• Title/Summary/Keyword: decreases of dust loading

Search Result 5, Processing Time 0.021 seconds

Case Studies of Mass Concentration Variation in the Central-Southern Korean Peninsula Caused by Synoptic Scale Transport of Dust Storms

  • Kim, Hak-Sung;Cho, Jae-Hee
    • Journal of the Korean earth science society
    • /
    • v.40 no.4
    • /
    • pp.414-427
    • /
    • 2019
  • In East Asia, the long-range transport of dust storms originating from Mongolia and northern China affects airborne dust loadings over downwind areas in the southern Korean Peninsula. Since 1997, dust loading cases caused by dust storms have been observed using the thresholds of total suspended particles (TSP, ${\geq}250{\mu}g\;m^{-3}\;hr^{-1}$) and particulate matter less than $10{\mu}g$ ($PM_{10}$, ${\geq}190{\mu}g\;m^{-3}\;hr^{-1}$) in the central-southern Korean Peninsula. There were two dust loading cases that exceeded these thresholds in 2016 and three in 2017, which reflects the downward trend of the last twenty-one years in the central-southern Korean Peninsula. Furthermore, five other dust loading cases with mass concentrations lower than the thresholds were observed from 2016 to 2017. In the moderate dust loading cases exceeding the thresholds, a descending motion of cut-off lows below $45^{\circ}N$ and a southward trough at 500 hPa gpm isopleths intensified at the western ridge, and largely extended the surface high-pressure system over southeast China. Airborne dust loadings following pronounced north-westerlies in the forward side of the high-pressure system were transported to the surface of the central-southern Korean Peninsula. However, in slight dust loading cases lower than the thresholds, the restricted descending motion of cut-off lows over $45^{\circ}N$ and the southwestward trough at 500 hPa gpm isopleths intensified the zonal flow over the Korean Peninsula. Surface high- and low-pressure systems moved eastward from the source compared to moderate dust loading cases. Due to the zonal movement of dust storms traversing eastern China, slight dust loading cases were observed with relatively higher ratios of $PM_{2.5}/TSP$ and carbon monoxide (CO) in the central-southern Korean Peninsula.

Study on the assessment methodology for the PM10 generated from tire-dust considering the axle load of the truck according to the loading method (화물차 적재 방식에 따른 축 하중을 고려한 타이어 먼지 중 PM10 발생량 평가기법 연구)

  • Lee, Eunjeong;Lee, Heekwan
    • Journal of Urban Science
    • /
    • v.11 no.2
    • /
    • pp.45-54
    • /
    • 2022
  • Recently, regulations on automobile exhaust gas emission are being strengthened. Accordingly, automobile exhaust gas emissions are expected to decrease and continue to decrease. On the other hand, many countries do not yet consider the emission of non-exhaust air pollutants from automobiles as important. Automobile non-exhaust substances are classified into three categories: tire dust emissions, brake wear emissions, and road scattering dust. In particular, in the case of tire dust, research results exist that pollutant emissions increase as the weight of a vehicle increases. Since the weight of trucks varies according to the load and the load along the axles is also different, it can be expected that the emission of PM10 from the tire dust will be different depending on the loading method. Therefore, this study was conducted on the amount of PM10 generated in tire dust considering the axle load of the truck according to the loading method. However, it was confirmed that the total amount of PM10 was less than that all loads are loaded in the front or rear when the load was evenly distributed in the front and rear of the cargo compartment. In particular, if the load is distributed evenly in the front and back of the cargo compartment and the load in the front part is divided into 2 to 6 and loaded, as the number of divided loading increases the amount of PM10 generated decreases. And when the load is divided into 6 pieces, the total amount of PM10 generated is 0.3952g, the minimum value. If the load is divided into 6 or more and loaded evenly, the total PM10 generated continuously increases and converges to about 0.3964g.

Development and Basic Performance Characterization of Neutralized Fabric Filter (제전사여과포의 개발 및 기초성능 규명)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 1998
  • A neutralized fabric filter of which major raw materials were polyester and stainless steel fibers was developed and its physiochemical properties and basic filter characteristics were investigated. Four finds of dusts generated in the typical domestic industry were used, which were coke dust from a steel manufacturing process, cement dust from a cement manufacturing process, flu ash from a fluidized-bed combustor, and incinerator ash from a waste plastics incinerator. The physicochemical properties of the neutralized fabric filter were analyzed in terms of changes in tensile strength and initial elastic modulus under $SO_2$ and $NO_2$ atmospheres, mean flow pore pressure, bubble point pore diameter, mean flow pore diameter, and pore size distribution. In addition, the pressure drop, dust penetration, and figure of merit for the fabric filter were investigated in a bench-scale filter testing unit. The pressure drop increased as the filtration velocity and dust loading increased, and its increasing shape depended on the type of dust. The dust penetration rapidly decreased as the dust loading increased irrespective of the type of dust. The figures of merit for the fabric filters increased in the early stage of filtration and then showed rapid decreases followed maintaining a constant level.

  • PDF

Assessment of the Nitrate Radical Chemistry and Chemical Composition on Jeju Island during the Asian Pollution Period in the Spring of 2001

  • Shon, Zang-Ho;Kim, Ki-Hyun;Keith N. Bower;Lee, Gangwoong;Kim, Jiyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E3
    • /
    • pp.137-148
    • /
    • 2003
  • In this study, we examined the influence of long-range transport of dust particles and air pollutants on the photochemistry of NO$_3$on Jeju Island, Korea (33.17 N, 126.10$^{\circ}$E) during the Asian Dust-Storm (ADS) period of April 2001. Three ADS events were observed during the periods of 10∼12, 13∼14, and 25∼26 April. Average concentration level of nighttime NO$_3$on Jeju Island during the ADS period was estimated to be about 2 x 10$^{8}$ molecules cm$^{-3}$ ( - 9 pptv). Decreases in NO$_3$levels during the ADS period was likely to be determined mainly by the enhancement of the $N_2$O$_{5}$ heterogeneous reaction on dust aerosol surfaces. The reaction of N20s on aerosol surfaces was a more important sink for nighttime N03 during the ADS due to the significant loading of dust particles. The reaction of $N_2$O$_{5}$ with NMHCs and the gas-phase reaction of N20s with water vapor were both significant loss mechanisms during the study period, especially during the NADS. However, dry deposition of these oxidized nitrogen species and a heterogeneous reaction of NO$_3$were of no importance. Short-term observations of $O_3$, NO$_2$, DMS, and SO$_2$in the MBL indicated that concentrations of most of these chemical species were different between the ADS and non - Asian - Dust-Storm (NADS) periods, implying that their levels were affected sensitively by the differences in air mass trajectories.

An Experimental Study of the Air-side Particulate Fouling of Finned-Tube Heat Exchangers of Air Conditioners by using Accelerated Particle-Loading System (파울링 형성 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 실험적 연구)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱;옥주호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.802-808
    • /
    • 2003
  • The air-side particulate fouling of the HVAC heat exchangers degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. The purpose of this study is to investigate the fouling characteristics using accelerated particle loading system. The fouling characteristics are analyzed as functions of a dust concentration, a face velocity and a wet or dry surface condition. The pressure drop increases with increasing test operation and reaches constant asymptotic level. For the saturated condition due to particle loading, the pressure drop across the slitted finned-tube heat exchangers at the face velocity of 1 m/sec increases up to 57% and the cooling capacity decreases about 2%. The cooling capacities are not affected greatly by the presence of the fouling deposits if the thickness of the fouling deposits can not change substantially the flow pattern through the fins.