• 제목/요약/키워드: delamination.

검색결과 999건 처리시간 0.027초

Effect of fiber-matrix adhesion on the fracture behavior of a carbon fiber reinforced thermoplastic-modified epoxy matrix

  • Carrillo-Escalante, H.J.;Alvarez-Castillo, A.;Valadez-Gonzalez, A.;Herrera-Franco, P. J.
    • Carbon letters
    • /
    • 제19권
    • /
    • pp.47-56
    • /
    • 2016
  • In this study, the fracture behavior of a thermoplastic-modified epoxy resin reinforced with continuous carbon fibers for two levels of fiber-matrix adhesion was performed. A carbon fiber with commercial sizing was used and also treated with a known silane, (3-glycidoxy propyl trimethoxysilane) coupling agent. Toughness was determined using the double cantilever test, together with surface analysis after failure using scanning electron microscope. The presence of polysulfone particles improved the fracture behavior of the composite, but fiber-matrix adhesion seemed to play a very important role in the performance of the composite material. There appeared to be a synergy between the matrix modifier and the fiber-matrix adhesion coupling agent.

압전필름센서를 이용한 복합재 평판의 저속충격 손상개시 모니터링 (Monitoring of Low-velocity Impact Damage Initiation of Gr/Ep Panel Using Piezoelectric Thin Film sensor)

  • 이관호;박찬익;김인걸;이영신
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 추계학술발표대회 논문집
    • /
    • pp.174-178
    • /
    • 2001
  • The piezoelectric thin film sensor can be used to interpret variations in structural and material properties, e.g. for structural integrity monitoring and assessment. To illustrate one of this potential benefit, PVDF film sensors are used for monitoring impact damage initiation in Gr/Ep composite panel. Both PVDF film sensors and strain gages are surface mounted to the Gr/Ep specimens. A series of impact test at various impact energy by changing impact mass and height is performed on the instrumented drop weight impact tester. The sensor responses are carefully examined to predict the onset of impact damage such as matrix cracking, delamination, and fiber breakage, etc. Test results show that the particular waveforms of sensor signals implying the damage initiation and development are detected above the damage initiation impact energy. As expected, the PVDF film sensor is found to be more sensitive to impact damage initiation event than the strain gage.

  • PDF

복합재 충격손상신호의 FBG센서 입사각도에 따른 주파수분포 특성에 관한 연구 (A Study on Frequency Characteristics of Impact Induced Damage Signals of Composite Laminates as the Incident Angle of an FBG sensor)

  • 방형준;송지용;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.235-239
    • /
    • 2005
  • In this research, we investigated the frequency characteristic of low-velocity impact induced damage signals on graphite/epoxy composite laminates using high-speed fiber Bragg grating(FBG) sensor system. Appling the FBG sensors to damage assessment, we need to study the response of FBG sensors as the damage signals of the different incident angles because FBG shows different directional sensitivity. In order to discriminate an impact induced damage signal from that of undamaged case, drop impacts with different energies were applied to the composite panel with different incident angle to the FBG sensor. Finally, detected impact signals were compared using frequency distributions of wavelet detail components in order to find distinctive signal characteristics of composites delamination.

  • PDF

섬유함유율에 따른 GF/PP 복합재료의 인장파괴거동 (Tensile Fracture Behavior of Glass Fiber/Polypropylene Composites for Various Fiber Volume Fraction)

  • 고성위;엄윤성
    • 수산해양기술연구
    • /
    • 제40권2호
    • /
    • pp.161-165
    • /
    • 2004
  • The main goal of this work is to study the effect of glass fiber volume fraction on the result of tensile test with respect to glass fiber/polypropylene(GF/PP) composites. The tensile test and failure mechanisms of GF/PP composites were investigated in the fiber volume fraction range from 10% to 30%. The tensile strength and the fracture strength increased with the increasing of the fiber volume fraction in the tested range. Fiber pull-out and debonding of this composites increased with the fiber volume fraction in thc tested range. The major failure mechanisms were classified into the debonding, the fiber pull out, the delamination and the matrix deformation.

상대재의 거칠기에 따른 GF/PUR 복합재료의 연삭마모거동 (Behavior of abrasive wear on counterpart roughness of glass fiber reinforcement polyurethane resin composites)

  • 김형진;고성위;김재동
    • 수산해양기술연구
    • /
    • 제47권3호
    • /
    • pp.267-272
    • /
    • 2011
  • The behavior of abrasive wear on counterpart roughness of glass fiber reinforcement polyurethane resin (GF/PUR) composites were investigated at ambient temperature by pin-on-disc friction test. The friction coefficient, cumulative wear volume and surface roughness of these materials against SiC abrasive paper were determined experimentally. The major failure mechanisms were lapping layers, ploughing, delamination, deformation of resin and cracking by scanning electric microscopy (SEM) photograph of the tested surface. As increasing the counterpart roughness the GF/PUR composites indicated higher friction coefficient. The surface roughness of the GF/PUR composites was increased as the sliding velocity was higher and the counterpart roughness was rougher in wear test.

Effect of Fluoride Conversion Coating on the Corrosion Resistance and Adhesion of E-painted AZ31 Magnesium Alloy

  • Fazal, Basit Raza;Moon, Sungmo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.124.2-124.2
    • /
    • 2016
  • Corrosion resistance and adhesion of electro-paint (E-paint) with fluoride conversion coating (FCC) on AZ31 Mg alloy were studied. Corrosion resistance and adhesion were studied as a function of FCC-treatment time and concentration of FCC-bath. Aqueous hydrogen fluoride (HF) solutions, with concentrations ranging from 0.5 M to 5 M, were used to form FCC on chemically polished AZ31 Mg alloy samples for six different times; 10, 30, 60, 90, 120, and 180s. The results from salt spray test (SST) showed that corrosion resistance of E-paint appeared to decrease with increasing FCC treatment times in low concentration FCC baths. The number of blisters formed on the FCC-treated samples increased with increasing FCC treatment time of more than 1 min in low concentration (0.5 M to 1 M) solutions. On the other hand, samples treated in the 5 M HF solution for 120s showed no delamination or blistering even after 1200h of SST.

  • PDF

외팔보의 결합조건에 따른 모드형상의 실험적 분석 (Experimental Analysis on Conditions of Joint for Cantilever Beam)

  • 윤지현;심현진;누룰파와지;이유엽;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1302-1306
    • /
    • 2007
  • Joints are used extensively in various industries. For instance, structural adhesives are used in place of the traditional mechanical fasteners, such as screws and bolts, because they are much lighter and spread the stresses more uniformly across the joints. For efficient designs of joints, knowledge of static and dynamic characteristics of joints is essential. Most analysis of joints are carried out using analytical equations or finite element method. In this paper, the characteristics of four conditions of lap-joint beam are investigated experimentally. The mode shapes and nodal points of beam show that there are different deformations in each condition. These deformations may cause high stresses and may initiate local cracking and delamination failures.

  • PDF

TiAIN 코팅한 핵연료봉 피복재의 프레팅 마멸 평가 (Fretting Wear Evaluation of TiAIN Coated Nuclear Fuel Rod Cladding Materials)

  • 김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.88-95
    • /
    • 2002
  • Fretting of fuel rod cladding material, Zircaloy-4 Tube, in PWR nuclear power plants must be reduced and avoided. Nowadays the introduction of surface treatments or coatings is expected to bean ideal solution to fretting damage since fretting is closely related to wear, corrosion and fatigue. Therefore, in this study the fretting wear experiment was peformed using TiAIN coated Zircaloy-4 tube as the fuel rod cladding and uncoated Zircaioy-4 tube as one of grids, especially concentrating on the sliding component. Fretting wear resistance of TiAIN coated Zircaloy-4 tubes was improved compared with that of TiN coated tubes and uncoated tubes and the fretting wear mechanisms were delamination and plastic flow following by brittle fracture at lower slip amplitude but severe oxidation and spallation of oxidative layer at higher slip amplitude.

  • PDF

Effect of a Multi-Step Gap-Filling Process to Improve Adhesion between Low-K Films and Metal Patterns

  • Lee, Woojin;Kim, Tae Hyung;Choa, Yong-Ho
    • 한국재료학회지
    • /
    • 제26권8호
    • /
    • pp.427-429
    • /
    • 2016
  • A multi-step deposition process for the gap-filling of submicrometer trenches using dimethyldimethoxysilane (DMDMOS), $(CH_3)_2Si(OCH_3)_2$, and $C_xH_yO_z$ by plasma enhanced chemical vapor deposition (PECVD) is presented. The multi-step process consisted of pre-treatment, deposition, and post-treatment in each deposition step. We obtained low-k films with superior gap-filling properties on the trench patterns without voids or delamination. The newly developed technique for the gap-filling of submicrometer features will have a great impact on inter metal dielectric (IMD) and shallow trench isolation (STI) processes for the next generation of microelectronic devices. Moreover, this bottom up gap-fill mode is expected to be universally for other chemical vapor deposition systems.

파티클보드와 아피통단판을 구성 접착한 복합판넬의 휨성질 (Bending Properties of the Composite Panel Composed of Particleboard and Apitong (Dipterocarpus grandiflorus) Veneer)

  • 이필우;윤형운;오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제19권3호
    • /
    • pp.53-61
    • /
    • 1991
  • Mechanical properties of composite panel made with 3mm thick Apitong(Dipterocarpus grandiflorus) veneer on each face of particleboard core of 4 different specific gravity were determined. The results obtained were as follows: 1. Measured MOR and MOE increased with an increased in specific gravity of particleboard core. 2. Test results showed that the difference in bending properties between flatwise bending and edgewise bending was present. The average MOE value of flatwise loading was higer than that of epdgewise loading. But it was shown reverse tendency in MoR and MOE. 3. The delamination between face veneer and core particle was found in flatwise bending but nell in edgewise. 4. These composite panel could be substituted for plywood and other panel materials in furniture making as considered suitable allowable stress and bending strength.

  • PDF