• Title/Summary/Keyword: degree of alignment

Search Result 196, Processing Time 0.024 seconds

A Wafer Alignment Method and Accuracy Evaluation (웨이퍼 정렬법과 정밀도 평가)

  • Park, Hong-Lae;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.9
    • /
    • pp.812-817
    • /
    • 2002
  • This paper presents a development of high accuracy aligner and describes a method to find the orientation of a substantially circular disk shaped wafer with at least one flat region on an edge thereof. In the developed system, the wafer is spun one 360 degree turn on a chuck and the edge position is measured by a linear array to obtain a set of data points at various wafer orientation. The rotation axis may differ from wafer center by an unknown eccentricity. The flat angle is found by fitting a cosine curve to the actual data to obtain a deviation. The maximum deviation is then corrected for errors due to a finite number of data points and wafer eccentricity by calculating an adjustment angle from data points on the wafer fiat. After determining the flat angle the wafer is spun to the desired orientation. The wafer eccentricity can be calculated from four of the data points located away from the flat edge region. and the wafer is then centered.

접촉식 측정시스템에 의한 공작물의 자동인식 및 오차보상

  • 신동수;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.121-125
    • /
    • 1991
  • In order to minimize fixing error of workpieces, prismatic and cylindrical types. Modification Rule by Indexing Table and Modification Rule by NC Program are developed for machining centers by using touch trigger probes. The Modification Rule by Indexing Table means the alignment of workpiece to NC program through degree of freedoms of indexing table. The Modification Rule by NC Program is the alignment of NC program to workpiece set-up condition via the generation of NC program. A postprocessing module is also developed for generating NC-part Program (User Macro) to compensate for Machining errors in end milling and boring processes. Developed methods are verified by experiments.

  • PDF

PVA Technology for High Performance LCD Monitors

  • Kim, Kyung-Hyun;Song, Jang-Geun;Park, Seung-Bam;Lyu, Jae-Jin;Souk, Jun-Hyung;Lee, Khe-Hyun
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.3-8
    • /
    • 2000
  • We have developed a high performance vertical alignment TFT-LCD (Thin Film Transistor Liquid Crystal Display), that shows a high light transmittance, and wide viewing angle characteristics with an unusually high contrast ratio. In order to optimize the electro-optical properties we have studied the effect of cell parameters, multi-domain structure and retardation film compensation. With the optimized cell parameters and process conditions, we have achieved a 24" wide UXGA TFTLCD monitor (16:10 aspect ratio 1920X1200) showing a contrast ratio of over 500:1, panel transmittance near 4.5%, response time near 25 ms, and viewing angle higher than 80 degree in all directions.

  • PDF

The Analysis of Road Alignement and Construction GSIS Using RTK GPS and TS (RTK-GPS와 TS를 이용한 도로선형분석 및 GSIS 구축)

  • 장상규;홍순헌;김가야
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.4
    • /
    • pp.293-299
    • /
    • 2003
  • In the future, the design of road should be convenient in using of high-technology information and it needs the design of alignment that is able to make the maximum vehicles inducement function appropriated for CNS(Car Navigation System). So it needs to analysis appropriately the alignment of road for the improvement design of road which is established and to make the design of road and the coordinate of the main points. Therefore, this research had acquired the road data by RTK-GPS to accurate the analysis of road alignment and compared with Total Station. As the result, we could acquire the design source of the road alignment using RTK-GPS. Also, it was estimated the accuracy after comparing the design with RTK-GPS coordinates. We made an analysis of the degree of slant or the ups and downs of surface. We made an analysis of three dimensional visual information which was included in GSIS concept and estimated the accuracy. Finally, we analyzed the earth volume calculation by comparing with Total Station.

The alignment of Sr-ferrite magnetic powder in anisotropic Sr-ferrite/resin-bonded magnets (이방성 Sr-페라이트/ 레진본드 영구자석에서 Sr-페라이트 자성분말의 방향성)

  • 정원용;조태식;문탁진
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.3
    • /
    • pp.219-225
    • /
    • 1994
  • The alignment of Sr-ferrite magnetic powders, which is usually related to the fluidity and the applied magnetic field, is investicated in the anisotropic Sr-ferrite / resin-bonded permanent magnets. The magnetic powder alignment is observed to increase with the applied magnetic field and the fluidity which is a function of molding temperature and powder packing ratio. The best magnetic powder alignment is achieved at the following conditions; Sr-ferrite packing ratio of 56vol%, apparent viscosity of about 3000 poise in $1000sec^{-1}$ shear rate, and applied magnetic field of about 5kOe. The degree of preferred orientation of the magnetic powders in the field direction, as determined by the dc hysterisis graphs, is 84~85% (0.84~0.85). This result is in agreement with the value of 0.85 obtained by the X-ray experiments in the $2{\theta}$ range of ${23~40}^0$. The best magnetic properties obtained are:2.2kG of remanent flux density, 2.2MGOe of maximum energy product.

  • PDF

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

Designed tire wear and uneven wear determination system using only tire laser sensor (타이어 전용 레이저 센서를 이용한 타이어 마모도 및 편마모 판별 시스템 설계)

  • baek, Sung-hyun;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.346-349
    • /
    • 2015
  • Generally, in order to verify the degree of tire wear or abnormal wear, a driver or an auto mechanic checks the degree of tire wear and the existence of tire abnormality, directly with the naked eye or by way of using a gauge equipment. In case of such verification, individual subjective judgments may be involved or a driver may suffer heavy burdens to expend the time and cost for using the wheel alignment equipment. Therefore, this thesis will use a number of laser sensors to check the existence of abnormal wear and the degree of wear on each tire and develop a system checking the sides of tires to receive the tire information, so that subjective judgments may be overcome and objective and accurate judgments may be rendered.

  • PDF

On the machine error measurement and compensation (NC 공정기계에서 온더머신 오차측정 및 보상)

  • 신동수;정성종
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.1096-1101
    • /
    • 1992
  • In order tominimize fixing error of workpieces, circle, prismatic, sphere, cylindrical and sculptures types. Modification Rule by Indexing Table and Modification Rule by NC Program are developed for machining centers by using touch trigger probes. The Modification Rule by Indexing Table meas the alignment of workpiece to NC program through degree of freedoms of indexing table. The Modification Rule by NC Program is the alognment of NC program to workpiece ste-tp condition via the generation of NC progarm. A postprocessing module is alos developed for generating NC-part program(User Macro) to compensate for machining errors in end milling and boring processes. Developed method are verified by experiments.

  • PDF

Two-way Viewing Angle Switchable LCD with Two-Domain VA Structure

  • Preman, Smarty P.;Chen, Chao Ping;Yoon, Tae-Hoon;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.898-899
    • /
    • 2008
  • In this paper we propose a new method for obtaining two way switchable LCD. For this two domain vertical alignment LCD is used. A two way LCD is able to show different images on the same screen based on left and right perspectives. Viewing angle dependence of different grey levels of transmittance for the polar angles 0, +45 and -45 degree are also found out.

  • PDF

Development of Polarization Controlled Micro Transmittance Profiler

  • An, Sung-Hyuck;Kim, Sang-Jun;Kim, Sang-Youl
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.998-1000
    • /
    • 2005
  • We report the development of the equipment that can measure the transmittance of the polarizer for TFTLCD application versus azimuth angle of the linear polarization at each micro spot in the section, and therefore measure the degree of iodine permeation and alignment quantitatively at each area of the section.

  • PDF