• 제목/요약/키워드: defects type

검색결과 995건 처리시간 0.026초

Surgical implications of anatomical variation in anterolateral thigh flaps for the reconstruction of oral and maxillofacial soft tissue defects: focus on perforators and pedicles

  • Kim, Ji-Wan;Kim, Dong-Young;Ahn, Kang-Min;Lee, Jee-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권5호
    • /
    • pp.265-270
    • /
    • 2016
  • Objectives: To gain information on anatomical variation in anterolateral thigh (ALT) flaps in a series of clinical cases, with special focus on perforators and pedicles, for potential use in reconstruction of oral and maxillofacial soft tissue defects. Materials and Methods: Eight patients who underwent microvascular reconstructive surgery with ALT free flaps after ablative surgery for oral cancer were included. The number of perforators included in cutaneous flaps, location of perforators (septocutaneous or musculocutaneous), and the course of vascular pedicles were intraoperatively investigated. Results: Four cases with a single perforator and four cases with multiple perforators were included in the ALT flap designed along the line from anterior superior iliac spine to patella. Three cases had perforators running the septum between the vastus lateralis and rectus femoris muscle (septocutaneous type), and five cases had perforators running in the vastus lateralis muscle (musculocutaneous type). Regarding the course of vascular pedicles, five cases were derived from the descending branch of the lateral circumflex femoral artery (type I), and three cases were from the transverse branch (type II). Conclusion: Anatomical variation affecting the distribution of perforators and the course of pedicles might prevent use of an ALT free flap in various reconstruction cases. However, these issues can be overcome with an understanding of anatomical variation and meticulous surgical dissection. ALT free flaps are considered reliable options for reconstruction of soft tissue defects of the oral and maxillofacial area.

고체내부에 존재하는 결함의 형태에 따른 초음파 신호의 특징 추출 (Feature Extraction of Ultrasonic Signal due to Form of Defect in Solids)

  • 문상택
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1993년도 학술논문발표회 논문집 제12권 1호
    • /
    • pp.169-173
    • /
    • 1993
  • In this paper, the features extraction of reflected signals from various type of defects existing in the solid has been studied by Wiener filtering technique. In this experiment, three types of the defect have been considered; a flat cut, a angular cut and a circular hole. All of the defects have the same size, 20mm in diameter and have been located at 45mm in depth from the aluminum surface. In the result of the experiment, it has been found that the wiener filtering technique used for features extraction from the reflected signal corresponding to each defect have been very effective for defect classification.

  • PDF

산업용Wire Harness Vision 검사 장비 개발 (Development of Vision Inspection System for Defects of Industrial Wire Harness)

  • 한승철
    • 한국산업융합학회 논문집
    • /
    • 제11권4호
    • /
    • pp.189-194
    • /
    • 2008
  • This paper presents vision based inspection system for defects of industrial wire harness. Five type of nonconformities facter such as barrel deform, projected wire, overcoating, rack of wire length, over-strip is considered. Developed inspectio algorithmn has been tested on real specimens from a wire harness factory. Experimental results show that the inspection algorithm an has a good performance.

  • PDF

다중결함에 의한 부분방전 패턴특성 (PD Characteristics of Multi-Defects System)

  • 이준호;이철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2411-2413
    • /
    • 1999
  • Regarding the application of diagnistic technology using PD signal to power apparatus, it is necessary to discriminate the type of defect as well as to determine whether the PD occurs or not. In this research, PD characteristics of multi-defects insulating system were presented, the PD signals were detected from three kinds of electrode systems, IEC(b), needle-plane and CIGRE method II. To make multi-defect systems artificially, we combined three electrode systems and applied same test voltage simultaneously.

  • PDF

공동주택 하자소송단계에서의 하자인정항목에 관한 연구 (A Study on the Newly Recognized Defect Factors in Defect Lawsuits of Apartment Housing)

  • 고영태;신윤석;이명도
    • 한국건축시공학회지
    • /
    • 제20권6호
    • /
    • pp.567-576
    • /
    • 2020
  • 본 연구는 공동주택의 하자소송의 사례분석을 통해 하자소송단계에서 추가적으로 하자로 인정되는 하자 항목을 제안한다. 이 하자 항목은 하자소송에서 추가적인 비용의 증가, 일정 지연, 재감정 혹은 추가소송을 방지할 수 있을 것이다. 하자소송에서는 입주자 및 건설사에서 사전에 인지하지 못한 새로운 하자항목이 발생되며, 이를 새로운 하자인정항목으로 정의하였다. 이를 위해 본 연구에서는 국내의 15개의 하자소송의 사례분석을 실시하였다. 이를 통해 77개의 소송하자를 1차 선별하고 전문가 자문을 통해 최종적으로 23개의 소송하자를 도출하였다. 이후 하자의 요인을 분석하여 최종적으로 23개의 소송항목을 총 10개의 요인항목으로 정립하였으며, 사례연구를 통해 효용성을 분석하였다. 본 연구의 결과는 하자의 발생을 저감하고 분쟁을 최소화하는 데 기여할 수 있을 것이다.

양성자 조사가 316 스테인리스강의 미세조직과 표면산화 특성에 미치는 영향 (Effects of Proton Irradiation on the Microstructure and Surface Oxidation Characteristics of Type 316 Stainless Steel)

  • 임연수;김동진;황성식;최민재;조성환
    • Corrosion Science and Technology
    • /
    • 제20권3호
    • /
    • pp.158-168
    • /
    • 2021
  • Austenitic 316 stainless steel was irradiated with protons accelerated by an energy of 2 MeV at 360 ℃, the various defects induced by this proton irradiation were characterized with microscopic equipment. In our observations irradiation defects such as dislocations and micro-voids were clearly revealed. The typical irradiation defects observed differed according to depth, indicating the evolution of irradiation defects follows the characteristics of radiation damage profiles that depend on depth. Surface oxidation tests were conducted under the simulated primary water conditions of a pressurized water reactor (PWR) to understand the role irradiation defects play in surface oxidation behavior and also to investigate the resultant irradiation assisted stress corrosion cracking (IASCC) susceptibility that occurs after exposure to PWR primary water. We found that Cr and Fe became depleted while Ni was enriched at the grain boundary beneath the surface oxidation layer both in the non-irradiated and proton-irradiated specimens. However, the degree of Cr/Fe depletion and Ni enrichment was much higher in the proton-irradiated sample than in the non-irradiated one owing to radiation-induced segregation and the irradiation defects. The microstructural and microchemical changes induced by proton irradiation all appear to significantly increase the susceptibility of austenitic 316 stainless steel to IASCC.

다양한 형태의 금속 산화물을 이용한 Pd계 복합 수소분리막의 2원계 중간층 형성에 관한 연구 (A Study of the Formation of Binary Intermediate Layer on Pd-based Hydrogen Separation Membrane Using Various Types of Metal Oxides)

  • 황인혁;김성수
    • 공업화학
    • /
    • 제29권2호
    • /
    • pp.196-200
    • /
    • 2018
  • 본 연구에서는 복합 수소분리막 중간층의 pin hole, crack 및 defect를 최소화하기 위하여 powder type과 sol type의 금속산화물을 이용하여 복합화하였다. 중간층의 표면 형상과 투과 특성은 주사전자현미경(SEM) 분석과 $N_2$ 투과도 테스트를 통해 평가하였으며, 제조한 수소분리막의 성능평가를 위해 $N_2$$H_2$를 이용하여 단일가스 투과 테스트를 수행하였다. Powder type과 sol type의 금속산화물을 각각 이용하여 중간층을 적층한 결과 sol type 금속산화물을 이용하여 적층한 중간층의 표면 조도가 매우 낮았으며, 특히 $TiO_2$ sol로 형성된 중간층의 pin-hole, crack 및 defect가 현저히 감소하였다. Powder와 sol을 복합화하여 적층한 중간층은 sol로 형성된 중간층과 거의 유사한 특성을 보였으며, 이를 기반으로 제조한 수소분리막은 1 bar의 압력구배, 672 K의 온도에서 약 $0.32mol/m^2s$의 수소 투과도를 나타내었으며, 선택도는 약 10,890 이상으로 측정되었다.

Anatomical Variant of Atlas : Arcuate Foramen, Occpitalization of Atlas, and Defect of Posterior Arch of Atlas

  • Kim, Myoung Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권6호
    • /
    • pp.528-533
    • /
    • 2015
  • Objective : We sought to examine anatomic variations of the atlas and the clinical significance of these variations. Methods : We retrospectively reviewed 1029 cervical 3-dimensional (3D) CT images. Cervical 3D CT was performed between November 2011 and August 2014. Arcuate foramina were classified as partial or complete and left and/or right. Occipitalization of the atlas was classified in accordance with criteria specified by Mudaliar et al. Posterior arch defects of the atlas were classified in accordance with criteria specified by Currarino et al. Results : One hundred and eight vertebrae (108/1029, 10.5%) showed an arcuate foramen. Bilateral arcuate foramina were present in 41 of these vertebrae and the remaining 67 arcuate foramina were unilateral (right 31, left 36). Right-side arcuate foramina were partial on 18 sides and complete on 54 sides. Left-side arcuate foramina were partial on 24 sides and complete on 53 sides. One case of atlas assimilation was found. Twelve patients (12/1029, 1.17%) had a defect of the atlantal posterior arch. Nine of these patients (9/1029, 0.87%) had a type A posterior arch defect. We also identified one type B, one type D, and one type E defect. Conclusion : Preoperative diagnosis of occipitalization of the atlas and arcuate foramina using 3D CT is of paramount importance in avoiding neurovascular injury during surgery. It is important to be aware of posterior arch defects of the atlas because they may be misdiagnosed as a fracture.

Utilizing Advanced Pad Conditioning and Pad Motion in WCMP

  • Kim, Sang-Yong;Chung, Hun-Sang;Park, Min-Woo;Kim, Chang-Il;Chang, Eui-Goo
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.171-175
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process has been widely used to planarize dielectrics and metal, which can apply to employed in integrated circuits for sub-micron technology. Despite the increased use of CMP process, it is difficult to accomplish the global planarization of free-defects in inter level dielectrics and metal. Especially, defects like (micro-scratch) lead to severe circuit failure, and affects yield. Current conditioning method - bladder type, orbital pad motion- usually provides unsuitable pad profile during ex-situ conditioning near the end of pad life. Since much of the pad wear occurs by the mechanism of bladder type conditioning and its orbital motion without rotation, we need to implement new ex-situ conditioner which can prevent abnormal regional force on pad caused by bladder-type and also need to rotate the pad during conditioning. Another important study of ADPC is related to the orbital scratch of which source is assumed as diamond grit dropped from the strip during ex-situ conditioning. Scratch from diamond grit damaged wafer severely so usually scraped. Figure 1 shows the typical shape of scratch damaged from diamond. e suspected that intensive forces to the edge area of bladder type stripper accelerated the drop of Diamond grit during conditioning. so new designed Flat stripper was introduced.

  • PDF

가철성 국소의치와 후방연장 계속가공의치를 장착한 환자의 치주 및 보철 상태 (PERIODONTAL AND PROSTHETIC FINDINGS IN PATIENTS TREATED WITH REMOVABLE PARTIAL DENTURES OR DISTALLY EXTENDING CANTILEVER BRIDGES)

  • 김정찬;한수부
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.635-645
    • /
    • 1993
  • This study was perfomed to investigate the prosthodontic and periodontal status of the abutment teeth in distally extending bridges(DEBs) (78 cases) and removable partial dentures(RPDs) (43 cases) for 122 patients (55 males and 57 females) visiting department of Periodontology, Seoul National University Hospital. The average wearing periods were 67.8 months for DEBs and 66.4 months for RPDs. 38.4% of the patients in DEBs and 35.9% in RPDs complainted of chewing discomfort and 22.6% and 24.4% were not chewing on the prosthodontically - treated sides, respectively. In DEBs, when the restoration for 2nd molar supported by 1st molar & 2nd premolar was grouped to type 1, 1st molar supported by 1st & 2nd premolars was type 2, and 1st & 2nd molars supported by 1st & 2nd premolars was type 3, there was a significant differences only in the tooth mobility score among clinical parameters (type 2>type 1>type 3). In RPDs, when bilateral free-end case was grouped to type 1, and unilateral case was type 2, there was a significant difference in the Gingival index (type 1>type 2). In DEBs, 62.8% of restoration were overcontoured, 72% had interproximal space closures, 30.5% overextended pontics and 86.6% overhanging margins. In RPDs, 24.4% of the restorations were overcontoured, 45.5% had interproxinal space closures and 58.3% overhanging margins. From these results of this study, periodontal problems caused by prosthodontic defects were considered to be contributing factors in chewing discomfort.

  • PDF