• 제목/요약/키워드: daylighting systems

검색결과 62건 처리시간 0.023초

광덕트방식 자연채광 시스템의 산광부에 대한 연구 (A study on lighting Diffusion system of Daylight Duct System)

  • 송규열;박경우;류한기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 2부
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석 (Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model)

  • 백승헌;김정태
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

집광채광시스템을 적용한 실내체육관의 신재생에너지 공급의무 분담률에 관한 연구 (A Study on the Supply obligations allotment rate of New Renewable Energy in Indoor Gymnasiums with the Application of a Daylighting System)

  • 박윤하;이용호;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.27-39
    • /
    • 2015
  • Under the goal of analyzing the compulsory supply share of new renewable energy according to the application of a daylighting system to indoor gymnasiums, this study conducted analysis of energy consumption and operation schedule at three indoor gymnasiums in the nation through a survey. The investigator did an Energy Plus simulation on Building A based on the analysis results and analyzed the supply share of new renewable energy in the saving effects of lighting energy according to the application of a daylighting system. As a result, When 92 prism daylighting system were installed in the upper ceiling of a stadium, they were able to meet the criteria for the minimum illumination for official games(Min : 600㏓) and optimum illumination for general games and recreations, thus saving lighting energy during the daytime(09:00~17:00). The resulting saving effects of lighting energy amounted to 44.4% for official games, 57.6% for general games, and 66.7% for recreations. In addition, the daylighting systems had a compulsory supply share of new renewable energy at 2.04% for official games, 2.75% for general games, and 2.62% for recreations, recording an average compulsory supply share of 2.5%.

공동주택의 공간별 채광실태에 관한 연구 (An Analysis of Daylighting in Each Space of Apartment Houses)

  • 황민구;신혜미
    • KIEAE Journal
    • /
    • 제8권4호
    • /
    • pp.43-48
    • /
    • 2008
  • One of the most important factors in determining the quality of living environment is daylighting. Especially its influence in the psychological and biological life of human beings cannot be underestimated. Therefore, lots of researches have been given to develop a more efficient daylighting system. The sunlighting system, one of many developed systems, has been developed and applied in various ways. However, the high cost of sunlighting system has been the most difficult stumbling-block in making it commercial. However, as domestic apartment houses tend to be more luxury, life environment becomes a very important factor more than cost in building apartment house. Therefore, it would be possible to adopt sunlighting system in the non-window areas such as a restroom in an apartment house. This research is a preliminary work in order to measure a possibility of applying sunlighting system in an apartment house. In order to do so, I measure Sunlight Illuminance Ratio in various areas of apartment house. As a result, in case of a residential-commercial building, areas such as kitchen, restroom, and entrance are relatively weak-lighting areas. In case of a traditional apartment house, restroom and entrance are relatively weak-lighting areas. For that reason, a special lighting support is needed in these areas.

생애주기비용분석 기법을 이용한 채광기능성 창호시스템의 경제성 평가에 관한 연구 (Economic Probation on the Benefit of Daylighting by a Light-Guide System)

  • 김곤;김정태
    • KIEAE Journal
    • /
    • 제6권3호
    • /
    • pp.11-18
    • /
    • 2006
  • Attention on daylighting should be focused not so much on a simple maximization of the natural light available in a space, as on improving the quality of lighting by ensuring as even but intense distribution of illumination in inner areas. An architectural means of optimal daylight distribution is by using so-called light shelf systems, horizontal shading and redirecting devices. The overall performance of the daylighting system can be improved by the incorporation with electric lighting control devices. This paper aims to exemplify the benefit of daylighting in term of economic consideration. In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control devices.

축소모형을 이용한 분할형 유리 투과체 창호시스템의 채광성능실험 (Scale Model Experiment on Daylighting of Differentiated Glazing System)

  • 정인영;김정태
    • KIEAE Journal
    • /
    • 제4권4호
    • /
    • pp.61-68
    • /
    • 2004
  • Daylight is a critical factor in architecture, as it helps enhance the working efficiency and pleasantness of the people working inside, in addition to reduce the power consumption in heating and cooling and make the interior space brighter. There are many kinds of glazing and daylighting systems. At present, research and efforts for their development are carried out, alongside quantitative evaluation. This study aims to present basic materials to be used to design proper glazing and daylighting systems in architecture based on a quantitative evaluation by scale models of existing office buildings. The result of the study can be summarized as follows. 1)As a result of the experiment, it appeared that the ratio of the interior illumination (i.e. at the working table, ceiling and wall) against the outdoor illumination increases at a constant rate, as the transmittance of the glazing goes up. 2) It was found that the SIR(Sunlight Illuminance Ratio) of a separated window system goes up by 20-50% at the rear part than in the case of an ordinary window system.

도서관 열람공간의 방위 및 루버시스템에 따른 주광성능 평가 (An Evaluation of Daylight Performance in the Reading Room of a Library according to Different Azimuths and Louver Systems)

  • 박주현;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.45-51
    • /
    • 2006
  • Recently, various kinds of daylight system are recognized as an important and useful strategy in energy-efficient building designs. However, a large amount of direct sunlight can make many problems. Therefore, it is necessary to control daylighting through louver systems for high quality visual environment. The purpose of this study is to analyze daylighting performance in the reading room of a library according to different azimuths and louver systems. The results evaluated daylight performance based on the RADIANCE lighting software.

Optical Fiber Daylighting System Combined with LED Lighting and CPV based on Stepped Thickness Waveguide for Indoor Lighting

  • Vu, Ngoc Hai;Shin, Seoyong
    • Journal of the Optical Society of Korea
    • /
    • 제20권4호
    • /
    • pp.488-499
    • /
    • 2016
  • We present a design and optical simulation of a cost-effective hybrid daylighting/LED system composed of mixing sunlight and light-emitting diode (LED) illumination powered by renewable solar energy for indoor lighting. In this approach, the sunlight collected by the concentrator is split into visible and non-visible rays by a beam splitter. The proposed sunlight collector consists of a Fresnel lens array. The non-visible rays are absorbed by the solar photovoltaic devices to provide electrical power for the LEDs. The visible rays passing through the beam splitters are coupled to a stepped thickness waveguide (STW) by tilted mirrors and confined by total internal reflection (TIR). LEDs are integrated at the end of the STW to improve the lighting quality. LEDs’ light and sunlight are mixed in the waveguide and they are coupled into an optical fiber bundle for indoor illumination. An optical sensor and lighting control system are used to control the LED light flow to ensure that the total output flux for indoor lighting is a fixed value when the sunlight is inadequate. The daylighting capacity was modeled and simulated with a commercial ray tracing software (LighttoolsTM). Results show that the system can achieve 63.8% optical efficiency at geometrical concentration ratio of 630. A required accuracy of sun tracking system achieved more than ±0.5o . Therefore, our results provide an important breakthrough for the commercialization of large scale optical fiber daylighting systems that are faced with challenges related to high costs.

광튜브와 디쉬형 집광기의 자연채광 성능 예측 및 비교 연구 (A Comparative Study on Daylighting Performance Prediction of Light Tube and Dish Concentrator)

  • 오승진;한현주;천원기
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.124-132
    • /
    • 2012
  • 본 연구에서는 북측창을 가진 강의실 내의 불균형적인 실내 조도차이를 개선하기 위해 두 가지의 자연채광시스템을 적용하였을 경우에 대하여 Photopia를 이용한 성능 시뮬레이션을 수행하였다. 특히, 본 연구에서는 태양고도가 최고 $80^{\circ}$ 이르는 하지에 청천공 상태 하에서의 태양고도에 따른 각 시스템의 배광분포곡선을 구하고 이를 이용하여 실내 조도 등을 분석하였다. 작업면의 경우, 창측과 복도측의 평균 조도차가 1000lx를 초과하였는데 시스템 설치 후에는 그 차이가 상당히 줄어드는 것으로 나타났다. 광튜브 시스템 설치시 906lx에서 603lx로 감소하였으며, 디쉬형 시스템은 308lx까지 줄어들었다. 광튜브의 성능은 태양고도에 영향을 크게 받았으며 디쉬형 집광기는 지속적인 태양추적으로 인하여 태양고도에 관계없이 일정한 성능을 보여주었다.

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.