• 제목/요약/키워드: dc parameter

검색결과 426건 처리시간 0.038초

TiO2 박막의 증착거동에 미치는 스퍼터링 공정변수의 영향 (Effect of Sputtering Parameter on the Deposition Behavior of TiO2 Thin Film)

  • 김을수;이건환;권식철;안효준
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.8-16
    • /
    • 2003
  • $TiO_2$ thin films were deposited by DC reactive magnetron sputtering with variations in sputtering parameter such as Ar and $O_2$ flow rate, DC power, substrate temperature and magnetic field. Deposition rate, crystal structure, chemical bond of $TiO_2$ films on the deposition conditions were investigated by Alpha-step, X-ray Diffractometer(XRD), X-ray Photoelectron Spectroscopy(XPS). When the DC power was applied at 500watt, deposition rate of $TiO_2$ film was about 480A/min. $TiO_2$ films coated under the deposition condition of 15sccm Ar and 7~10sccm $O_2$ flow rate was only observed anatase phase. With increasing substrate temperature from RT to $300^{\circ}C$, crystal orientation of $TiO_2$ films variously became.

PC기반 병렬 분산제어방식을 이용한 곡면유리 자동성형기 개발 (Development of Bent Glass Automatic Shaping System using PC-based Parallel Distributed Control Scheme)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.40-45
    • /
    • 2004
  • 본 논문에서는 병렬 분산제어 방식을 이용한 곡면유리 자동성형 시스템을 개발한다. 설계된 시스템은 PC, 하나의 주제어기, 그리고 11개의 서보제어기로 구성된다. 각 요소들은 RS-232C와 8비트 데이터 버스로 연결된다. 안정성과 제어성능을 고려하여 정밀 PID 모션제어기 프로세서와 DC모터 제어에 사용되는 H-브리지를 사용한다. 설계된 시스템에서, PC는 주어진 곡률반경에 대한 각 구조물의 위치 값을 계산하고 이 값에 대응하는 모터 회전 데이터를 계산하며 작업자의 조작 입력을 위한 사용자 인터페이스를 제공한다. 주제어기는 PC로부터 동작 명령과 제어 파라미터를 받아 버스 통신방식을 이용하여 이를 각 서보제어기로 전달하며 서보제어기는 주제어기로부터 넘겨받은 동작명령과 제어 파라미터를 이용하여 각 모터에 대하여 PID제어를 수행한다.

  • PDF

직류+60[Hz] 교류 중첩전압에 대한 ZnO 피뢰기 소자의 전기적 특성 (Electrical Characteristics of ZnO Surge Arrester Elements Subjected to the Mixed DC and 60[Hz] AC Voltages)

  • 이복희;양순만
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.41-47
    • /
    • 2012
  • This paper deals with the electrical characteristics related to power loss, equivalent resistance, and leakage currents flowing through new and deteriorated zinc oxide(ZnO) arrester elements subjected to the mixed DC and 60[Hz] AC voltages. The test specimens were deteriorated by 8/20[${\mu}s$] impulse current of 2.5[kA]. The leakage current-applied voltage($I-V$) characteristic curves of ZnO surge arrester elements were measured as a parameter of the ratio of the peak of 60[Hz] AC voltage to the peak of total voltage. As a consequence of test results, in case of the same applied voltage, the leakage currents flowing through the deteriorated ZnO arrester elements were higher than those flowing through the new ZnO surge arrester elements. The cross-over phenomenon in $I-V$ curves of ZnO surge arrester elements measured as a parameter of the mixed ratio of DC and AC voltages was observed at the low current domain. The effect of DC voltage on the leakage current flowing through ZnO surge arrester elements is pronounced at the same magnitude of test voltages. In addition, the larger the applied number of 8/20[${\mu}s$] impulse current of 2.5[kA] is, the greater the power loss is, in particular, the more severe the power loss increases at higher applied voltages.

Design of DC Side Voltage and Compensation Analysis of THD for Shunt Power Quality Controller under System Load of Rectifier with R-L Load

  • Zhao, Guopeng;Han, Minxiao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.30-40
    • /
    • 2015
  • For a shunt power quality controller (SPQC) the DC side voltage value which is closely related to the compensation performance is a significant parameter. Buy so far, very little discussion has been conducted on this in a quantitative manner by previous publications. In this paper, a method to design the DC side voltage of SPQC is presented according to the compensation performance in the single-phase system and the three-phase system respectively. First, for the reactive current and the harmonic current compensation, a required minimal value of the DC side voltage with a zero total harmonic distortion (THD) of the source current and a unit power factor is obtained for a typical load, through the equivalent circuit analysis and the Fourier Transform analytical expressions. Second, when the DC side voltage of SPQC is lower than the above-obtained minimal value, the quantitative relationship between the DC side voltage and the THD after compensation is also elaborated using the curve diagram. Hardware experimental results verify the design method.

대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선 (Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors)

  • 이태봉
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.213-218
    • /
    • 2017
  • The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully.

Inverse Problem Methodology for Parameter Identification of a Separately Excited DC Motor

  • Hadef, Mounir;Mekideche, Mohamed Rachid
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.365-369
    • /
    • 2009
  • Identification is considered to be among the main applications of inverse theory and its objective for a given physical system is to use data which is easily observable, to infer some of the geometric parameters which are not directly observable. In this paper, a parameter identification method using inverse problem methodology is proposed. The minimisation of the objective function with respect to the desired vector of design parameters is the most important procedure in solving the inverse problem. The conjugate gradient method is used to determine the unknown parameters, and Tikhonov's regularization method is then used to replace the original ill-posed problem with a well-posed problem. The simulation and experimental results are presented and compared.

영구자석 직류전동기의 회전자 치(齒) Parameter에 따른 특성해석 (Characteristic Analysis on Teeth Parameter of Permanent Magnet DC Motor)

  • 김철호;배상한;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.133-135
    • /
    • 1996
  • This paper deals with the effect of teeth number variation in permanent Magnet DC motor. As teeth number varies, both flux density distribution and winding pitch are influenced, which is closely related to torque-speed characteristics, output power, and efficiency. In this study, motor design carried out using finite element method, and prototype motors were manufactured to test their performance analysis. In spite of torque ripple due to cogging effect better characteristic of machine using small teeth number was recorded than the motors with large number of rotor teeth. One of that reasons is caused by adopting large coil-length due to large number of teeth, i. e. large coil-pitch.

  • PDF

시리얼 통신 기반 파라미터 추정에 의한 BLDC모터의 고장검출 (Fault Detection of BLDC Motor Using Serial Communication Based Parameter Estimation)

  • 서석훈;유정봉;우광준
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.45-52
    • /
    • 2002
  • 본 논문에서는 데이터 수집 보드로부터 호스트 컴퓨터로 시리얼 통신 채널을 통하여 전송된 BLDC(Brushless DC)모터의 입력과 출력 정보를 이용하여 모터의 저항값을 추정함으로써 고장을 검출하는 고장검출 시스템을 제안하였다. 프레임 크기가 고정된 프로토콜을 설계하고, 주기적으로 통신이 이루어지도록 하여 시리얼 통신 채널에서 발생되는 대역폭 제한으로 인한 시간지연문제를 해결하였으며, 저항값을 추정하기 위하여 간략화된 BLDC모터 모델과 순환형 최소자승법 알고리즘을 사용하였다. 제안된 고장 검출 방법은 실험을 통하여 성능을 확인하였다.

공정변수에 의한 Ni/Cr/Al/Cu계 박막의 전기적 특성 (The effect of the process parameters on the electrical properties of Ni/Cr/Al/Cu alloy thin film)

  • 이붕주;박상무;박구범;박종관;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.725-728
    • /
    • 2001
  • We have fabricated thin films using the DC/RF magnetron sputtering of 74wt%Ni-l8wt%Cr-4wt%Al-4wt%Cu alloy target and studied the effect of the process parameters on the electrical properties for low TCR(Temperature Coefficient of Resistance) films. In sputtering process, pressure, power and substrate temperature, are varied as controllable parameter. The films are annealed to 400$^{\circ}C$ in air and nitrogen atmosphere. The sheet resistance, TCR of the films increases with increasing annealing temperature. It abruptly increased as annealing temperature increased over 300$^{\circ}C$ in air atmosphere. From XRD, it is found that these results are due to the existence of NiO on film surface formed by annealing. As a results of them, TCR can be controlled by variation of sputter process parameter and annealing of thin film.

  • PDF

속도관측기를 활용한 타여자직류전동기의 적응 백스테핑 제어기 설계 (Adaptive Backstepping Controller Design for a Separately Excited DC Motor Using Speed Observer)

  • 현근호;양혜원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권7호
    • /
    • pp.385-392
    • /
    • 2003
  • A nonlinear speed controller for a separately excited DC motor (SEDCM) based on a newly developed adaptive backstepping approach is presented. To compensate parameter uncertainties and load torque disturbance, a nonlinear adaptive backstepping control law and adaptive law are derived systematically step by step through virtual control input and suitable Lyapunov function. Also, speed observer without using costly speed sensor is presented. Simulation results show that the proposed controller can observe real speed and track the reference speed signal generated by a reference model.