• Title/Summary/Keyword: degradation process

Search Result 1,977, Processing Time 0.03 seconds

Sequential microbial-photocatalytic degradation of imidacloprid

  • Sharma, Teena;Kaur, Manpreet;Sobti, Amit;Rajor, Anita;Toor, Amrit Pal
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.597-604
    • /
    • 2020
  • In the present study, the application of sequential biological and photocatalytic process was evaluated as a feasible process for the degradation of imidacloprid (IMI) in soil. Photocatalysis was carried out as a post and pre-treatment to the biological process as Microbial Photocatalytic (MP) and Photocatalytic Microbial (PM), respectively, to enhance the degradation and mineralization of IMI in soil. By both the processes, there was an enhancement in the percentage degradation of IMI i.e 86.2% for PM and 94.6% for MP process. The obtained results indicate that MP process is apparently more efficient in degradation of IMI which was observed with 15 days of biological treatment followed by 18 h of photocatalytic degradation (15 d + 18 h). The present work also reveals that though the difference in terms of the degradation of IMI after 5 d + 18 h, 10 d + 18 h & 15 d+ 18 h of MP process is not drastic, yet significant variation has been observed in terms of mineralization that truly signifies the removal of IMI from the soil. The LC analysis has shown that the intermediates formed during MP process are more and smaller in comparison to PM process, which further provides evidence that MP process is better than PM process for effective degradation of IMI in soil.

Thermal Degradation of Aqueous MEA Solution for CO2 Absorption by Nuclear Magnetics Resonance (핵자기공명분석법을 이용한 수용성 아민 CO2 흡수제인 MEA의 열적변성 분석)

  • CHOI, JEONGHO;YOON, YEOIL;PARK, SUNGYOUL;BAEK, ILHYUN;KIM, YOUNGEUN;NAM, SUNGCHAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.562-570
    • /
    • 2016
  • At the carbon dioxide capture process using the aqueous amine solution, degradation of absorbents is main factor to reducing the process performance. Also, degradation mechanism of absorbent is important for understanding the environmental risk, route of degradation products, health risk etc. In this study, the degradation products of MEA were studied to clarify mechanism in thermal degradation process. The degradation products were analyzed using a $^1H$ NMR (nuclear magnetic resonance) and $^{13}C$ NMR. The analysis methods used in this study provide guidelines that could be used to develop a degradation inhibitor of absorbent and a corrosion inhibitor.

Planning Accelerated Degradation Tests: the Case of Gamma Degradation Process (열화가 감마과정을 따르는 경우 가속열화시험의 최적 계획)

  • Lim, Heonsang;Lim, Dae-Eun
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.2
    • /
    • pp.169-184
    • /
    • 2015
  • Purpose: This paper is concerned with optimally designing accelerated degradation test (ADT) plans based on a gamma process for the degradation model. Methods: By minimizing the asymptotic variance of the MLE of the q-th quantile of the lifetime distribution at the use condition, the test stress levels and the proportion of test units allocated to each stress level are optimally determined. Results: The optimal plans of ADT are developed for various combination of parameters. In addition, a method for determining the sample size is developed, and sensitivity analysis procedures are illustrated with an example. Conclusion: It is important to optimally design ADT based on a gamma process under the condition that a degradation process should be always nonnegative and strictly increasing over time.

The Study of Degradation Mechanism as ZnO Varistor with The Ambient Sintering-Process (분위기 소결공정에 의한 ZnO 바리스터의 열화기구 연구)

  • 소순진;김영진;최운식;박춘배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.117-120
    • /
    • 1999
  • The relationship between the DC degradation characteristics of the ZnO varistor and the ambient sintering-process is investigated in this study. ZnO varistors made of Matsuoka's composition were fabricated by standard ceramic techniques. The ambient sintering-process is performed at the extraordinary electrical-furnace which is equipped with the vacuum system. The Gas of sintering process was oxygen, nitrogen, argon, air respectively. The microstructure of ZnO varistors be made use of SEM equipment. The condition of DC degradation tests were conducted at $115\pm2^{\circ}C$ for periods up to 13 h. Current-voltage analysis is used to determine nonlinear coefficients($\alpha$). Resistance-frequency and capacitance-frequency analysis are accomplished to the understanding of electrical properties as DC degradation test. From above analysis, it is found that the ZnO varistor sintered in oxygen atmosphere showed superior properties at the DC degradation test.

  • PDF

A Study on the Degradation Mechanism of ZnO Ceramic Varistor Manufactured by Ambient Sintering-Process (분위기 소결공정에 의해 제조된 ZnO 세라믹 바리스터의 열화기구 연구)

  • 소순진;김영진;박춘배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.5
    • /
    • pp.383-389
    • /
    • 2000
  • The relationship between the DC degradation characteristics of the ZnO varistor and the ambient sintering-process is investigated in this study. ZnO varistors made o matsuoka’s composition were fabricated by standard ceramic techniques. The ambient sintering-process is performed at the extraordinary electrical-furnace which is equipped with the vacuum system. Gases used in sintering process were oxygen nitrogen argon and air. Using XRD and SEM the phase and microstructure of samples were analyzed respectively. The conditions of DC degradation tests were conducted at 115$\pm$2$^{\circ}C$ for 13 h. Current-voltage analysis is used to determine nonlinear coefficients($\alpha$). Frequency analysis are performed to understand electrical properties as DC degradation test. From above analysis it is found that the ZnO varistor sintered in oxygen atmosphere showed superior properties at the DC degradation test and degradation phenomenon of ZnO varistor is caused by the change of electrical properties in grain boundary. These results are in accordance with Gupta’s degradation model.

  • PDF

Degradation of 2-Chlorophenol in the Aqueous Phase by a Photo-Fenton Process (광펜톤 반응에 의한 수중 2-클로로페놀 분해특성연구)

  • Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.779-786
    • /
    • 2012
  • The degradation of 2-chlorophenol(2-CP) by various AOPs(Advanced Oxidation Processes) including the photo-Fenton process has been examined. In sole $Fe^{2+}$, UV or $H_2O_2$ process without combination, low removal efficiencies have been achieved. But the photo-Fenton process showed higher removal efficiency for degradation of 2-chlorophenol than those of other AOPs including the Fenton process and the UV processes. In the photo-Fenton process, the optimal experimental conditions of 2-chlorophenol degradation were obtained at pH 3 and the $Fe^{2+}/H_2O_2$molar ratio of 1. Also the 2-chlorophenol removal efficiency increased with decreasing of the initial 2-chlorophenol concentration. 3-chlorocatechol and chlorohydroquinone were identified as photo-Fenton reaction intermediates, and a degradation pathway of 2-chlorophenol in the aqueous phase during the photo-Fenton reaction was proposed.

Degradation of 4-Chlorophenol by a Photo-Fenton Process with Continuous Feeding of Hydrogen Peroxide (과산화수소 연속주입식 광펜톤산화공정에 의한 4-염화페놀 분해연구)

  • Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The degradation of 4-chlorophenol(4-CP) by various AOPs(Advanced Oxidation Processes) with continuous feeding of $H_2O_2$, including the ultraviolet/hydrogen peroxide, the Fenton and the photo-Fenton process has been investigated. The photo-Fenton process showed the highest removal efficiency for degradation of 4-chlorophenol than those of other AOPs including the Fenton process and the combined UV process with continuous feeding of $H_2O_2$. In the photo-Fenton process, the optimal experimental condition for 4-CP degradation was obtained at pH 3. Also the 4-CP removal efficiency increased with decreasing of the initial 4-CP concentration. 4-chlorocatechol and 4-chlororesorcinol were identified as photo-Fenton reaction intermediates, and the degradation pathways of 4-CP in the aqueous phase during the photo-Fenton reaction were proposed.

The Evaluation of Degradation Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring (누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가)

  • Kim, Jeong-Ho;Song, Woo-Chang;Cho, Han-Goo;Park, Yong-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.60-64
    • /
    • 2001
  • The degradation process of silicone rubber was investigated by leakage current monitoring in Inclined-Plane method. DAS (Data Acquisition System) with 12-bit, 8-channel A/D converter was prepared. Average current, cumulative charge, current waveform and the number of peak pulses were measured on-line. And, FFT (Fast Fourier Transform) analysis was performed with stored current waveform. Besides, maximum erosion depth was measured in order to use as the indicator of the degradation process. So, the results of leakage current components and maximum erosion depth measurements were compared to find one or more components which have trends of changing similarly to that of erosion process. The result suggests that the ratio of peak current to r.m.s. current, harmonic contents and the number of peak pulses are well corresponding with the degradation process.

  • PDF

Degradation Of 4-chlorophenol By Photo-Fenton Process and Fenton Process in Aqueous Solutions (광펜톤반응과 펜톤반응에 의한 수중 클로로페놀 분해비교연구)

  • Kim, Hyun-Seung;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.463-469
    • /
    • 2011
  • The degradation of 4-chlorophenol by various AOPs(Advanced Oxidation Processes) including the Fenton and the photo-Fenton process has been examined. In sole Fe, UV or $H_2O_2$ process without combination, low removal efficiencies have been achieved. But the photo-Fenton process showed higher removal efficiency for degradation of 4-chlorophenol than those of other AOPs including the Fenton process. Generally more hydrogen peroxide was required to achieve higher removal efficiencies of 4-CP at constant dosage of $FeSO_4$ in both of the Fenton and the photo-Fenton processes. Based on the results, The photo-Fenton process is proposed to be the most efficient alternative for degradation of 4-chlorophenol among the processes studied in this research.

Photocatalytic and Sonophotocatalytic degradation of alachlor using different photocatalyst

  • Bagal, Manisha V.;Gogate, Parag R.
    • Advances in environmental research
    • /
    • v.2 no.4
    • /
    • pp.261-277
    • /
    • 2013
  • The degradation of alachlor has been investigated using sonolysis (US), photocatalysis (UV) and sonophotocatalysis (US/UV) using three photocatalyst viz. $TiO_2$ (mixture of anatase and rutile), $TiO_2$ (anatase) and ZnO. The effect of photocatalyst loading on the extent of degradation of alachlor has been investigated by varying $TiO_2$ (both types) loading over the range of 0.01 g/L to 0.1 g/L and ZnO loading over the range of 0.05 g/L to 0.3 g/L. The optimum loading of the catalyst was found to be dependent on the type of operation i.e., photocatalysis alone or the combined operation of sonolysis and photocatalysis. All the combined processes gave complete degradation of alachlor with maximum rate of degradation being obtained in the case of sonophotocatalytic process also showing synergistic effect at optimized loading of photocatalyst. About 50% to 60% reduction in TOC has been obtained using the combined process of sonophotocatalysis depending on the operating conditions. The alachlor degradation fitted first order kinetics for all the processes under investigation. It has been observed that the $TiO_2$ (mixtrure of anatase and rutile) is the most active photocatalyst among the three photocatalysts studied in the current work. The effect of addition of radical enhancers and scavengers on sonophotocatalytic degradation of alachlor has been investigated in order to decipher the controlling mechanism. The alachlor degradation products have been identified using LC-MS method.