• Title/Summary/Keyword: daylighting systems

Search Result 62, Processing Time 0.025 seconds

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

Comparative Performance Evaluation of Advanced Daylighting Glazing Systems by Scale Model Measurements (축소모형을 이용한 가변 유리투과체의 채광유형별 성능평가 비교)

  • Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • The conventional way to acquire sufficient amount of daylight in interiors is to provide large openings with clear glass. The use of clear glass on the whole facade, however, might cause a sort of visual problem because of the harness of direct sun and brighter sky surface than expected. They should be filtered in opticalway or bounced in the architectural. One of the common solutions for the problem might be the use of photometric glasses with various transmittances for the glass walls. This paper deals with performance data related to the impact of various transmittal glazing materials for window systems in terms of daylighting. A series of scale model measurements was carried out with the fundamental configuration of a commonly used all-glass facades. Additionally some experimental performance index was issued for the better expression of the need of natural lighting.

Economic Feasibility Analysis on the Benefit of Daylighting Incorporation Devices under Clear Skies (주광연동 제어설비를 이용한 청공광의 경제성 평가)

  • Kim, Gon;Kim, Jeong-Tai
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.7
    • /
    • pp.491-499
    • /
    • 2007
  • An architectural means of optimal daylight distribution is by using so-called light shelf systems, horizontal shading and redirecting devices. The overall performance of the daylighting system can be improved by the incorporation with electric lighting control devices. This paper aims to exemplify the benefit of daylighting in term of economic consideration. In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control devices.

An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program (베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로)

  • Lim, Tae Sub;Park, Jong Myung;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

Performance Analysis on Solar Tracking Daylighting Systems Using Different Types of Solar Collectors: Parabolic Dish vs. Fresnel Lens (태양추적식 자연채광 장치의 집광기 종류에 따른 성능 분석: 포물 반사경 vs. 프레넬 렌즈)

  • Kim, Yeongmin;Kim, Won-Sik;Jeong, Hae-Jun;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.1
    • /
    • pp.39-45
    • /
    • 2017
  • This paper presents the effect of solar collectors on the performance of solar tracking daylighting systems. A series of measurements were made for two different types of solar collectors mounted on double axis solar trackers: Parabolic dish concentrator and Fresnel Lens. Indoor light levels were measured at different locations of an office space (longitude: 126.33 E, latitude 33.45 N) as photo sensors were placed on a task plane 80 cm above the floor. To accurately monitor the applicability of the systems, measurements were performed under clear and overcast sky conditions with the roll-screen (on the south window) in the down position. Comparing the illuminance data, the system with Fresnel lens outperformed that of parabolic dish concentrator. On clear days, the former delivered the light levels of 400~600 lux on the task plane whereas the latter recorded 100~200 lux. Depending on the amount of cloud cover, on overcast days, illuminance readings fluctuated to some extent.

A Study on the Sustainable Renovation for the Classroom unit of Elementary school designed by Standard Plan in 1980s (80년대 표준설계 초등학교 단위 교실의 환경친화적 리노베이션에 관한 연구)

  • Park, Ji-Hyun;Rieh, Sun-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.2
    • /
    • pp.25-33
    • /
    • 2006
  • Majority of elementary school in Korea are built by standard plan in 1980s. Being deteriorated and uniform, they have lots of problems to meet the new education curriculum and generate environmental problems in terms of its performances. This research intends to review the conditions of classroom units related with the environmental issues and provide the directions of sustainable renovation to meet the updated curriculum focusing on daylighting and ventilation systems for the classroom built by standard plan in 1980s.

The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds (블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가)

  • Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea (건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향)

  • Lee, Ah-Young
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

Effect of Glazing Systems on Chromaticity and Color Temperature in the Office Room (투과체에 적용된 채광방식이 사무소공간의 색도 및 색온도분포에 미치는 영향 분석)

  • Jeong, In-Young;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.18-26
    • /
    • 2007
  • One basic function of glazing system has always been the maintenance of visual contact with the natural environment-a fundamentally ecological function. In addition, penetration light through glazing system have an effect on variable atmosphere of interior. In this study, a typical office space was selected as a evaluation model and a 1/10 scale model was made. The conventional window, differentiated window and interior lightshelf were designed to enhance daylighting performance. The chromaticity and color temperature of interior space was measured using Prometric 1421. The result showed that transmittance by wavelength range of the glazing had an effect on chromaticity and color temperature. Also, color temperature of indoor environment were increased by $5{\sim}20[%]$ using differentiated window and interior lightshelf. Accordingly, it is thought that the use of a daylighting system will create activate indoor atmosphere.

An Analysis on Development and Application of Solar Sunlighting Systems (첨단 태양광채광시스템의 개발현황 및 활용실태 분석에 관한 연구)

  • Kim, Jeong-Tai;Hwang, Min-Ku;Han, Bong-Soo
    • KIEAE Journal
    • /
    • v.2 no.1
    • /
    • pp.63-68
    • /
    • 2002
  • Solar sunlighting systems are useful to apply for most buildings. This study aims to analysis the development and architectural application of solar sunlighting systems. For the purpose, abroad developing situation of solar sunlighting systems were investigated and analyzed literally. And, by case studies, architectural application methods are analyzed. As results, light pipe systems are mainly used for small building and houses. Also solar mirror systems are used for atrium and underground spaces. Lens-fiber systems are applied for high rise buildings and office buildings which internally have no influx of sunlighting. Some application suggestion in our country are discussed.