• Title/Summary/Keyword: decay detection

Search Result 64, Processing Time 0.032 seconds

Regulation of Contraction and $Ca^{2+}$ Transient by Histidine-rich $Ca^{2+}$-binding Protein in Ventricular Myocytes (히스티딘-리치 $Ca^{2+}$ 결합 단백질에 의한 심실근세포 수축 및 $Ca^{2+}$ Transient의 조절)

  • Son, Min-Jeong;Kim, Joon-Chul;Kim, Seong-Woo;Ahn, Jong-Real;Woo, Sun-Hee
    • YAKHAK HOEJI
    • /
    • v.56 no.6
    • /
    • pp.377-381
    • /
    • 2012
  • The histidine-rich $Ca^{2+}$ binding protein (HRC) is a $Ca^{2+}$ binding protein in the sarcoplasmic reticulum (SR). In this study, we examined whether the HRC is involved in the regulation of cardiac contraction and $Ca^{2+}$ signaling using HRC knock-out (KO) mouse ventricular myocytes. In field-stimulated single mouse ventricular myocytes, cell shortenings and $Ca^{2+}$ transients were measured using a video edge detection and a confocal $Ca^{2+}$ imaging, respectively. Compared with the wide-type (WT) myocytes, the magnitudes of cell shortenings were significantly larger in HRC KO cells (P<0.01, WT vs. KO). The rate of contraction and relaxation was significantly accelerated in HRC KO myocytes (P<0.05 and P<0.01, respectively, WT vs. KO). The magnitudes of $Ca^{2+}$ transients were increased by HRC KO (P<0.01, WT vs. KO). In addition, the decay of the $Ca^{2+}$ transient was faster in HRC KO cells than in wild-type cells P<0.01, WT vs. KO). These results suggest that HRC may suppress SR $Ca^{2+}$ releases and decay of $Ca^{2+}$ transients during action potentials, thereby attenuating ventricular contraction and relaxation.

Characterization of the Surface Contribution to Fluorescence Correlation Spectroscopy Measurements

  • Chowdhury, Salina A.;Lim, Man-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.583-589
    • /
    • 2011
  • Fluorescence correlation spectroscopy (FCS) is a sophisticated and an accurate analytical technique used to study the diffusion of molecules in a solution at the single-molecule level. FCS is strongly affected by many factors such as the stability of the excitation power, photochemical processes, mismatch between the refractive indices, and variations in the cover glass thickness. We have studied FCS near the surface of a cover glass by using rhodamine 123 as a fluorescent probe and have observed that the surface has a strong influence on the measurements. The temporal autocorrelation of FCS decays with two characteristic times when the confocal detection volume is positioned near the surface of the cover glass. As the position of the detection volume is moved away from the surface, the FCS autocorrelation becomes one-component decaying; the characteristic time of the decay is the same as the faster-decaying component in the FCS autocorrelation near the surface. This observation suggests that the faster component can be attributed to the free diffusion of the probe molecules in the solution, while the slow component has its origin from the interaction between the probe molecules and the surface. We have characterized the surface contribution to the FCS measurements near the surface by changing the position of the detection volume relative to the surface. The influence of the surface on the diffusion of the probe molecules was monitored by changing the chemical properties of the surface. The surface contribution to the temporal autocorrelation of the FCS strongly depends on the chemical nature of the surface. The hydrophobicity of the surface is a major factor determining the surface influence on the free diffusion of the probe molecules near the surface.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Real-time 14N NQR-based sodium nitrite analysis in a noisy field

  • Mohammad Saleh Sharifi;Ho Seung Song;Hossein Afarideh;Mitra Ghergherehchi;Mehdi Simiari
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4570-4575
    • /
    • 2023
  • Noise and Radio-frequency interference or RFI causes a significant restriction on the Free induction Decay or FID signal detection of the Nuclear Quadrupole Resonance procedure. Therefore, using this method in non-isolated environments such as industry and ports requires extraordinary measures. For this purpose, noise reduction algorithms and increasing signal-to-noise-and-interference ratio or SNIR have been used. In this research, sodium nitrite has been used as a sample and algorithms have been tested in a non-isolated environment. The resonant frequencies for the 150 g of test sample were measured at 303 K at about 1 MHz and 3.4 MHz. The main novelty in this study was, (1) using two types of antennas in the receiver to improve adaptive noise and interference cancellation, (2) using a separate helical antenna in the transmitter to eliminate the duplexer, (3) estimating the noise before sending the pulse to calculate the weighting factors and reduce the noise by adaptive noise cancellation, (3) reject the interference by blanking algorithm, (4) pulse integration in the frequency domain to increase the SNR, and (5) increasing the detection speed by new pulse integration technique. By interference rejection and noise cancellation, the SNIR is improved to 9.24 dB at 1 MHz and to 7.28 dB at 3.4 MHz, and by pulse integration 44.8 dB FID signal amplification is achieved, and the FID signals are detected at 1.057 MHz and 3.402 MHz at room temperature.

Soot Primary Particle Size Measurement in a Ethylene Diffusion Flame Using Time-Resolved Laser-Induced Incandescence (2차원 시분해 레이저 유도 백열법을 이용한 에틸렌 확산 화염에서의 매연 입자 크기 측정)

  • Shon, Moo-Kang;Moon, Gun-Feel;Kim, Gyu-Bo;Lee, Jong-Ho;Jeong, Dong-Soo;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1140-1145
    • /
    • 2004
  • Laser-induced incandescence (LII) is introduced as a valuable tool for the characterization of nanoparticles in flame environments. This technique is based on the heating of the particles by a short laser pulse and the subsequent detection of the thermal radiation. It has been applied successfully for the investigation of soot in different fields of application. The evaluation of the temporal decay of the laser-induced incandescence (LII) signal from soot particles is introduced as a technique to obtain two-dimensional distributions of particle sizes and is applied to a laminar diffusion flame. This novel approach to soot sizing exhibits several theoretical and technical advantages compared with the established combination of elastic scattering and LII, especially as it yields absolute sizes of primary particles without requiring calibration. With this technique a spatially resolved 2-D measurement of soot primary particle sizes is feasible in a combination process form the ratio of emission signals obtained at two delay times after a laser pulse, as the cooling behavior is characteristic of particle size.

  • PDF

A Case of Acute Hydrogen Sulfide Intoxication Caused Rapid Loss of Consciousness (급속한 의식 변화를 초래한 급성 황화수소 중독 1례)

  • Ahn, Jung-Hwan;Jung, Yoon-Seok
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.2 no.2
    • /
    • pp.147-150
    • /
    • 2004
  • Hydrogen sulfide is a colorless, and malodorous 'rotten eggs' gas that results from the decay of organic material. It is a byproduct of industry and agriculture. The mechanism of its toxicity is primarily related to inhibition of oxidative phosphorylation, which causes a decrease in available cellular energy. Because there is no rapid method of detection that is of clinical diagnostic use, management decisions must be made based on history, clinical presentation, and diagnostic tests that imply hydrogen sulfide's presence. Although there is some anecdotal evidence to suggest that the early use of hyperbaric oxygen is beneficial, supportive care remains the mainstay of therapy. We describe an occupational exposure to hydrogen sulfide gas in 51-year-old man. While cleaning the sewage of pigs. he became unconscious. When he arrived in the emergency department, he had irritability and confused mentality. The typical smell of rotten eggs on clothing and exhaled air were enough to be considered to be exposed to hydrogen sulfide. Hyperbaric oxygen therapy was performed. He had a recovery to normal function.

  • PDF

DETECTION AND CLASSIFICATION OF DEFECTS ON APPLE USING MACHINE VISION

  • Suh, Sang-Ryong;Sung, Je-Hoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.852-862
    • /
    • 1996
  • This study was carried out to develop tools to detect defects of apple using machine vision. For the purpose, 6 kinds of frame for color images, R, G, B, h, S, and I frame, and a frame for near infra-red images (NIR frame) were tested first to select one which is useful to segment defect areas from apple images. After then, several methods to classify kind of defect for the segmented defect areas were developed and tested. Five kinds of apple defect -bruise , decay ,fleck worm hole and scar were investigated . The results are as follows: NIR frame was selected as the best one among the 7 kinds of image frame, and R, G and I frames showed favourable result to segment areas of apple defect. Various features of the segmented defect areas were measured to classify the defect areas. Eight kids of feature of the areas-size, roundness, axes length ratio, mean and variance of pixel values, variance of real part of spectrum, mean and variance of power spectrum resulted from spacial ourier transform were observed for the segmented defect areas in the selected 4 frames. then procedures to classify defects using the features were developed for the 4 frames and tested with 75-113 defects on apples. The test resulted that NIR and I frames showed high accuracies to classify the kind of defect as 77% and 76% , respectively.

  • PDF

Crystal growth and scintillation properties of CsI:Na (CsI:Na 결정 육성과 섬광 특성)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, H.J.
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.443-448
    • /
    • 2010
  • In this work, the scintillation properties of CsI:Na crystal were investigated as radiation detection sensor. This scintillation material was grown by a 2-zone vertical Bridgman method. Under X-ray excitation the crystal shows a broad emission band between 280 nm and 690 nm wavelength range, peaking at 413 nm. Energy resolution for $^{137}Cs$ 662 keV $\gamma$-rays of the crystal was measured to be 6.9 %(FWHM). At room temperature, the crystal exhibits three exponential decay time components. The fast and major component of scintillation time profile of the crystal emission decays with a 457 ns time constant. Absolute light yield of the crystal was estimated to be 53,000 ph/MeV using LAAPD. The sample crystal shows proportionality of 30 % in the measured energy range from 31 to 1,333 keV. And the $\alpha/\beta$ ratio of the crystal was 0.14.

A preliminary study on real-time Rn/Tn discriminative detection using air-flow delay in two ion chambers in series

  • Sopan Das ;Junhyeok Kim ;Jaehyun Park ;Hojong Chang;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4644-4651
    • /
    • 2022
  • Due to its short half-life, thoron gas has been assumed to have negligible health hazards on humans compared to radon. But, one of the decay products with a long half-life can make it to be transported to a long distance and to cause a severe internal dose through respiration. Since most commercial radon detectors can not discriminate thoron signals from radon signals, it is very common to overestimate radon doses which in turn result in biased estimation of lung cancer risk in epidemiological studies. Though some methods had been suggested to measure thoron and radon separately, they could not be used for real-time measurement because of CR-39 or LR-115. In this study, an effective method was suggested to measure radon and thoron separately from the free air. It was observed that the activity of thoron decreases exponentially due to delay time caused by a long pipe between two chambers. Therefore from two ion chambers apart in time, it was demonstrated that thoron and radon could be measured separately and simultaneously. We also developed a collimated alpha source and with this source and an SBD, we could convert the ion chamber reading to count rate in cps.

Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring (막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.248-254
    • /
    • 2017
  • In order to secure the reliability of pathogenic microorganisms such as Cryptosporidium and Giaridia, which are chlorophilic protozoans, membrane filtration systems have been widely used in water purification process. hese integrity tests are classified into direct and indirect methods. Based on the bubble point theory, the pressure-based test in the direct method is presented in the USEPA Guidance Manual with sensitivity to detect a minimum size of pathogenic microorganisms of $3{\mu}m$ or more. Indirect methods are widely used in that they are capable of continuous operation in on-line state, but there is a very low sensitivity of damage detection compared to the direct method, and there is a limit that can not specify the damage area, so it is necessary to improve this sensitivity. In this study, we compared the LRVDIT and UCL values according to the type of membrane defect, number of fiber breaks, and initial set pressure value through the Integrity Test by Pressure Decay Test (PDT).