• Title/Summary/Keyword: degradation pattern

Search Result 449, Processing Time 0.029 seconds

Degradation Pattern and Rate of Some Pesticides in Soils -Part I. Degradation Pattern and Rate of Parathion in Soils- (토양처리(土壤處理) 농약제(農藥劑)의 분해율(分解率)에 관한 연구(硏究) -제1보(第一報). Parathion의 토양중(土壤中) 분해(分解)에 대하여-)

  • Lim, Sun-Uk;Kang, Kyu-Yung;Choi, Yong-Lak
    • Applied Biological Chemistry
    • /
    • v.26 no.4
    • /
    • pp.239-247
    • /
    • 1983
  • The effects of some soil conditions on the degradation rate and decomposing pattern of parathion were investigated and the obtained results are summarized as follows: Parathion degraded more rapidly in flooded soils than in non-flooded, in wet soils than in dry soils under non-flooded soils. The degradation rates in paddy and upland soils increased at high temperature than low temperature, higher pesticide concentration than low concentration and higher soil pH level. Parathion in paddy and upland soils was more persistent under soil sterilization than under non-sterilization and degraded rapidly in glucose application. Parathion was more persistent in upland soils than paddy soils under several factors described above. The metabolites identified from the paddy and upland soils by TLC include para-oxon (Rf 0.5), aminoparathion(Rf 0.27), p-nitrophenol(Rf 0.2), p-aminophenol(Rf 0.15). Soil enzyme, acid phosphatase activities decreased more at flooded soils than non-flooded, higher pesticide concentration than low concentration and higher soil pH level and the activity in glucose application was increased. Soil enzymes, urease and dehydrogenase activity decreased more at higher pesticide concentration than low concentration. Comparing with soil enzyme activity in paddy and upland soil, the former was higher than the latter.

  • PDF

Adsorption-Desorption, Leaching, and Degradation Pattern of Fungicide Fluazinam in the Soil Environment (살균제 Fluazinam의 토양환경 중 흡.탈착, 용탈 및 분해양상)

  • Hu, Won;Lee, Seog-June;Kim, Jang-Eok
    • Applied Biological Chemistry
    • /
    • v.40 no.2
    • /
    • pp.128-133
    • /
    • 1997
  • This study was conducted to evaluate the adsorption, desorption, leaching and degradation pattern of fungicide fluazinam in the soil environment under the laboratory conditions. The mode of isothermal adsorption of fluazinam in soil was coincident with the Freundlich equation. The adsorption amount of fluazinam was much higher on soils containing organic matter than on soils oxidized with hydrogen peroxide. The presence of organic matter, humic acid or fulvic acid, increased the adsorption amount of fluazinam on soils. The Freundlich constant K was much higher in soil added with humic acid than in soil added with fulvic acid. The desorption ratio of fluazinam adsorbed to soil was increased by removal of organic matter. In leaching experiment using soil column, the fluazinam applied on the soil surface was not moved down to the bottom of soil and was not detected in leachate water. The degradation of fluazinam was faster in Soil I with rich organic matter than Soil II with poor organic matter, in non-sterilized soil than sterilized soil, and in flooded soil than unflooded soil.

  • PDF

The Study on Respiratory Function, Spirometric Lung Pattern and Fatigue of Elderly in a Facility

  • Shin, Hee Joon;Kim, Ji Sung;Wang, Joong San;Choi, Yoo Rim;Kim, Hong Rae;Park, Si Eun;An, Ho Jung;Min, Kyung Ok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.1
    • /
    • pp.488-493
    • /
    • 2013
  • The purpose of this study was to investigate spirometric lung pattern, respiratory function and degree of fatigue by lung function tests and fatigue tests of 39 elderly people in a care facility aged 65 and over. The respiratory function tests were used to the Spirovit SP-1 and fatigue tests were used modified Piper fatigue scale(mPFS). Regarding the respiratory function, the FVC was $1.41{\pm}0.36$l, the FVC % predicted was $69.10{\pm}14.98$%, the $FEV_1$ was $1.02{\pm}0.31$l, the $FEV_1$ % predicted was $63.27{\pm}16.05$%, the $FEV_1$/FVC was $72.77{\pm}13.40$%, and the fatigue score was $5.83{\pm}1.09$. As for the spirometric lung pattern, 19 patients had a restrictive pattern(48.7%), followed by 11 with a mixed pattern(28.2%), 5 with an obstructive pattern( 12.8%), and 4 with a normal pattern(10.3%). Regarding the respiratory function and fatigue by spirometric lung pattern, the FVC and the FVC % predicted of patients with a normal pattern or an obstructive pattern were greater than other groups at a statistically significant level. As for the $FEV_1$, that of patients with a normal pattern was significantly higher than others, and for the $FEV_1$ % predicted, that of patients with a normal pattern or a restrictive pattern was significantly higher(p<.001). Fatigue score by patients with a normal pattern was significantly less than patients of other patterns(p<.001). Therefore, pulmonary physical therapy is considered necessary to improve respiratory function and fatigue degradation of elderly in a facility.

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill (전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정)

  • Kim, Hyeng-Gyun;Joung, Ki-Bong;Go, Seok-Man;Oh, Moo-Song;Kim, Teh-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF

Residual Pattern of Procymidone and Chlorothalonil in Grape During the Period of Cultivation and Storage (포도의 재배 및 저장기간 중의 Procymidone 및 Chlorothalonil의 잔류량변화)

  • Ko, Kwang-Yong;Kim, Kum-Hee;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.1
    • /
    • pp.47-51
    • /
    • 2004
  • In order to know the residual pattern of pesticides and predict to the degradation period until below MRL we experimented procymidone and chlorothalonil for grape which were the most detected pesticide in grape by NAQS(National Agricultural product Quality management Service) survey. In this experiment we sprayed those pesticides 10 days before harvest and analyzed 0, 1, 2, 3, 5, 7, 10 day sample to establish logical equation and to calculate $DT_{50}$. Also the same day samples stored at $4^{\circ}C$ and $20^{\circ}C$, which were compared their degradation patterns. During the cultivating period, the residue amount of procymidone was changed from 1.85 mg/kg (0 day) to 0.33 mg/kg (10 day), $DT_{50}$ was 3.5 days, and chlorothalonil was changed from 5.5 mg/kg (0 day) to 3.49 mg/kg (10 day), $DT_{50}$ was 4.4 days. During the storage period, $DT_{50}$ of procymidone and chlorothalonil at $4^{\circ}C$ were 10.5 and 7.6 days, and 6.3 and 6.1 days at $20^{\circ}C$, respectively.

HFPD Characteristic Analysis of Simulated Transformer According To Applied Voltage (인가전압에 따른 모의변압기의 HFPD 특성분석)

  • Kim, Duck-Keun;Im, Young-Sham;Lim, Jang-Seob;Moon, Chae-Joo;Lee, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1957-1959
    • /
    • 2000
  • The PD measurement method is very useful to detect insulation degradation. Recently, the HFPD(High Frequency Partial Discharge) measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires in-service diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In this study, simulated transformer is manufactured and HFPD occurred from simulated transformer is measured with broad band antenna and active-line RF measurement system in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages. Also the PD pattern which was measured with EMC analyzer and RF measurement system is compared.

  • PDF

Hydrothermal Synthesis of Cubic Mesocrystal CeO2 for Visible Photocatalytic Degradation of Rhodamine B

  • Yang, Hexiang;Zhou, Mengkai;Meng, Zeda;Zhu, Lei;Chen, Zhigang;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.25 no.3
    • /
    • pp.144-148
    • /
    • 2015
  • Cubic mesocrystal $CeO_2$ was synthesized via a hydrothermal method with glutamic acid ($C_5H_9NO_4$) as a template. The XRD pattern of a calcined sample shows the face-centered cubic fluorite structure of ceria. Transmission electron microscopy (TEM) and the selected-area electron diffraction (SAED) pattern revealed that the submicron cubic mesocrystals were composed of many small crystals attached to each other with the same orientation. The UV-visible adsorption spectrum exhibited the red-shift phenomenon of mesocrystal $CeO_2$ compared to commercial $CeO_2$ particles; thus, the prepared materials show tremendous potential to degrade organic dyes under visible light illumination. With a concentration of a rhodamine B solution of 20 mg/L and a catalyst amount of 0.1 g/L, the reaction showed higher photocatalytic performance following irradiation with a xenon lamp (${\geq}380nm$). The decoloring rate can exceed 100% after 300 min.

Analysis of X-Band Link Performance Degradation Caused by Adjacent Satellite

  • Park, Durk-Jong;Ahn, Sang-Il;Chun, Yong-Sik;Kim, Eun-Kyou
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • As more satellites are designed to downlink their observed image data through the X-band frequency band, it is inevitable that the occupied bandwidth of a target satellite will overlap with that of other X-band downlink satellites. For sun-synchronized low earth orbit satellites, in particular, it can be expected that two or more satellites be placed within the looking angle of a ground station antenna at the same time. Due to the overlapping in the frequency band, signals transmitted from the adjacent satellites act as interferers, leading to degraded link performance between target satellite and ground station. In this paper, link analysis was initiated by modeling the radiation pattern of ground station antenna through a validated Jet Propulsion Laboratory peak envelope model. From the relative antenna gain depending on the offset angle from center axis of maximum antenna directivity, the ratio of received interference signal level to the target signal level was calculated. As a result, it was found that the degradation increased when the offset angle was within the first point of radiation pattern. For a 7.3 m antenna, serious link degradation began at an offset angle of 0.4 degrees. From this analysis, the link performance of the coming satellite passes can be recognized, which is helpful to establish an operating procedure that will prevent the ground station from receiving corrupted image data in the event of a degraded link.

Influence of Controlling Protozoa on the Degradation and Utilization of Dietary Fibre and Protein in the Rumen and Nitrogenous Flow Entering the Duodenum of Sheep

  • Han, C.Y.;Lu, D.X.;Hu, M.;Tan, Z.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1241-1245
    • /
    • 1999
  • Nine two-year old sheep fitted with rumen and duodenum cannulas were used to study the effect of controlling protozoa flora on the degradation and utilization of dietary fibre and protein in the rumen and on nitrogenous flow to the duodenum. There were three groups in this experiment: defaunation (DF); partial defaunation (PDF); faunation (F) as control. Results showed that: 1,There were no differences between treatments in dietary DM degradation in the rumen, but defaunation and partial defaunation increased the quantity of nitrogenous material in the rumen and the flow of N to duodenum. 2, partial defaunation and defaunation improved the degradabilities of dietary NDF, ADF and HC, but there were no differences between the defaunated and partially defaunated groups. 3, Partial defaunation decreased the degradability of dietary protein in the rumen. There was no difference between defaunated and faunated groups. 4, Defaunation and partial defaunation increased the quantity of total N (TN) and microbial N (MCN) in the rumen and the amounts entering the duodenum. The protozoa N (PN) flow in the faunated group was higher than that in the partially defaunated group, and the amino acid pattern in the digesta at the proximal duodenum in the defaunated group was closer to the ideal amino acid pattern. 5, There were differences in the mole percent of acetic, propionic, total-VFAs and the non-glucogenic to glucogenic VFAs ratio (NGR) value in the rumen fluids. The order was as follows: mole percent of acetate: F>PDF>DF; mole percent of propionate: DF>PDF>F; total-VFAs: PDF>F>DF; NGR: F>PDF>DF.