• Title/Summary/Keyword: dental acrylic resin

Search Result 182, Processing Time 0.026 seconds

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.6
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE (임플란트-지대주-나사의 적합에 관한 연구)

  • Kim Nak-Hyung;Chung Chae-Heon;Son Mee-Kyoung;Back Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.

PEKK(Polyetherketoneketone) Surface Treatment Effects on Shear Bond Strength to Dental Veneering Resin (PEKK(Polyetherketoneketone) 표면처리가 치과용 베니어 레진의 전단결합강도에 미치는 영향)

  • Moon, Yun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.93-99
    • /
    • 2019
  • The purpose of this study was to investigate the bond strength between PEKK(Polyetherketoneketone) and Sinfony(3M ESPE, Seefeld, Germany) the dental composite resin by proposing the three representative surface treatment methods and evaluate to see if they affect the bond strength between two materials. A total of 30 PEKK($Pekkton^{(R)}$ Ivory, $Cendres+M{\acute{e}}taux$, Bienne, Switzerland) specimens were prepared, embedded in acrylic resin, polished(P 1200 grid) to surface, and each group was divided into 10 specimens. After then, by the surface treatment method, it classified into three groups(n=10) such as Air abrasion group(PN), applying Single Bond Universal(3M ESPE) after Air abrasion(PB), applying OPAQUE(3M ESPE) after Air abrasion(PO). Then, veneering was performed by using Sinfony(3M ESPE, Seefeld, Germany). All completed specimens were allowed to rest in a $37^{\circ}C$ water bath for 24 hours. Shear bond strength of each group was measured and fracture patterns were classified. Statistic analysis was performed with One-way ANOVA followed by post hoc Scheffe tast (p<.05). Statistical analysis was performed using the SPSSWIN 21.0 program. As a result of one-way ANOVA, the average value of PB group was $27.67{\pm}4,18MPa$ and it was shown as the highest bond strength, PN and PO were $20.43{\pm}1.70$ and $19.8{\pm}4.77MPa$ each, and these were relatively low(F=18.4, P<.001), and as the post-test the Scheffe test was conducted and verified (p<.05). After examining the scheffe test, it was showed significant differences as PB>PO, PB>PN(p<.001). Through this study, in order to enhance the bonding force between PEKK and the composite resin, perform the Air abrasion and surface treatment by using Single Bond Universal(3M ESPE) is recommended, and as coMPared with other studies. And it is assumed that the increase of the application time of the Air abrasion affects the increase of the shear bond strength. Thus, further research is required.

MORPHOLOGICAL CHANGES OF DENTIN SURFACE TREATED WITH VARIOUS DENTIN SURFACE CONDITIONERS (수종(數種) 표면처리제(表面處理劑)에 의(依)한 상아질(象牙質) 표면(表面)의 형태(形態) 변화(變化)에 관(關)한 연구(硏究))

  • Cho, Jin-Ho;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.323-334
    • /
    • 1988
  • The purpose of this study was to observe the effect of dentin surface conditioners on the dentin surfaces. Freshly extracted human molars were used in this study. They were stored at $4^{\circ}C$ saline solution before experiment. The crown portions of the teeth were cut in various directions by means of wet diamond point to expose dentin which include transverse, vertical oblique, horizontal and oblique cut to the long axis (Fig. 1). Each tooth was then mounted with self curing acrylic resin in brass ring to expose the flattened dentin surfaces. Final finish was accomplished by grinding the dentin specimens with wet No. 180 and No. 600 grit silicon carbide abrasive paper until a 6.0mm in diameter on a dentin surface was exposed without pulp exposure. The specimens were divided into 9 groups according to the modes of dentin treatment procedure. The following surface treatments were applied on these preparation surfaces; Group 1: unetched (control group) after finish with No. 600 silicon carbide abrasive paper. Group 2: etched with 30% phosphoric acid for 60s Group 3: etched with 10-3 solution for 60s Group 4: Cleaned with 5% NaOCl for 30s Group 5: applied Dentin Adhesit Group 6: cleaned with 5% NaOCl followed by applying the Dentin Adhesit$^{(R)}$ Group 7: applied Photo Bond on the unetched dentin followed by applying the Photo Clearfil Bright Group 8: Etched with 30% phosphoric acid followed by applying Photo Bond and Photo Clearfil Bright Group 9: etched with 10-3 solution followed by applying Photo Bond and Photo Clearfil Bright All the specimens were stored in $37^{\circ}C$ under 50% relative humidity for 24 hours before observations. The specimens in 7, 8, and 9 group, omitting the group 1 to 6, were demineralized in 10% HCl for 10s in order to observe the resin tags. All the specimens in each group were then dried at room temperature. The dried specimens were ion coated with Eiko ion coater (Eiko-engineering Co.), and observed in Hitachi S-430 Scanning electron microscope (Hitachi, Co. Tokyo) at 15KV. The following results were obtained as follows; 1. The smear layers were still remained in group 1,2,4,5, and 6. 2. There is no effect of 5% NaOCl and 30% phosphoric acid on the changes of dentin morphology 3. The dentin treated with 10-3 solution, indicating the tubules opened when the smear layer and the dental plug dissolved. 4. In case of applying the bonding agents the resin tag was not formed at the deep area of dentinal tubules, but in case of applying the Dentin Adhesit$^{(R)}$ that was not.

  • PDF

Detorque Values of Various Compatible Dental Implant Screws (호환 가능한 수종의 치과용 임플란트 나사의 풀림토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • This study evaluated the effect of 3 different compatible screws on the detorque values in a multiple implant-supported superstructure and single implant abutments. An implant superstructure directly connected to 4 implants was screwed to 6 experimental dental stone casts made by acrylic resin splinted impressions, using 20 Ncm. The detorque values of screws were measured twice. Three compatible abutment screws used in this study were TorqTite screw, Gold-Tite screw, and, Titanium screw. And, using single implant abutments (GoldAdapt Engaging abutments), the detorque values of 3 different screws were measured twice on 2 implants of 5 experimental casts. According to statistical analysis of detorque values using mixed model at a .05 level of significance, no statistically significant differences among 3 different compatible screws were found in a multiple implant-supported superstructure (p>0.05). But, in single implant abutments, statistically significant differences among 3 different compatible screws were found (p=0.0175). The detorque values of TorqTite(p=0.0462) and Titanium(p=0.0348) screws were significantly higher than those of Gold-Tite screw, but no statisticantly significantlydifferences were found between TorqTite and Titanium screws(p>0.05). Therefore, various compatible screws showed significant effects on the detorque values for single implant abutment, but, showed no significant effects for a multiple implant-supported superstructure.

BOND STRENGTH OF BONDED AMALGAM USING DENIAL ADHESIVES (치과용 접착제를 사용한 접착 아말감의 결합 강도)

  • Kam, Dong-Hoon;Lee, Sang-Dae;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.284-295
    • /
    • 1999
  • The purpose of this study was to measure and analyze the bond strength of bonded amalgam using dental adhesives and to compare this with light-curing composite resin. Sections 8mm in diameter were punched out from the labial surface of bovine anterior teeth. These were embedded in clear acrylic resin blocks with labial surface facing out. 55 specimens were made for enamel and dentin each. After dividing these into 5 groups, group 1: Superbond C&B, group 2: Panavia 21, group 3: All-Bond 2, group 4: Fuji I Glass Ionomer Luting Cement, group 5: Scotchbond Multi-Purpose(Restorative Z-100), molds with holes of 6.3mm in diameter and 1.5mm in depth were placed over the specimens. The exposed tooth surfaces were treated with adhesives and the molds were filled with amalgam. In group 5, the mold was filled with composite resin and light-cured for 40 seconds. The author measured all specimens for bond strength 24 hours after amalgam filing and analyzed fracture surfaces. The following results were obtained: 1. Among the dentin groups, groups 1, 2 and 4 showed significantly lower bond strength compared with group 5(P<0.05). 2. Among the enamel groups, group 4 showed significantly lower bond strength compared with group 5(P<0.05). 3. In group 2, 2D showed significantly lower bond strength compared with group 2E(P<0.05). Other adhesives showed no such differences in bond strength between dentin and enamel(P>0.05). 4. Cohesive failure was observed in groups 1E and 5D, while mixed failure was seen in groups 1 and 5. Only adhesive failures were noted in groups 2, 3, 4.

  • PDF

Microinjection of Glutamate into the Amygdala Modulates Nociceptive and Cardiovascular Response in Freely Moving Rats

  • Ahn, Dong-Kuk;Kim, Yun-Sook;Park, Jae-Sik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.6
    • /
    • pp.687-693
    • /
    • 1998
  • This study was performed to examine the mean arterial pressure and nociceptive jaw opening reflex after microinjection of glutamate into the amygdala in freely moving rats, and to investigate the mechanisms of antinociceptive action of amygdala. Animals were anesthetized with pentobarbital sodium (40 mg/kg, ip). A stainless steel guide cannula (26 gauge) was implanted in the amygdala and lateral ventricle. Stimulating and recording electrodes were implanted into each of the incisor pulp and anterior digastric muscle. Electrodes were led subcutaneously to the miniature cranial connector sealed on the top of the skull with acrylic resin. After 48 hours of recovery from surgery, mean arterial pressure and digastric electromyogram (dEMG) were monitored in freely moving rats. Electrical shocks (200 ${\mu}sec$ duration, $0.5{\sim}2$ mA intensity) were delivered at 0.5 Hz to the dental pulp every 2 minutes. After injection of 0.35 M glutamate into the amygdala, mean arterial pressure was increased by $8{\pm}2$ mmHg and dEMG was suppressed to $71{\pm}5%$ of the control. Injection of 0.7 M glutamate elevated mean arterial pressure by $25{\pm}5$ mmHg and suppressed dEMG to $20{\pm}7%$ of the control. The suppression of dEMG were maintained for 30 minutes. Naloxone, an opioid receptor antagonist, inhibited the suppression of dEMG elicited by amygdaloid injection of glutamate from $28{\pm}4\;to\;68{\pm}5%$ of the control. Methysergide, a serotonin receptor antagonist, also inhibited the suppression of dEMG from $33{\pm}5\;to\;79{\pm}4%$ of the control. However, phentolamine, an ${\alpha}-adrenergic$ receptor antagonist, did not affect the suppression of dEMG. These results suggest that the amygdala can modulate both cardiovascular and nociceptive responses and that the antinociception of amygdala seems to be attributed to an augmentation of descending inhibitory influences on nociceptive pathways via serotonergic and opioid pathways.

  • PDF

Evaluation of Masseter Muscle Activity by Occlusal tooth Contact Patterns (교합접촉 형태에 따른 교근활성의 평가)

  • Kim, Hee-Jung;Kim, Jin-A;Min, Jeong-Bum;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.11-19
    • /
    • 2007
  • There are have been reports that the distribution of electromyographical(EMG) activity is determined in a predictable manner by both the location and number of occlusal contacts. However, these reports placed an emphasis on whole dentition. Inclined plane contacts in the frontal plane are classified as A-, B- or C-types. Objectives: The aim of this study was to evaluate the relation between occlusal tooth contact patterns and EMG activity of masseter muscle during maximum voluntary clenching. Methods: Fifteen healthy human subjects(Mean age; 25.3 years) volunteered to participate in this study. Acrylic resin overlays were fabricated for upper 2nd premolars and 1st molars bilaterally, and offered 3 types(A-, B- and AB- type contact). EMG activity of the masseter muscles was recorded bilaterally during maximum voluntary clenching. Statistical analysis was performed using the one-way ANOVA. Results: The group with a A-type contact showed a statistically lower EMG activity of masseter muscle than that of natural group(p<0.05) and that of B- and AB- type groups(p<0.01) on both upper 2nd premolars and upper 1st molars. Conclusions: These results suggest that occlusal tooth contact patterns have an influence on EMG activity of masseter muscle during maximum voluntary clenching.

Full mouth prosthodontic reconstruction on patient with occlusion collapse & decreased vertical dimension (교합 붕괴 환자의 수직고경거상을 동반한 완전 구강회복 증례)

  • Yoo, H.J.;Choi, M.H.;Kim, C.H.;Park, Y.R.;Kang, D.W.
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.115-124
    • /
    • 2003
  • One of the important things in the full mouth reconstruction is the determination of therapeutic position. Centric jaw relation is used as a therapeutic position for the full mouth reconstruction. There are several techniques associated with recording this position. Five clinically acceptable techniques are as follows: 1) Swallowing or free closure, 2) Chin point guidance, 3) Bimanual method 4) Myo-monitor technique, 5) Anterior deprogrammer. Centric relation obtained utilizing the anterior acrylic resin platform in this case. Another important thing in full mouth reconstruction is provisional restoration. Provisional restorations are an excellent diagnostic instrument, especially in full remain esthetics, phonetics, function, parafunction, and dysfunction after evaluation and acceptance through clinical trial with the provisional restorations should be accurately transferred to the final restorations to ensure the same clinical success. Especially, anterior guidance should be accurately transferred to the final restorations. An accurate anterior guidance is critical for optimal esthetics, phonetics, comfort, function, stress minimization, and longevity of teeth and restorations. To record optimum anterior guidance, customized anterior guide table is used in this case. Considering previously mentioned points, we did successive treatment. And it resulted in a better situation esthetically and functionally. Followings are what we cared in treating a patient in this case. 1) Accurate centric relation recording 2) Accurate transference of anterior guidance to the final restorations.

THE INFLUENCE OF IMPRESSION TRAYS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE-ARCH IMPRESSIONS (전악인상채득시 인상용 트레이가 경석고 모형의 정확도에 미치는 영향)

  • Ryu Su-In;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1992
  • The purpose of this study was to evaluate the accuracy of reproduction of stone casts made from complete-arch impressions using different trays. The trays used were : 1) nonperforated custom tray, 2) perforated custom tray, 3) nonperforated Rim-Lock tray, 4) perforated stock tray. Impressions were made from an dentulous acrylic resin model with metal inserts in first premolars and second molars. Transverse distance, sagittal distance and diagonal distance were measured using 4 landmarks. Measurements were made by using 3 dimensional measuring machine. The impression material used was an addition silicone. Impressions were poured at once with a Type IV dental stone. Data were analyzed using ANOVA and student t-test with a sample size of five. The results were as follows : 1. There were statistical differences in amount of dimensional change in according to the tray types. In amount of mean dimensional change, perforated custom tray was the first smallest, nonperforated custom tray was the second, nonperforated Rim-Lock tray and perforated stock tray were the largest. 2. There were statistical differences in amount of dimensional change between nonperforated custom tray and nonperforated Rim-Lock tray, and between perforated custom tray perforated stock tray. 3. There were satistical differences in amount of dimensional change between nonperforated custom tray and perforated custom tray, but there was not a statistical difference between nonperforated Rim-Lock tray and perforated stock tray. 4. There was not a statistical difference in amount of dimensional change between upper and lower arch in all tray types.

  • PDF