• 제목/요약/키워드: dental

검색결과 24,412건 처리시간 0.041초

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향 (The influence of Collar design on peri-implant marginal bone tissue)

  • 김지환;정문규;문홍석;한동후
    • 대한치과보철학회지
    • /
    • 제46권1호
    • /
    • pp.53-64
    • /
    • 2008
  • 임플랜트 주위 변연골의 흡수는 임플랜트의 기능적 및 심미적 성공에 큰 장애가 되는 요인이다. Adell은 임플랜트에 지대주 연결 후 첫 1년간 평균적으로 1.5mm의 변연골 소실을 보이고, 이 후에는 매년 0.1mm이하의 변연골 흡수가 있었다고 하였다(Adell et al.,1981). 이러한 변연골 흡수를 막기위한 많은 노력들이 행해져 왔다. 특히 임플랜트 collar의 특징에 따라서 변연골의 흡수가 달라질 수 있다. 본 연구의 목적은 임플랜트 collar에서의 laser microtexturing(microgroove)이 변연골 흡수에 미치는 영향에 대해 알아보고자 하는 것이다. 4종류의 임플랜트 총 101개를 식립한 환자 53명에서 임플랜트 식립시부터 보철물 장착한 후 평균 6개월 후 정기 검사 시까지의 임플랜트 주위 변연골의 흡수를 측정하여 비교하였다. 생물학적 폭경을 충분히 확보한 임플랜트(ITI standard)와 생물학적 폭경이 부족한 임플랜트 (ITI esthetic plus, Silhouette IC Laser-$Lok^{TM}$, Silhouette IC)에서 변연골 흡수의 차이를 비교하였고, 임플랜트 주위 변연골의 흡수에 대한 laser를 이용한 미세나사산의(Silhouette IC Laser-$Lok^{TM}$) 영향을 알아보았다. 다음의 결과를 얻었다. 1. ITI standard와 Silhouette IC Laser-$Lok^{TM}$ 이 ITI esthetic plus 와 Silhouette IC 보다 임플랜트 주위 변연골의 흡수가 적었고 (p<0.05), ITI standard 와 Silhouette IC Laser-$Lok^{TM}$ 사이에는 변연골의 흡수가 유의차가 없었고(P>0.05), ITI esthetic plus와 Silhouette IC 사이에도 변연골의 흡수가 유의차가 없었다(P>0.05). 2. 사용된 임플랜트 전체에 대한 상하악의 비교에서는 상하악 사이에서 임플랜트 주위 변연골의 흡수는 통계학적으로 유의한 차이가 없었다(p>0.05). 3. 흡수각도에 대한 비교에서도 4종류 임플랜트 그룹 간에 통계학적으로 유의한 차이는 없었다(P>0.05). 본 연구에서 제한이 있긴 하지만, 임플랜트 디자인에서 생물학적 폭경이 부족한 경우(ITI esthetic plus, Silhouette IC)에는 생물학적 폭 경 보상을 위한 임플랜트 주위 변연골의 흡수가 있었음을 보여주고 있으나, laser를 이용한 microgroove 가 부여된 임플랜트에서는 collar의 거칠기와 laser microtexturing 등의 특징에 의해 임플랜트 주위 변연골의 흡수가 적게 일어난 것이 관찰되었다. 심미적인 요구도가 높은 전치부에서 충분한 생물학적 폭경이 확보된 임플랜트를 식립할 경우 변연골의 흡수에 따른 치은퇴축에 의해 metal collar의 노출이 우려되기에 충분한 생물학적 폭경이 부여되지 않은 임플랜트를 선정하게 되는데 이때 collar에서의 laser microtexturing은 변연골의 유지에 도움이 되었다. 이것은 조직의 단단한 부착으로 인한 안정화로 추정해 볼 수 있는데, 이에 대해서는 더 장기간의 연구와 더 많은 수의 임플랜트를 대상으로 한 연구와 조직학적인 연구도 필요할 것으로 사료된다.

$Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구 (The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients)

  • 송영균;조인호;이종혁
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.470-478
    • /
    • 2008
  • 완전도재 수복물은 뛰어난 심미성을 가지고 있어, 환자들의 심미적 욕구를 충족시킬 수 있다. 이러한 도재관을 제작함에 있어 CAD/CAM 시스템을 이용하는 것은 시간과 비용을 절약할 수 있는 장점을 가지고 있으며, 정밀도 또한 점차 높아지고 있다. 특히 변연적합도는 수복물의 성공 여부에 중요한 요소이고, 이 분야에 대한 실험적 연구는 많이 보고되고 있으나 임상적인 연구는 아직 미흡한 실정이다. 본 연구에서는 CAD/CAM 시스템의 하나인 $Procera^{(R)}$ AllCeram 시스템의 변연적합도를 실제 환자의 수복물 상에서 측정함으로써 임상에 사용되는 CAD/CAM 시스템의 변연적합도를 연구하고자 하였다. 단국대학교 치과병원 보철과에 내원한 56명, 101개의 지대치에 대해 코핑 상태와 최종수복물의 변연오차를 입체광학현미경으로 측정하고 비교분석하여 다음과 같은 결과를 얻었다. 실험 결과, 코핑의 변연오차 ($53.84{\pm}38.83\;{\mu}m$)보다 최종 수복물에서의 변연오차 ($45.82{\pm}30.84\;{\mu}m$)가 더 낮은 값을 나타났으며, 이는 통계적으로 유의한 차이가 있었다 (P < .05). 각 측정 지점간 비교에서 역시 모든 변연에서 코핑 의 변연오차가 최종 수복물에서의 변연오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 구치부의 변연오차는 전치부의 변연오차보다 더 높은 값을 나타냈으나, 통계적으로 유의한 차이는 없었다. 설측 변연의 경우, 근심, 원심, 순측 변연의 오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 이상의 결과로 보아 $Procera^{(R)}$ 시스템의 Allceram 관의 변연적합도는 임상적 허용 범위 내에 있었으며, 특히 도재 축성후 변연적합도 는 더 우수해지는 것으로 나타났으며, 각 변연 중 설측 변연의 오차가 가장 큰 것은 주모형의 정보 입력시 순측 부위의 특성상 일어나는 오류로 사료된다. $Procera^{(R)}$ 시스템 Allceram 관 수복시 설측 변연에 더욱 주의를 기울이는 것이 좋은 변연적합을 얻는 데 도움이 될 것으로 사료되며, 앞으로 주모형 변연 부위의 변곡 정도에 따른 변연오차에 대한 연구가 필요할 것으로 사료된다.

레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향 (Effects of laser-irradiated dentin on shear bond strength of composite resin)

  • 김성숙;박종일;이재인;김계순;조혜원
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.520-527
    • /
    • 2008
  • 목적: 이 연구는 산부식 대신 레이저로 표면처리를 하였을 때 복합레진과의 전단결합강도에 어떤 영향을 주는지 알아보기 위해 시행되었다. 재료 및 방법: 치아 우식증이 전혀 없는 건전한 최근에 발치된 대구치를 레진으로 매몰하고 상아질을 노출시킨 뒤 표면연마를 시행하 였다. 치아는 10개씩 4그룹으로 나누었다. 1) 아무 처리도 하지 않은 군, 2) 35% 인산으로 산부식한 군, 3) Er:YAG laser 레이저 처리된 군, 4) Er,Cr:YSGG laser로 처리된 군. 시편에 상아질 접착제 Single Bond2 (3M/ESPE)를 도포하고, 직경 3 mm, 높이 3 mm의 투명한 플라스틱관을 치아면 위에 두고 복합레진을 축성하였다. 모든 시편은 24시간동안 $37^{\circ}C$증류수에 보관 후 만능시험기를 이용하여 전단결합강도를 측정하였다. 결과: 레이저 처리시 각각 Er:YAG 레이저 처리는 $3.98{\pm}0.88$ MPa, Er,Cr:YSGG 레이저 처리는 $3.70{\pm}1.55$ MPa의 결합강도를 보였고, 통계적으로 유의한 차이를 나타내지 않았다. 아무 처리도 하지 않은 군의 결합강도는 $1.52{\pm}0.42$ MPa로 가장 낮은 결합강도를 나타내었고, 산처리를 한 군이 $7.10{\pm}1.86$ MPa로 가장 높은 전단결합강도를 보였으며, 이들은 레이저 처리한 군과 비교시 통계적으로 P < .001 유의수준에서 유의한 차이가 있는 것으로 나타났다. 결론: 치아와 레진의 전단결합강도 비교시 레이저 처리는 아무 처리도 않은 군에 비해서는 높지만 인산 etching보다 그 결합력이 떨어진다.

CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구 (Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay)

  • 백철우;박철우;박준섭;류재준
    • 대한치과보철학회지
    • /
    • 제51권1호
    • /
    • pp.20-26
    • /
    • 2013
  • 연구 목적: 본 연구는 최근 심미수복에 주로 사용되는 CAD/CAM 세라믹 인레이와 각종 레진 시멘트간의 결합강도를 알아보고자 하였다. 연구 재료 및 방법: 원기둥 모양의 세라믹 블록(높이: 5 mm, 직경: 3 mm)을 Cerec3로 제작하고, 총 90개의 우식이 없는 대구치의 상아질 표면에 세 종류의 레진 시멘트(Unicem$^{(R)}$, Biscem$^{(R)}$, Variolink II$^{(R)}$)를 사용하여 각각 제조업체의 지시에 따라 접착했다. 90개의 시편을 레진 시멘트의 종류에 따라 3개의 군으로 나누고, 각 군의 절반은 $5-55^{\circ}C$, 5,000 cycle 조건 하에서 thermocycling을 시행하였고, 다른 절반은 시행하지 않았다. 모든 시편은 결합강도를 측정하기 전에 $37^{\circ}C$ 생리 식염수에 24시간 동안 보관되었다. 전단결합강도는 만능시험기를 이용하여 0.5 mm/min의 cross head speed로 측정하였다. 결과 값은 t-test 및 one-way ANOVA를 사용하여 통계 분석하였다. 결과: Unicem$^{(R)}$ 군의 전단결합강도가 thermocycling 후에 약간 감소했으나 3 개의 군 중 가장 높은 결합 강도를 보였다. Unicem$^{(R)}$ 및 Valiolink II$^{(R)}$ 군의 전단결합강도가 thermocycling에 영향을 받았지만 Biscem$^{(R)}$은 영향을 받지 않았다(P<.05). Thermocyling 전에는 3개의 군 간의 결합강도에 유의한 차이가 없었지만, thermocyling 후에는 Unicem$^{(R)}$과 Valiolink II$^{(R)}$ 군 간에 유의한 차이가 있었다(P<.05). 결론:CAD/CAM 세라믹 인레이 수복물을 치아에 접착할 때, etch-and-rinse 레진 시멘트인 Valiolink II$^{(R)}$ 대신self-adhesive 레진 시멘트인 Unicem$^{(R)}$과 Biscem$^{(R)}$을 사용해도 임상적으로 유용하다.

터널형 2급와동 충전재의 탄성계수와 전단결합강도 및 수복치의 변연융선 파절강도에 관한 연구 (ELASTIC CONSTANTS, SHEAR BOND STRENGTH OF TUNNEL RESTORATIVE MATERIALS AND MARGINAL RIDGE STRENGTH OF RESTORED TEETH)

  • 이가연;박영준;양규호
    • 대한소아치과학회지
    • /
    • 제23권3호
    • /
    • pp.746-763
    • /
    • 1996
  • An alternative design to conventional class II cavity preparation for proximal carious lesions is the tunnel preparation. It preserves the marginal ridge intact, thus making it possible to maintain the natural contact relationship with the adjacent tooth and minimize tooth reduction. This in vitro study was purposed to evaluate the effect of the materials' elastic constants and shear-bond strength on the marginal ridge fracture resistance of teeth restored by the tunnel technique, and to find the materials of choice for tunnel restorations. $Resinomer^{(R)}$, $Ketac-silver^{(R)}$, $Miracle-Mix^{(R)}$, and Tytin were used as restorative material. The elastic constants of each restorative material were evaluated by ultrasonic pulse measurement. Young's modulus and bulk modulus of the restorative materials were evaluated in three specimens for each material type. The shear-bond strength of the restorative materials to the dentin surface was measured after thermocycling 400 times between 6 and $60^{\circ}C$, using ten specimens for each material type. For measuring marginal ridge strength, 60 sound extracted molar teeth were distributed into six groups by size. Sound molar teeth were used as a Control group and unfilled prepared teeth were grouped as Unrestored. Another four groups were named Resinomer group, Ketac-Silver group, Miracle Mix group, and Tytin group by type of restorative material. Tunnel cavity preparation was done with ' 1/2, 2, and 4 round burs in sequence. Initial access to proximal surface was made through an occlusal access preparation started at least 2mm from the marginal ridge, and the proximal opening was formed about 2.5mm below the marginal ridge. After restoration and thermocycling, marginal ridge strength was measured using a universal testing machine. The results were as follows: 1. The Young's modulus of $Tytin^{(R)}$ was 63.95 GPa, followed by $Ketac-Silver^{(R)}$ 27.60 GPa, $Miracle-mix^{(R)}$ 18.48 GPa, and $Resinomer^{(R)}$ 10.74 GPa showing significant differences between the groups(P<0.05). The bulk modulus of the materials showed the same order as Young's modulus. The value of $Tytin^{(R)}$ showed 59.57 GPa indicating that it will deform less than other materials under the same stress. It was followed by $Ketac-Silver^{(R)}$ 23.57 GPa, Miracle $Mix^{(R)}$ 12.50 GPa, and $Resinomer^{(R)}$ 11.60 GPa. 2. The Resinomer group had a shear-bond strength of 7.41 MPa which was significantly higher than those of the Ketac-Silver group (1.80 MPa) and the Miracle Mix group (2.84 MPa) (P<0.01). All the specimens of Tytin group detatched from the dentin surface during thermocycling. 3. The mean marginal ridge strength of the Unrestored group(46.14 kgf) was significantly lower than that of the Control group (84.24 kgf) (P<0.01). The marginal ridge strength of teeth restored by the tunnel technique was, in order, Ketac-Silver group 74.06 kgf, Miracle Mix group 73.36 kgf, Resinomer group 63.47 kgf, and Tytin group 58.76 kgf. The Ketac-Silver, Miracle Mix, and Resinomer groups showed no significant difference with the Control group (P>0.05), but the Tytin group showed significantly lower strength compared to the Control group(P<0.05). The results showed that the marginal ridge strength of the teeth restored by the tunnel technique was not significantly lower than that of sound teeth. They also demonstrated that the bonding strength of the restorative material to the tooth surface should be high and the modulus of elasticity should not be lower than that of the tooth in order to restore the marginal ridge strength to its natural condition.

  • PDF

Pendulum 장치의 상악대구치의 원심이동에 대한 효과 (THE EFFECT OF DISTAL MOVEMENT OF UPPER MOLAR USING THE PENDULUM APPLIANCE)

  • 이창섭;김재광;강덕일;송광철;정현구;이상호
    • 대한소아치과학회지
    • /
    • 제28권3호
    • /
    • pp.488-495
    • /
    • 2001
  • II급 치성교합을 가진 환자에서는 I급 구치부 교합관계를 형성하기 위하여 상악 대구치의 원심이동이 필요하다. 본 연구에서는 pendulum장치를 이용한 상악 대구치의 원심이동시 대구치의 이동양상과 고정원의 전방이동 및 정출정도 등 치아와 골격에 미치는 영향을 평가하기 위하여 시행되었다. 상악 제1대구치를 원심이동시켜 I급 구치관계가 형성된 19명의 환자(남: 8명, 여: 11명, 평균연령 $11.68{\pm}1.52$세)에서 장치 장착 전과 장치제거 직후에 얻어진 측면두부방사선사진을 비교 분석하여 다음과 같은 결과를 얻었다. 1. I급 교합관계를 형성하기 위해서 제1대구치는 평균 $2.94{\pm}1.54mm$ 원심이동하였으며, $1.17{\pm}0.97mm$ 함입되었고, 소요기간은 평균 $18.13{\pm}7.95$일이었다. 2. 고정원으로 사용된 치아는 $1.34{\pm}1.40mm$로 유의하게 전방 이동하였으며, $0.48{\pm}0.99mm$ 정출되었다. 또한 절치는 유의한 전방이동 및 순측경사가 발생하였다(P<0.05). 3. 구개평면과 하악평면이 이루는 각은 유의한 증가를 보였다(P<0.05) 4. 제 1소구치 또는 제 1유구치가 고정원으로 이용된 경우 제2소구치 또는 제2유구치가 이용된 경우 보다 전방이동이 증가하였다(P<0.005) 5. 제2대구치의 발육단계에 따른 제1대구치 및 제2대구치의 이동양상은 어떤 항목과도 유의성이 없었다(P<0.05). 6. 얻어진 총 공간 중 74%는 제1대구치의 원심이동이, 26%는 소구치의 전방이동에 의하여 얻어졌다. 이상의 결과를 종합하여 볼 때 pendulum appliance는 상악 대구치의 원심이동에 매우 효과적이었으며, 고정원의 소실을 최소화하기 위해 제2유구치 또는 제 2소구치가 포함되어야 한다. 또한 제1대구치의 원심경사는 필연적으로 일어나며, 이를 최소화하기 위한 노력이 계속되어야 할 것으로 사료된다.

  • PDF

하악 영구치아의 발육과 연령과의 관계 및 치아 발육에 따른 치아의 위치 변화 (RELATIONSHIP BETWEEN THE DEVELOPMENTAL STAGE AND CHRONOLOGICAL AGE, AND THE CHANGES OF TOOTH POSITION IN RELATION TO THE TOOTH DEVELOPMENT ON MANDIBULAR PERMANENT TEETH)

  • 김현미;양승덕;김현정;김영진;남순현
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.607-617
    • /
    • 2002
  • 연령과 치아 발육상태 단계와의 상관관계, 치아의 발육에 따른 치아의 이동상태를 평가하기 위하여 최근 5년 이내에 경북대학교 병원에 내원한 아동(남아 446명, 여아 326명)의 파노라마 방사선사진을 대상으로 하여, Moorrees의 기준에 의하여 하악 영구치아의 발육단계를 평가한 후, 발육단계와 연령, 치조골내 치아의 위치를 평가하여 다음과 같은 결론을 얻었다. 치아의 발육시기는 치관이 완료될 때까지 남, 여의 차이가 없었으나, 치근형성이 되면서 부터는 남아보다 여아에서 더 빨리 발육되는 경향을 나타내었다. 치관형성의 완료시점의 평균연령은 남아 여아 각각에서 중절치 3.71, 4.05세, 측절치 4.44, 4.60세, 견치 5.35, 5.11세, 제1소구치 6.62, 6.36세, 제2소구치 7.36, 7.17세, 제1대구치 3.51, 3.69세, 제2대구치 7.90, 7.64세 이었고, 치근단이 폐쇄되기 전단계인 $A_{1/2}$는 중절치 8.70, 8.18세, 측절치 9.55, 8.99세, 견치 12.48, 11.60세, 제1소구치 12.30, 12.01세, 제2소구치 12.19, 12.26세, 제1대구치 912, 8.87세, 제2대구치 12.59, 12.45세 이었다. 치조골내의 교두점 위치는 치관형성 완료시까지는 거의 변화가 없었으나, 치근이 형성됨에 따라 빠르게 교합평면을 향해 이동하였고, 치근형성 완료단계(Rc)에서 다시 움직임 없이 정체되었다. 치근단의 위치는 치관형성 시작부터 치근 1/4 형성 시까지 일정한 위치에 유지되었으나, 그 후에 급격하게 교합면 쪽으로 이동하였고, 치근 3/4 형성시점부터 비교적 일정한 위치에 유지되었다. 치아의 석회화가 시작되는 초기의 치배 위치는 견치가 가장 하방에 위치하였으며, 그 다음이 제2소구치, 제1소구치, 측절치 제2대구치, 제1대구치 순이었고, 중절치가 가장 상방에 위치하였다.

  • PDF

유산구균 1370의 수용성 글루캔 형성에 영향을 미치는 인자 (FACTORS AFFECTING THE FORMATION OF SOLUBLE GLUCAN BY LACTOCOCCUS LACTIS 1370)

  • 오인근;양규호;정진;오종석
    • 대한소아치과학회지
    • /
    • 제27권2호
    • /
    • pp.185-191
    • /
    • 2000
  • Streptococcus mutans가 치태를 형성할 때, 유산구균 1370 (Streptococcus lactis 1370)이 생산하는 수용성 글루캔이 영향을 미친다. 본 연구에서는 여러 인자에 의한 수용성 글루캔 형성 정도를 유산구균 1370배양 상청액의 흡광도로 측정하여 다음과 같은 결과를 얻었다. 1. 5% 자당이 첨가된 M17 broth에서 유산구균 1370 배양 상청액의 흡광도는 높고 Streptococcus mutans 배양 상청액의 흡광도는 낮았으나, 통계학적인 유의성은 없었다. 2. M17 broth에 10% 자당을 첨가하여 유산구균 1370을 배양할시 배양 상청액의 흡광도는 첨가하지 않을 때보다 높았다. (p<0.05), 배지 pH가 5에서보다 7에서 배양 상청액의 흡광도가 더 높았다(p<0.05). 3. $32^{\circ}C,\;37^{\circ}C,\;42^{\circ}C$$37^{\circ}C$에서 배양시 배양 상청액의 흡광도가 가장 높았으나 통계학적인 유의성이 없었고, 호기성 배양시보다 혐기성 배양시 배양 상청액의 흡광도가 더 높았다(p<0.05). 4. 배지의 $CaCl_2$ 농도가 1.0mM에서 (p<0.05), KCl 농도가 2.5mM에서 (p<0.05) 배양 상청 액의 흡광도가 높았다. 5. M17 broth에 5% 자당을 첨가한 배지에 유산구균 1370을 접종하여 배양한 배양 상청액과 배지를 1:3으로 가한 비커와이어 검사에서 Streptococcus mutans에 의하여 형성된 인공치태 무게는 5.6mg으로 5% 자당을 첨가하지 않을 때의 103.0mg에 비교하여 현저히 감소하였다 (p<0.05). 이상의 결과를 요약하면 유산구균 1370에 의한 수용성 글루캔의 형성은 자당이 함유된 배지나 세균 증식이 잘 되는 조건에서 증가하였으며, 수용성 글루캔이 Streptococcus mutans에 의한 인공치태 형성을 억제하였다.

  • PDF

탈회냉동건조골에 대한 성견의 치수조직반응에 관한 연구 (A HISTOPATHOLOGIC STUDY ON THE PULPAL RESPONSE TO DEMINERALIZED FREEZE-DRIED BONE IN DOGS)

  • 정문용;이창섭;박주철;이상호
    • 대한소아치과학회지
    • /
    • 제27권2호
    • /
    • pp.318-332
    • /
    • 2000
  • 탈회냉동건조골과 교원질을 치수치료제로서 이용할 수 있는지의 여부를 규명하기 위하여, 성견의 치아를 대상으로 치수절단술을 시행하여 치수조직의 염증반응, 재생성 상아질의 형성 등 치수조직반응을 평가하기 위하여 시행되었다. 체중 10kg 내외의 4마리의 성견 치아에 소독된 round bur을 이용하여 5급 와동을 형성한 후 치수절단술을 시행하였다. 대조군으로는 수산화칼슘으로 치수 복조을 시행하고 IRM으로 밀봉하였으며, 실험군으로는 교원질과 탈회냉동건조골을 이용하여 복조한 후 대조군에서와 같은 방법으로 밀봉하였다. 실험동물은 3일, 1주일, 2주일, 4주일 경과 후 관류 고정으로 희생되었으며, 조직표본을 제작한 후 광학현미경과 투과전자현미경으로 치수 조직 반응을 관찰 평가한 결과 다음과 같은 결론을 얻었다. 1. 모든 군에서 치수괴사 소견은 보이지 않았으며, 대조군과 실험 2군에서는 1주일 후부터 염증이 소실되었으나, 실험 1군에서는 2주까지 염증소견을 보이며 절단된 치수 측벽의 조상아세포들도 배열이 불규칙하였다. 2. 대조군에서는 2주부터 불완전한 상아질교가, 4주 경과 후에는 골양상아질과 완전한 상아질교가 관찰되었으며, 1군에서는 섬유성피막은 형성되었으나 조상아세포와 상아질교의 형성소견은 관찰되지 않았다. 2군의 경우 2주 경과 후 탈회냉동건조골 주위에 분화된 조상아세포들에 의해 형성된 상아전질과 재생성 상아질이 관찰되었으나 상아질교의 형성소견은 관찰되지 않았다. 3. 대조군과 2주군에서 1주일 경과 후에 크고 호염기성 핵을 갖는 세포들이 치수절단부 하방과 탈회냉동건조골 주위에 모여드는 양상을 보였는데, 이와 같은 현상은 대조군에 비해 2군에서 더욱 현저하였으며 시간이 경과될수록 규칙적으로 배열한 조상아세포와 재생성 상아질을 관찰할 수 있었다. 4. 대조군과 2군에서 조상아세포는 극성을 띤 핵, 조면내형질세망, 골지체, 분비과립 등을 포함하는 세포질과 유기기질을 분비하는 소견 등, 석회화가 이루어지는 초미세구조를 보였다. 이상의 결과를 종합하면 탈회냉동건조골은 치수의 미분화 간엽세포로부터 조상아세포의 분화를 유도하여 치수절단부위에 재생 상아질을 형성할 수 있는 것으로 사료된다.

  • PDF