• Title/Summary/Keyword: defect-correction method

Search Result 61, Processing Time 0.021 seconds

ON THE LINEARIZATION OF DEFECT-CORRECTION METHOD FOR THE STEADY NAVIER-STOKES EQUATIONS

  • Shang, Yueqiang;Kim, Do Wan;Jo, Tae-Chang
    • Journal of the Korean Mathematical Society
    • /
    • v.50 no.5
    • /
    • pp.1129-1163
    • /
    • 2013
  • Based on finite element discretization, two linearization approaches to the defect-correction method for the steady incompressible Navier-Stokes equations are discussed and investigated. By applying $m$ times of Newton and Picard iterations to solve an artificial viscosity stabilized nonlinear Navier-Stokes problem, respectively, and then correcting the solution by solving a linear problem, two linearized defect-correction algorithms are proposed and analyzed. Error estimates with respect to the mesh size $h$, the kinematic viscosity ${\nu}$, the stability factor ${\alpha}$ and the number of nonlinear iterations $m$ for the discrete solution are derived for the linearized one-step defect-correction algorithms. Efficient stopping criteria for the nonlinear iterations are derived. The influence of the linearizations on the accuracy of the approximate solutions are also investigated. Finally, numerical experiments on a problem with known analytical solution, the lid-driven cavity flow, and the flow over a backward-facing step are performed to verify the theoretical results and demonstrate the effectiveness of the proposed defect-correction algorithms.

Numerical algorithm with the concept of defect correction for incompressible fluid flow analysis (오차수정법을 도입한 비압축성 유체유동 해석을 위한 수치적 방법)

  • Gwon, O-Bung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.3
    • /
    • pp.341-349
    • /
    • 1997
  • The characteristics of defect correction method are discussed in a sample heat conduction problem showing the numerical solution of the error correction equation can predict the error of the numerical solution of the original governing equation. A way of using defect correction method combined with the existing algorithm for the incompressible fluid flow, is proposed and subsequently tested for the driven square cavity problem. The error correction equations for the continuity equation and the momentum equations are considered to estimate the errors of the numerical solutions of the original governing equations. With this new approach, better velocity and pressure fields can be obtained by correcting the original numerical solutions using the estimated errors. These calculated errors also can be used to estimate the orders of magnitude of the errors of the original numerical solutions.

ANALYSIS OF A FOURTH ORDER SCHEME AND APPLICATION OF LOCAL DEFECT CORRECTION METHOD

  • Abbas, Ali
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.3_4
    • /
    • pp.511-527
    • /
    • 2014
  • This paper provides a new application similar to the Local Defect Correction (LDC) technique to solve Poisson problem -u"(x) = f(x) with Dirichlet boundary conditions. The exact solution is supposed to have high activity in some region of the domain. LDC is combined with a fourth order compact scheme which is recently developed in Abbas (Num. Meth. Partial differential equations, 2013). Numerical tests illustrate the interest of this application.

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

RICHARDSON EXTRAPOLATION AND DEFECT CORRECTION OF MIXED FINITE ELEMENT METHODS FOR ELLIPTIC OPTIMAL CONTROL PROBLEMS

  • Chen, Yanping;Huang, Yunqing;Hou, Tianliang
    • Journal of the Korean Mathematical Society
    • /
    • v.49 no.3
    • /
    • pp.549-569
    • /
    • 2012
  • In this paper asymptotic error expansions for mixed finite element approximations to a class of second order elliptic optimal control problems are derived under rectangular meshes, and the Richardson extrapolation of two different schemes and interpolation defect correction can be applied to increase the accuracy of the approximations. As a by-product, we illustrate that all the approximations of higher accuracy can be used to form a class of a posteriori error estimators of the mixed finite element method for optimal control problems.

Surgical Correction Of Double Outlet Right Ventricle (S.D.L.) (대혈관전위를 동반한 양대혈관 우심실기시증 치험 1례 (S.D.L.))

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.225-232
    • /
    • 1979
  • A 15-year-old girl underwent successful surgical correction of double-outlet right ventricle [S.D.L.] subaortic ventricular septal defect, patent foramen ovale, and pulmonary hypoplasia with valvular stenosis. The operation consisted of an internal baffling connecting the left ventricle to the aorta through the ventricular septal defect. The pulmonary stenosis was corrected with the method of connection the right ventricle to the pulmonary artery bifurcation using the Hancock valve[18mm] contained conduit. This rare type of DORV seemed to be suitable for corrective surgery, and the patient`s condition is very good until present time (post operative 7 months).

  • PDF

Complicatons and Residual Defects After Correction of Noncomplicated Ventricular Septal Defect (단순 심실중격결손증 수술 후 합병증 및 잔존 결손)

  • Jun, Tae-Gook;Hwang, Kyung-Hwan;Lee, Ho-Seok;Huh, Jung-Hee;Park, Kay-Hyun;Park, Pyo-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.139-145
    • /
    • 2000
  • Background: The purpose of this study is to review the clinical course after the correction of noncomplicated ventricular septal defect and to analyze the morbidity and risk factors of postoperative complications and evaluate residual defect during the follow-up period. Material and Method: From September 1994 to June 1998 24 patients(median age 10 months) underwent surgery under the diagnosis of ventricular septal defect. We made a retrospective review of the clinical records including the operation notes critical care unit records echocardiography results and the follow-up records. Result: There was no early mortality nd late mortality. There was no postoperative complete conduction block. Respiratory complication was the most common complication. The body weight age type of ventricular septal defect associated anomalies and operative procedure were not related to the incidence of complications. residual ventricular septal defects aortic valve regurgitation and tricuspid valve regurgitation were insignificant in postoperative hemodynamics, Conclusions: Correction of the noncomplicated ventricular septal defect was done without mortality and complete heart block. Aggressive preoperative medical treatment and early surgical treatment may decrease postoperative complications. Postoperative residual shunt and tricuspid regurgitation were not problematic during the follow-up

  • PDF

A Clinical Analysis of Ventricular Septal Defect Infants Weighting Less Than 10kg of Body Weght (체중 10kg이하 심실중격결손증 환아의 임상적 고찰)

  • 손제문
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.650-655
    • /
    • 1994
  • The author analyzed 99patients with VSD weighting less than 10kg of body weight who underwent surgical correction from 1981 to 1992 at cardiovascular department of Hanyang University hospital. Patients occupied 29.3% of total cases who were underwent surgical corrections for congenital heart diseases during that time. Of the 99 patients, 51 patients were male [52%] and 48 patients[48%] were female. Age ranged from 28 days to 36 months with mean age of 13.6 months. Mean body weight was 7.53kg. According to Kirklin`s anatomical classification, type II defect was most common [61.6%]. Associated anomaly was found in 48 patients [48.5%]. Patent foramen ovale was most commonly associated cardiac anomaly [14.1%] and followed by atrial septal defect [12.1%], patent ductus arteriosus [10.1%]. Cardiac catheterization data were analyzed. The most common range of Qp/Qs, Rp/Rs, Pp/Ps were above 3.0, 0.1 - 0.25, and above 0.75 respectively. Among the indications of surgical correction, there were pulmonary hypertention in 69 patients, congestive heart failure in 44 patients, frequent respiratory infection in 47 patients, growth retardation in 33 patients. The most common surgical approach and method for VSD closure were right atriotomy[48.3%] and dacron patch closure[93.3%]. Complication rate was 13.1% [13 cases], and overall mortality was 17.1% [17 cases]. The cause of death consisted of low cardiac output syndrome[11 cases], acute renal failure[3 cases], sepsis[2 cases] and pulmonary insufficiency[1 case] in order of frequency.

  • PDF

Reconstruction of Lower Eyelid Defect using Neighboring Remnant Skin (인접 잉여 피부를 이용한 아랫 눈꺼풀 결손의 재건)

  • Hong, Chang-Yil;Kim, Sun-Goo;Kim, Yu-Jin;Lee, Se-Il
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.492-495
    • /
    • 2010
  • Purpose: Facial tumor excision is a common cause of lower eyelid defect in old patients. Many methods have been introduced for the reconstruction of lower eyelid. However, conventional surgical method can cause various complications like scar, ectropion and unnatural color matching. Thus, we introduce a simple and aesthetically acceptable method for the reconstruction of lower eyelid defect. Methods: Three elderly patients with skin cancer in the unilateral lower eyelid were operated by the new method. Following a wide excision of skin cancer, subcilliary incision of lower blepharoplasty was carried out. Elevated skin flap of lower eyelid was redrapped for the correction of defect and the remnant skin from lateral portion of lower eyelid was used for full thickness skin graft (FTSG) to correct the remaining defect. Results: All grafts survived and color match of the graft was excellent without ectropion. Furthermore, wrinkles of the lower eyelid were improved after the blepharoplasty. Conclusion: Lower eyelid defect resulting from wide excision of malignant tumor in old patients could be reconstructed successfully by modifying the conventional lower eyelid blepharoplasty along with FTSG using the remnant skin.