;Woo, Yi-Hyung;Choi, Boo-Byung;Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.741-755
    • /
    • 1999
  • As a material of metal-ceramic prosthesis, nickel as a form of Ni-Cr alloy has been used for many dental prostheses in many cases. However, several problems in use of the alloy have been revealed (ex : tissue stimulation, skin allergy, hypersensitivity, cytotoxicity and carcinogenecity). Little is known about nickel with respect to the relationship between Ni-prosthesis and gaining of Ni-resistance in oral microorganisms. The present study was undertaken to check wheather use of Ni-prosthesis leads to occurrence of Ni-resistant microorganisms. So this study may suggest the possible relationships between the oral microorganisms and nickel-resistance in oral environment. Bacteria were isolated from the gingival crevicular fluid on the pateints wearing Ni-Cr prosthesis. The isolated bacteria were tested for their Ni-resistance in nickel containing media at different concentration from 3mM to 110mM. E. coli HB101 was used as control. The Ni-resistant bacteria were isolated and biochemically identified. The Ni-resistant bacteria were tested several bio-chemical, molecular-biological tests. Performed tests were ; measuring the growth curve, antibiotic test, growth ability test in liquid media, isolation of the chromosome and plasmid, digestion of DNA by restriction enzyme, electrophoresis of chromosome and plasmid DNA, identification of Ni-resistant genes by the DNA hybridization. The results were as follows: 1) The bacteria isolated from gingival crevicular fluid on the patients wearing Ni-Cr alloy pros-thesis showed nickel-resistance. 2) The isolated microorganisms grew at nickel containing media of high concentrations (60mM-110mM). 3) Based on the biochemical tests, the isolated microorganisms were identified as Enterococcus faecalis(13 cases), Klebsiella pneumoniae(1 case) and Enterobacter gergeviae(1 case). 4) Enterococcus faecalis expressed not only nickel resistance but also the multi-drug resistance to several antibiotics ; chloramphenicol, kanamicin, streptomycin, lincomycin, clindamycin. However, all strain showed the sensitivity against the tetracycline. 5) DNA hybridization result suggest that there is no homology between the previousely known gene of nickel resistance in Klebsiella pneumoniae and chromosomal DNA of Enterococcus faecalis.

  • PDF

Experimental studies on Gingival Response to Dental Restorations. (각종(各種) 금속치관(金屬齒冠)이 치간(齒齦)에 미치는 영향(影響)에 관(關)한 실질적(實驗的) 연구(硏究))

  • Lee, Young-Choo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.42-47
    • /
    • 1968
  • The purpose of this study was to determine the gingival response to the various restorations for 3 weeks, 5 weeks and 8 weeks respectively after they had been inserted in 36 tooth of 3 dogs. The histopathological observation was also performed to evaluate the effect of the various restorations on gingival tissue. They included gold, copper and nickel-chrome alloy. The following findings were obtained. 1. The gingivae adjacent to the well adapted and polished restorations and their margins with a level of gingival crest were grossly and histopathologically found no specific changes. 2. The gingive adjacent to the ill fitting and unpolished restorations and their margins with subgingival extension of 1 to 1.5mm were not grossly found any changes. 3. There were no obvious difference in gingival response among the various alloys in histopathological observation.

  • PDF

Surface Characteristics of Sintered Ni-Cr Alloy for Dental Casting (치과주조용 Ni-Cr합금 소결체의 표면특성)

  • Kim, Hyeon-Ju;Kim, Eun-Sil;Kim, Seong-Hwan;Jo, Chae-Ik;Park, Geun-Hyeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.193-193
    • /
    • 2013
  • 본 연구에서는 치과용 주조합금의 개발을 위하여 Ni-Cr 및 Ni-Cr-Ti합금을 소결체를 제조하고 그 표면특성을 조사하였다. 결정조직은 Ti가 참가되면 결정립이 미세화되는 경향을 나타내었으며 Ti가 첨가되면 결정구조가 다르게 나타났다. Ti함량이 증가할수록 경도 값은 증가하였으며 Ti가 10wt% 첨가되었을 때 가장 높은 값을 보였다. 또한 압분체 < 소결체 < 벌크상태로 증가하는 경향을 보였다. 부식실험 결과 내식성은 Ti 함량이 증가함에 따라 증가하는 경향을 보였으며 벌크상태의 시편이 가장 좋은 내식성을 보였다.

  • PDF

Zirconia Ceramic Powder Coating of Ti-6AI-4V by Laser Cladding (레이저 클래딩을 이용한 Ti-6AI-4V의 Zirconia 세라믹 분말 코팅)

  • Kang, Kyung-Ho;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.783-788
    • /
    • 2011
  • The recent development of bio-ceramic material is being studied in various bio-material engineering field. There are lots of technical difficulties because manufacturing or bonding technique are required bio-friendliness, cleanliness and persistence. Zirconia ceramic powder is cladded on Ti-6AI-4V metallurgically by laser cladding processing. Laser cladding system with powder feeding delivery is designed and manufactured for optimum processing condition. Increasing of manufacturing speed and good quality of clad layer are achieved by application of preheating of substrate before laser cladding. The thin dilution and good clad layer on the substrate are obtained for applications of bio-materials such as the dental materials and the articulated joints of human body.

SURFACE DEGRADATION OF GALLIUM-ALLOYS DURING TOOTH BRUSHING IN VITRO

  • Lee, Seok-Hyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.309-315
    • /
    • 2003
  • When the exposure surface of restoration is brushed with various toothpaste in the mouth, wear or undesirable surface deposit of restoration can occur. Surface change of gallium alloys according to brushing and toothpaste may directly affect oral hygiene. The aim of this study was to evaluate the surface alterations of Gallium alloys during tooth brushing with different prophylactic agents. Two gallium-alloys and an amalgam as a control were investigated. Without and with brushing were applied with three kinds of prophylactic agents on the sample for 0, 1, 5, 10, 60 and 360 minutes. At each time interval, surface roughness was recorded by a profilometer and some pictures were taken by a SEM. All results were analyzed by the one-way ANOVA, followed by Tukey multiple comparisons and the simple linear regression analysis. The results indicate that gallium alloys are more susceptible to surface degradation during tooth brushing than amalgam with respect to the specific prophylactic agent used.

Analyses of Influence of Frictional Heat on the Contact Stress of High-speed Micro-gears

  • Kim, Cheol;Kim, Hyeong-Seok
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.244-248
    • /
    • 2015
  • When a small gear rotates at a very high speed over 40,000 rpm, frictional heat is generated on the gear surfaces. Thermal deformations and stresses arising from frictional heat may lower the efficiency and fatigue life of the high-speed gear. Especially, such frictional heat has much stronger effects on the performance of millimeter-sized high-speed gears used for surgical and dental hand-pieces, due to a small surface area. An analytical equation was derived to calculate frictional temperature on a mating gear surface and conduction heat transfer analysis was performed. Thermal deformation and contact stresses were then calculated using FEM for gears used for medical hand-pieces. The contact stresses of the meshed gear and pinion increase by 19.4% and 16.4%, respectively, when the frictional thermal deformations are considered.

THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS (주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구)

  • Oh Su-Yeon;Vang Mong-Sook;Yang Hong-So;Park Sang-Won;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.