• 제목/요약/키워드: decay estimate

검색결과 125건 처리시간 0.024초

물질의 진동감쇠 시험법 비교 (Test method comparison for vibration-damping of materials)

  • 신수현;이용봉;정성수;조승일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.700-703
    • /
    • 2003
  • The test method of ASTM E 756 and KS D 0076 to estimate vibration-damping properties is compared. Comparison method depending on specimen support, exciting method and calculation method for loss factor is used. Half-power bandwidth method and vibration decay method is used in the calculation method for loss factor, and Young's modulus is decided by geometric character and density for specimen and resonance frequency. Vibration measurement sensor is compared by using non-contact displacement detector, velocity detector and accelerometer. This paper is also presented the matter which is able to cause error in the measurement

  • PDF

외국자본유입이 우리나라 은행산업의 효율성에 미치는 영향 (Effects of Foreign Capital Inflow on Efficiency of Bank Industry)

  • 김창범
    • 통상정보연구
    • /
    • 제9권3호
    • /
    • pp.23-32
    • /
    • 2007
  • The purpose of this study is to estimate and analyse the relationship between efficiency of bank industry and macroeconomic variables. We employ Johansen's multivariate cointegration methodology, since the model must be stationary to avoid the spurious results. The empirical results show that our model is stationary as well as mean-reverting. This paper also applies impulse-response functions to get additional information regarding the responses of the bank spread to the shocks economic variables such as long and short term interest rates differential, banking organ liquidity, business cycle index, and foreigner's net equity investment. The results indicate that while the bank spread respond positively to liquidity and equity investment shocks and then decay very quickly.

  • PDF

Steel beam의 진동감쇠 특성평가 (Estimation of Vibration-damping Properties for Steel Beam)

  • 신수현;남효덕;정성수;이용봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.439-442
    • /
    • 2003
  • The test method of ASTM E 756 and JIS G 0602 to estimate vibration-damping properties is presented. Measurement method depending on specimen support, exciting method and calculation method for loss factor is used. Half-power bandwidth method and vibration decay method is used in the calculation method for loss factor, and Young's modulus is decided by geometric character and density for specimen and resonance frequency. Vibration measurement sensor is compared by using non-contact displacement detector, velocity detector and accelerometer. The cause of measurement error is also presented.

  • PDF

NFR 슬라이더의 동특성 분석 (Dynamic Analysis of NFR Slider)

  • 안채헌;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.586-591
    • /
    • 2001
  • Dynamic analysis using impulse responses is formulated to estimate effect of slider rail shape on dynamic responses. Impulse responses are obtained on numerical nonlinear model including rigid motion of slider and fluid motion of air bearing under the slider. Dynamic characteristics of slider motion are evaluated by utilizing the decay ratio of impulse responses and modal frequencies from frequency response functions. The dynamic characteristics of the developed NFR(Near Field Recording) slider are checked by comparing those of HDD sider(Nutcracker). Also, sensitivities of slider position conditions and rotation speed on the dynamic characteristics are investigated. The researches show that the utilized method is a good indicator of designing the better slider.

  • PDF

ESSENTIAL NORMS OF INTEGRAL OPERATORS

  • Mengestie, Tesfa
    • 대한수학회지
    • /
    • 제56권2호
    • /
    • pp.523-537
    • /
    • 2019
  • We estimate the essential norms of Volterra-type integral operators $V_g$ and $I_g$, and multiplication operators $M_g$ with holomorphic symbols g on a large class of generalized Fock spaces on the complex plane ${\mathbb{C}}$. The weights defining these spaces are radial and subjected to a mild smoothness conditions. In addition, we assume that the weights decay faster than the classical Gaussian weight. Our main result estimates the essential norms of $V_g$ in terms of an asymptotic upper bound of a quantity involving the inducing symbol g and the weight function, while the essential norms of $M_g$ and $I_g$ are shown to be comparable to their operator norms. As a means to prove our main results, we first characterized the compact composition operators acting on the spaces which is interest of its own.

30CMM급 태양기공 전기집진 설비의 실내분진 정화 능력에 관한 실험연구 (An Experimental Study of 30CMM Solar Transpired Collector and Cyclone(STCC) System on Indoor Air Dust Removal Performance)

  • 노지희;박상현;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.37-45
    • /
    • 2005
  • Higher requirement of advanced building design code and the development of construction technique have resulted in more thermal and air tight buildings. This has caused the sick building syndrome in a indoor air quality has been relatively getting worse. A new concept with a solar fresh air heating and electrostatic precipitator or called as STCC(Solar Transpired Collector and Cyclone) has been proposed to solve this IAQ issue. This paper describes the assessment study of STCC system under different outdoor airflow rates. The experiment was carried out under real condition with 30CMM STCC system test facility. Incense smoke was used to study the particle concentration decay trends under outdoor airflow rates 0CMM, 10CMM, 20CMM, 30CMM, with applied voltages of 5kV and 15kV for collecting and discharging electrodes of an Electrostatic Precipitator. Result shows that the particle decay increases by increasing the outdoor airflow rates. The collection efficiency, dust cleaning effectiveness(P) and application area calculation result comparisons have also been studied. This factors could be used to estimate how a dust of indoor air quality(IAQ) and removed for a building space with a STCC system.

연속회분식 반응 공정에서 동역학적 계수 및 미생물합성에 사용된 영양물질 산정 (Estimation of Kinetic Coefficient and Assimilated Nutrients Mass in SBR Process)

  • 지대현;신상우;이광호;이재근
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.607-612
    • /
    • 2007
  • In this study, we investigated the variations of the kinetic coefficients and Chemical Oxygen Demand (COD), N and P mass used for assimilation of a sequencing batch reactor (SBR) system with the variation of SRTs; SRTs of 7.5, 10.0, 12.5, 15.0 and 20.0 days were tested in one cycle of SBR operation to determine the optimum conditions for the operation of the SBR and estimate its COD, nitrogen and phosphorus removal efficiencies. The SBR system was operated under the conditions as follows: an operation time of 6 hours per cycle, a hydraulic retention time (HRT) of 12 hours, an influent COD loading of $0.4kg/m^3/day$, and an influent nitrogen loading of $0.068kgT-N/m^3/day$. The yield coefficient (Y) and decay rate coefficient ($k_d$) were estimated to be 0.4198 kgMLVSS/kgCOD and $0.0107day^{-1}$ by calculating the removal rate of substrate according to the variation of SRT. Considering total nitrogen amount removed by sludge waste process, eliminated by denitrification, and in clarified water effluent with reference to 150 mg/cycle of influent nitrogen amount, the percentage of nitrogen mass balance from the ratio of the nitrogen amount in effluent (N output) to that in influent (N input) for Runs 1~5 were 95.5, 97.0, 95.5, 99.5, and 95.5%, respectively, which is well accounted for, with mass balances close to 100%.

ROLE OF PASSIVE SAFETY FEATURES IN PREVENTION AND MITIGATION OF SEVERE PLANT CONDITIONS IN INDIAN ADVANCED HEAVY WATER REACTOR

  • Jain, Vikas;Nayak, A.K.;Dhiman, M.;Kulkarni, P.P.;Vijayan, P.K.;Vaze, K.K.
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.625-636
    • /
    • 2013
  • Pressing demands of economic competitiveness, the need for large-scale deployment, minimizing the need of human intervention, and experience from the past events and incidents at operating reactors have guided the evolution and innovations in reactor technologies. Indian innovative reactor 'AHWR' is a pressure-tube type natural circulation based boiling water reactor that is designed to meet such requirements, which essentially reflect the needs of next generation reactors. The reactor employs various passive features to prevent and mitigate accidental conditions, like a slightly negative void reactivity coefficient, passive poison injection to scram the reactor in event of failure of the wired shutdown systems, a large elevated pool of water as a heat sink inside the containment, passive decay heat removal based on natural circulation and passive valves, passive ECC injection, etc. It is designed to meet the fundamental safety requirements of safe shutdown, safe decay heat removal and confinement of activity with no impact in public domain, and hence, no need for emergency planning under all conceivable scenarios. This paper examines the role of the various passive safety systems in prevention and mitigation of severe plant conditions that may arise in event of multiple failures. For the purpose of demonstration of the effectiveness of its passive features, postulated scenarios on the lines of three major severe accidents in the history of nuclear power reactors are considered, namely; the Three Mile Island (TMI), Chernobyl and Fukushima accidents. Severe plant conditions along the lines of these scenarios are postulated to the extent conceivable in the reactor under consideration and analyzed using best estimate system thermal-hydraulics code RELAP5/Mod3.2. It is found that the various passive systems incorporated enable the reactor to tolerate the postulated accident conditions without causing severe plant conditions and core degradation.

지하철 접근성 증가의 공간적 파급효과 산출모형 개발 (Model Development for the Spatial Diffusion Effect Estimation of Nodal Accessibility Increment in the Subway Network)

  • 이금숙
    • 한국경제지리학회지
    • /
    • 제1권1호
    • /
    • pp.137-149
    • /
    • 1998
  • 교통망의 확충계획이 있거나 확충작업이 이루어지고 있는 지역에서는 그로 인한 직접적인 접근성 증가와 더불어 교통망의 개선에 따른 접근성 증가의 주변지역으로의 파급효과를 정확히 신출할 수 있다면 지역 전체의 접근성 공간구조를 파악할 수 있게 되고, 지가와 토지이용의 변화를 정확히 예측할 수 있게 되어 교통을 포함한 각종 지역계획과정에서 효율적이고 합리적인 대안선정을 위한 기준을 제공할 수 있을 것이다. 기존의 그래프이론에 기반을 둔 접근성 측정모형에 의해 산출되는 결정점의 접근성 증가가 주변지역으로 파급되는 효과를 정확히 산출할 수 있는 이론적 모형의 개발을 시도하였다. 특히 결정점을 중심으로 주변지역으로 거리가 멀어지면서 변화하는 지하철 접근도의 영향력을 측정하기 위한 이론적 모형을 제시하고 있다. 지하철역의 접근도가 주변지역으로 확산되는 정도는 주변지역에서 그 지하철역을 이용하는 정도와 일치한다고 보고 주변지역의 지하철역 이용밀도를 기반으로 수학적 함수식을 도출하였다. 이러한 연구는 궁극적으로는 최근 지리적 분석기법으로 각광을 받고 있는 GIS기법에 접목시켜 지표현상의 설명에 핵심이 되는 접근성의 공간적 보간에 대한 이론적 근거를 마련한다는 의미를 지닌다.

  • PDF

Determining chlorine injection intensity in water distribution networks: a comparison of backtracking and water age approaches

  • Flavia D. Frederick;Malvin S. Marlim;Doosun Kang
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.170-170
    • /
    • 2023
  • Providing safe and readily available water is vital to maintain public health. One of the most prevalent methods to prevent the spread of waterborne diseases is applying chlorine injection to the treated water before distribution. During the water transmission and distribution, the chlorine will experience a reduction, which can imply potential risks for human health if it falls below the minimum threshold. The ability to determine the appropriate initial intensity of chlorine at the source would be significant to prevent such problems. This study proposes two methods that integrate hydraulic and water quality modeling to determine the suitable intensity of chlorine to be injected into the source water to maintain the minimum chlorine concentration (e.g., 0.2 mg/l) at each demand node. The water quality modeling employs the first-order decay to estimate the rate of chlorine reduction in the water. The first method utilizes a backtracking algorithm to trace the path of water from the demand node to the source during each time step, which helps to accurately determine the travel time through each pipe and node and facilitate the computation of time-dependent chlorine decay in the water delivery process. However, as a backtracking algorithm is computationally intensive, this study also explores an alternative approach using a water age. This approach estimates the elapsed time of water delivery from the source to the demand node and calculate the time-dependent reduction of chlorine in the water. Finally, this study compares the outcomes of two approaches and determines the suitable and effective method for calculating the chlorine intensity at the source to maintain the minimum chlorine level at demand nodes.

  • PDF