• 제목/요약/키워드: degree of conversion

검색결과 351건 처리시간 0.025초

A Numerical Study on the Effect of Inlet Guide Vane Angle on the Performance of Francis Hydraulic Turbine

  • Kim Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권7호
    • /
    • pp.750-757
    • /
    • 2005
  • The objective of this study is an understanding of the effect of inlet flow angle on the output power performance of a Francis hydraulic turbine, An optimum induced angle at the inlet of the turbine is one of the most important design parameters to have the best performance of the turbine at a given operating condition, In general. rotating speed of the turbine is varied with the change of water mass flowrate in a volute, The induced angle of the inlet water should be properly adjusted to the operating condition to have maximum energy conversion efficiency of the turbine, In this study. a numerical simulation was conducted to have detail understanding of the flow phenomenon in the flow path and output power of the model Francis turbine. The indicated power produced by the model turbine at a given operating condition was found numerically and compared to the brake power of the turbine measured by experiment at KIER. From comparison of two results, turbine efficiency or energy conversion efficiency of the model turbine was estimated. From the study, it was found that the rotating power of the turbine linearly increased with the rotating speed. It means that the higher volume flow rate supplied. the bigger torque on the turbine shaft generated. The maximum brake efficiency of the turbine is around 46$\%$ at 35 degree of induced angle. The difference between numerical and experimental output of the model turbine is defined as mechanical efficiency. The maximum mechanical efficiency of the turbine is around 93$\%$ at 25$\∼$30 degree of induced angle.

The effects of dentin bonding agent formulas on their polymerization quality, and together with tooth tissues on their microleakage and shear bond strength: an explorative 3-step experiment

  • Erfan, Mohmmad;Jafarzadeh-Kashi, Tahereh Sadat;Ghadiri, Malihe;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.333-345
    • /
    • 2014
  • PURPOSE. Bonding agents (BA) are the crucial weak link of composite restorations. Since the commercial materials' compositions are not disclosed, studies to formulize the optimum ratios of different components are of value. The aim of this study was to find a proper formula of BAs. MATERIALS AND METHODS. This explorative experimental in vitro study was composed of 4 different sets of extensive experiments. A commercial BA and 7 experimental formulas were compared in terms of degree of conversion (5 experimental formulas), shear bond strength, mode of failure, and microleakage (3 experimental formulas). Statistical analyses were performed (${\alpha}$=.05). The DC of selected formula was tested one year later. RESULTS. The two-way ANOVA indicated a significant difference between the shear bond strength (SBS) of two tissues (dentin vs. enamel, P=.0001) in a way that dentinal bonds were weaker. However, there was no difference between the four materials (P=.283). The adhesive mode of failure was predominant in all groups. No differences between the microleakage of the four materials at occlusal (P=.788) or gingival (P=.508) sites were detected (Kruskal-Wallis). The Mann-Whitney U test showed a significant difference between the microleakage of all materials (3 experimental formulas and a commercial material) together at the occlusal site versus the gingival site (P=.041). CONCLUSION. A formula with 62% bisphenol A-glycidyl methacrylate (Bis-GMA), 37% hydroxy ethyl methacrylate (HEMA), 0.3% camphorquinone (CQ), and 0.7% dimethyl-para-toluidine (DMPT) seems a proper formula for mass production. The microleakage and SBS might be respectively higher and lower on dentin compared to enamel.

Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements

  • Lima, Adriano Fonseca;Formaggio, Stephanie Ellen Ferreira;Zambelli, Ligia Franca Aires;Palialol, Alan Rodrigo Muniz;Marchi, Giselle Maria;Saraceni, Cintia Helena Coury;de Oliveira, Marcelo Tavares
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.271-277
    • /
    • 2016
  • Objectives: In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements. Materials and Methods: Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and $20J/cm^2$) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length ${\times}$ 2 mm in width ${\times}$ 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed. Results: No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions: On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.

아세트산비닐의 삼차부틸알코올계 저온 중합 및 비누화에 의한 고분자량 폴리비닐알코올의 합성 (Synthesis of High Molecular Weight Poly(vinyl alcohol) by Low Temperature Polymerization of Vinyl Acetate in Tertiary Butyl Alcohol and the Following Saponification)

  • 류원석;한성수;최진현;유상우;홍성일
    • 폴리머
    • /
    • 제24권5호
    • /
    • pp.610-620
    • /
    • 2000
  • 아세트산비닐(VAc)을 아조비스디메틸발레로니트릴(ADMVN) 및 삼차부틸알코올 (TBA)을 각각 개시제 및 용매로 하여 30, 40 및 5$0^{\circ}C$에서 용액중합하였다. 합성된 폴리아세트산비닐 (PVAc)을 비누화함으로써 고분자량 혼성배열 폴리비닐알코올(PVA)을 제조하였다. 중합조건들이 전환률, 가지화도 및 PVAc와 PVA의 분자량에 미치는 영향을 고찰하였다. TBA에서의 VAc의 중합 속도는 ADMVN 농도의 0.49승에 비례하였고, 이는 이론치 0.5와 잘 일치하였다. 저온에서 개시가 가능한 ADMVN 및 낮은 사슬이동상수를 갖는 TBA를 사용함으로써 고분자량 및 고수율의 PVA가 얻어졌다. PVAc의 평균 중합도는 전환률 약 35%부터 70%의 범위에서 10000~13000이었고, 이를 비누화하여 얻은 PVA의 평균 중합도는 2400~6100이었다. 교대배열 다이애드기 함량은 중합온도를 낮춤에 따라 조금씩 증가하였고, 중합시 TBA의 입체장애 효과 때문에 TBA의 양을 증가시킴에 따라서도 증가하였다.

  • PDF

The polymerization efficiency of a bulk-fill composite based on matrix-modification technology

  • Elshazly, Tarek M.;Bourauel, Christoph;Aboushelib, Moustafa N.;Sherief, Dalia I.;El-Korashy, Dalia I.
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.32.1-32.12
    • /
    • 2020
  • Objectives: To evaluate the polymerization efficiency of a matrix-modified bulk-fill composite, and compare it to a conventional composite which has a similar filler system. The degree of conversion (DC%) and monomer elution were measured over different storage periods. Additionally, fillers' content was examined. Materials and Methods: Cylindrical specimens were prepared, in bulk and incrementally, from Filtek Bulk Fill (B) and Filtek Supreme XTE (S) composites using a Teflon mold, for each test (n = 6). Using attenuated total reflection method of Fourier transformation infrared spectroscopy, DC% was measured after 24 hours, 7 days, and 30 days. Using high-performance liquid chromatography, elution of hydroxyethyl methacrylate, triethylene glycol dimethacrylate, urethane dimethacrylate, and bisphenol-A glycidyl dimethacrylate was measured after 24 hours, 7 days and 30 days. Filler content was examined by scanning electron microscopy (SEM). Data were analyzed using 2-way mixed-model analysis of variance (α = 0.05). Results: There was no significant difference in DC% over different storage periods between B-bulk and S-incremental. Higher monomer elution was detected significantly from S than B. The elution quantity and rate varied significantly over storage periods and between different monomers. SEM images showed differences in fillers' sizes and agglomeration between both materials. Conclusions: Matrix-modified bulk-fill composites could be packed and cured in bulk with polymerization efficiency similar to conventional composites.

VR애니메이션 <Goodbye Mr Octopus> 연출 연구 (A Study of Direction of VR Animation <Goodbye Mr Octopus>)

  • 이태구;박수경
    • 문화기술의 융합
    • /
    • 제9권1호
    • /
    • pp.135-140
    • /
    • 2023
  • VR애니메이션은 애니메이션 속 공간에 위치하면서 기존 애니메이션 연출에서 볼 수 없는 360도 화면 연출을 볼 수 있다. 2020년에 제작된 VR 애니메이션 <Goodbye Mr Octopus>는 몰입형 단편 영화로 제77회 베니스 영화제에서 선정되었다. 열여섯 번째 생일을 맞은 사춘기 소녀 스텔라와 엄격한 아버지와의 갈등을 어머니의 편지로 해결되는 이야기이다. 총 11개의 씬으로 구성된 서사로 각 씬에는 시선유도, 시간흐름, 공간전환, 외화면 연출 등 VR영상 문법의 새로운 연출적 요소가 분석되었다. 시선유도 연출은 360도 시선의 불편함을 최소화하였으며, 시간 및 공간전환 연출은 서사적 사건에 따른 관객의 몰입도를 높이고, 외화면 연출은 VR공간의 확장 효과로 분석되었다.

무수말레인산으로 그라프트된 폴리에틸렌 왁스의 중합과 가수분해에 대한 연구 (A Study on Synthesis and Hydrolysis of the Maleated Polyethylene Wax)

  • 유시원;최중소;나재식
    • 청정기술
    • /
    • 제19권4호
    • /
    • pp.393-400
    • /
    • 2013
  • 본 연구에서는 고밀도 폴리에틸렌 제조 공정에서의 부산물인 폴리에틸렌 왁스를 대상으로 무수말레인산(MAH)을 도입하여 솔루션 그라프트 반응을 수행 하였고, 반응 효율에 영향을 끼치는 반응 인자들과 MAH 기능기의 가수분해의 영향에 대해서 조사하였다. 측정 결과, MAH 단량체의 농도가 증가 할수록 그라프트 율은 증가하지만, 전환율은 감소하여 MAH 단량체의 농도가 15 wt% 정도에서 최대 효율을 나타냄을 알 수 있었다. DCP (dicumyl peroxide)와 DTBP (di-tert-butyl peroxide)를 개시제로 사용하여 농도에 따라 그라프트 반응한 결과, 약 0.5 wt%에서 그라프트 율이 최대값에 도달함을 볼 수 있었고, 가교반응은 2% 이하의 낮은 수치를 보임을 확인하였다. 반응온도에 따른 그라프트 율은 반응온도가 높아짐에 따라 증가하는 경향을 보이며, 최대 반응시간은 2 h 내외가 됨을 알 수 있었다. 폴리에틸렌 왁스에 그라프트 된 MAH 기능기는 주로 고리열린 상태로 존재하지만 그라프트 율이 5%이상에서는 고리가 닫힌 상태가 생성되었고, 이에 대한 가수분해 측정결과, 언하이드라이드(anhydride)기가 카르복실(carboxylic acid)기로 전환되는 율이 약 10% 정도로 측정되어, 저분자량 폴리에틸렌 왁스(polyethylene wax, PEW)-g-MAH 물성에 영향을 주는 인자로 여겨졌다.

운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성 (Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters)

  • 윤정인;손창효;백승문;김현주;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.580-585
    • /
    • 2012
  • R744용 해양온도차 발전 시스템의 작동변수에 대한 기초 설계자료를 제공하고자 증발열량, 응축열량, 전체일량, 효율에 대한 사이클 성능을 분석하였다. 본 연구에서 고려된 작동변수는 R744 해양온도차 발전 사이클의 과열도, 과냉각도, 응축온도, 증발온도 등이다. 주요 결과를 요약하면 다음과 같다. R744의 증발열량은 과열도와 과냉각도가 증가할수록 증가하는 반면, 응축온도가 증가할수록 감소한다. 전체일량은 R744의 과열도와 과냉각도와 함께 증가하나 증발온도는 증가할수록 감소한다. 그리고 효율은 과열도와 과냉각도가 증가할수록 증가하는 반면, 응축온도는 감소한다. 그러므로 R744용 해양온도차 발전 시스템의 증발열량, 응축열량, 전체일량, 효율은 과열도, 과냉각도, 응축온도, 증발온도, 펌프와 터빈 효율에 영향을 받는 것을 알 수 있었다. 따라서 R744용 해양온도차 발전 시스템의 설계시에는 이러한 영향을 면밀하게 파악하여야 한다.

Bulk-fill 복합레진과 전통적 복합레진의 물성비교 (Comparison of the Mechanical Properties between Bulk-fill and Conventional Composites)

  • 노태환;송은주;박소영;표애리;권용훈;김지연;김신;정태성
    • 대한소아치과학회지
    • /
    • 제43권4호
    • /
    • pp.365-373
    • /
    • 2016
  • 치아우식증을 치료할 때 가장 많이 사용되는 수복재료 중 하나는 레진이다. 하지만 레진은 중합수축, 긴 작업시간, 수분 및 오염에 민감하다는 단점들이 존재하고 어린이를 치료할 때 더 두드러진다. 이러한 단점들을 해결하기 위해 bulk filling이 나타나게 되었고, 이를 가능하게 하는 bulk-fill 복합레진이 개발되었다. 본 연구의 목적은 전통적 복합레진과 bulk-fill 복합레진의 물성을 다양한 방법으로 평가 및 비교하기 위함이다. 전통적 복합레진 3 종류(Filtek Z-350 (Z-350), Unifil Flow (UF), Unifil Loflo Plus (UL)), bulk-fill 복합레진 2종류 (SureFil SDR flow (SDR), Tetric N-Ceram bulk fill (TBF))를 사용하였다. 광중합기는 light-emitting diodes를 사용하였고, 한번 중합할 때 20초간 시행하였다. 재료들의 미세경도는 비커스경도기로 측정하였고, 중합도 측정은 Fourier transform infrared spectroscopy을 사용하였다. 중합수축량은 컴퓨터로 제어되는 linometer를 이용하였다. 굴곡강도 및 굴곡계수는 3점 굽힘 시험법으로 측정하였고, 압축강도 및 압축계수와 함께 Universal testing machine을 이용하여 측정하였다. 통계분석은 ANOVA를 사용하였고, Scheffe의 사후검정을 하였다. 미세경도는 상면에서 Z-350이 가장 높은 값을 나타냈고, 하면은 TBF가 높은 값을 나타냈으나 UL은 상하면 모두에서 가장 낮은 값을 보였다. 상면과 하면의 미세경도 값의 비는 SDR, TBF가 높았다. 중합도는 bulk-fill 복합레진과 유동성 복합레진 상하면 모두에서 높게 나타나고, Z-350는 상하면 모두에서 55% 이하로 나타났다. 압축강도는 Z-350이 가장 높았으며 SDR이 낮게 나타났으나 UL과는 통계학적으로 유의하게 차이는 보이지 않았다. 압축계수는 Z-350이 높게 나타났고, UL이 가장 낮았다. 굴곡강도 및 굴곡계수는 Z-350이 가장 높았다. UL은 굴곡강도 및 굴곡계수 모두 가장 낮게 나타났다. UL이 가장 높은 중합수축을 보였고, Z-350이 가장 낮은 중합수축 값을 나타냈다. 유동성 복합레진이 비유동성 복합레진보다 중합 수축 양이 많았다. 결론적으로 bulk-fill 복합레진의 물성은 전통적 복합레진보다 떨어지지만 bulk filling할 때 중요한 상하면의 미세경도비 및 중합도는 높게 나타나 어린이의 치아우식증 수복치료 시 도움이 될 수 있을 것으로 사료된다.