• Title/Summary/Keyword: daylighting simulation

Search Result 51, Processing Time 0.059 seconds

Artificial Lighting Energy Saving by Daylighting in Office Building (사무소건물에서 자연채광에 의한 조명에너지 절약의 평가)

  • 임병찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.608-613
    • /
    • 2004
  • Artificial lighting accounts for a significant portion of the energy use in office buildings. Therefore, daylighting is considered one of the fundamental design features of energy-efficient buildings. However, complex daylighting simulation tools are not suitable for most designers to help in the decision-making process. This paper provides the results of a simulation analysis to determine the potential energy savings of daylighting effects reducing electrical energy consumption for office building. A whole building simulation tool is used to determine the effects of daylighting on lighting electricity use as well as total electricity use for typical office buildings. It was determined that daylighting does not provide significant additional lighting energy savings when glass transmittance is increased over 0.7 A simplified method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.

A Comparative Evaluation of Daylighting Performance Software : Lumen-Micro, Adeline and Lightscape (채광성능 평가용 시뮬레이션 프로그램의 비교분석)

  • Kim, J.T.;Chung, Y.G.;Moon, G.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.48-56
    • /
    • 2003
  • Three of the leading computer daylighting simulation programs are compared with physical modeling techniques as a means of predicting daylighting performance of interior spaces. Lumen-Micro, Adeline and Lightscape are compared with physical model experiments under clear sky conditions. The comparative evaluations are conducted on analysis of daylight illuminance ratio(%) depending on model types. The estimated average errors are analyzed on 9.4% in Lumen-Micro, 6.3% in Adeline and 3.4% in Lightscape. Therefore, it is proved that three programs are useful for evaluating daylighting performance in our clear sky condition.

Daylighting Performance Evaluation of Lightshelf Window System by Lightscape (Lightscape를 이용한 광선반 창호시스템의 채광성능평가)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.45-52
    • /
    • 2004
  • Simulation of daylighting by computer program is a method to avoid unnecessary efforts in manufacture of its testing models, to reduce its measuring tolerances and be able to provide variations of various weather conditions as well. Many simulation programs on daylighting have been released freely or commercialized for selling, however, a demonstration of their availability and validity as a tool for evaluating daylighting performance is required since each one has its own characteristics. The objectives of this study lie in suggesting an application method of evaluation tools and demonstration of limits and characteristics so as to more easily determine the daylightingperformance in the very initial stages of planning for an arbitrary office space in which windows with daylight access are built. We produced scale model of the general light inducing type side lighting with lightshelfand ceiling, and the luminance (at 78 measuring points) and illuminance (at 84 measuring points) were measured in a clear sky. And a comparison of the measured values and the calculated values from a computer simulation using the Lightscape program was performed.

Study on Comparative Analysis of Daylight Evaluation Tools for Building Environment (건물 주광환경 평가도구의 비교분석에 관한 연구)

  • Park, K.E.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.26-34
    • /
    • 2002
  • Daylighting in building is very important as it has an effect on work performance as well as on their visual health. It is also regarded as a good energy conservation measure in saving energy used for lighting. There are many daylighting evaluation tools such as empirical equations, tables, nomograms, diagrams, protractors, computer simulation, scale models. This study conducted initial daylight measurements to analyze luminous environment in classrooms of elementary school and comparative analysis on three daylighting evaluation tools, such as daylight factor calculation formula, the graphic method with BRE Protractor and computer simulation with Adeline 3.0. It is found that the computer simulation tool produced the closest result to actual measurements of luminous environment in elementary school classroom, and the other simplified tools made appropriate results so that they can be used in the early stage of daylighting design process.

A Study on Simulation of Daylight for Reducing Glare of the Lecture Room's Front Side in University (대학강의실 전면현휘 감소를 위한 주간채광유입 시뮬레이션에 관한 연구)

  • Jeong, Ji-Seok
    • Journal of the Korean housing association
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2013
  • The University students learn their major or a general education in lecture rooms. In these days, lecturer use frequently various multimedia in lecture room. Appropriate control lighting environment in lecture room should be essential and related in efficient studying. Daylighting on front-side of lecture room will cause glare and students are hard to read contents on white-board at their seat. Therefore, in order to preventing glare we simulated daylighting of lecture room with using computer software in this study. Results from simulation and analysis as follows: The first, if students' left-side is east-oriented in lecture room, best daylighting condition about glare in lecture room. The second, architectural designers can use simulation data of daylighting or simulate data in designing university buildings with lecture rooms. Finally, if reducing size of windows (narrow and deep daylight: more closing vertically, from up to down daylighting: more closing horizontally) we will be able to reduce energy from lecture room.

The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program (시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가)

  • Jeong, Yeol-Wha;Lee, Seun-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

Validity of LIGHTSCAPE As a Visualization Tool for Daylighting Performance (자연채광 성능의 가시화도구로서 LIGHTSCAPE의 유용성 평가)

  • 문기훈;김정태
    • Korean Institute of Interior Design Journal
    • /
    • no.37
    • /
    • pp.110-118
    • /
    • 2003
  • Computer simulation is one of the most useful techniques to predict daylighting performance and present visual image. In architectural and interior design practice, the Lightscape is commonly used often to produce persuasive images rather than physically accurate results. Therefore, this study is to validity the Lightscape as daylighting evaluation tool, in particularly performance and realistically visualization. For the purpose, an evaluation test model (12.0m$\times$7.2m$\times$3.0m) of side lighting window with lightshelf was selected. A 1:6 scale plywood physical model was made. Under clear sky condition, illuminance of 84 Interior point were measured. Lightscape was run on a 750 MHz Pentium PC running Windows 2000 under the same sky condition. And a photography image was compared to rendering image. The physical results of interior illuminance were within 8% between the scale model and Lightscape simulation. There were no differences between the photograph image and rendering image by Lightscape in the sight. Lightscape as visualization tool for daylighting performance was validated.

The Evaluation of Daylighting Performances in Museum Exhibition Spaces Using Computer Program RADIANCE (RADIANCE 프로그램을 이용한 미술관 전시공간의 주광 환경 디자인 평가)

  • Kim, Chang-Sung;Chung, Seung-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.77-84
    • /
    • 2009
  • Daylighting is one of the major elements in architectural design. It also plays an important role in the museums focused on displaying artistic works. Many architects have tried to predict daylighting performances in exhibition spaces during the design process of museums. The aims of this study are to present the design methods using the computer program RADIANCE that is available for the evaluations of daylighting performances in indoor space and to help architects design daylighting systems for better exhibition spaces of museums. For this study, Seoul Museum of Art was chosen and it was evaluated the recommended illuminance and the impacts of direct sunlight under the conditions of overcast sky and clear sky with sun. According to simulation results, they indicated that the alternative toplight system(sawtooth shape) was more effective for daylighting of exhibition spaces than the existing toplight system(pyramid shape) and this study showed a method to evaluate daylighting effects in exhibition spaces with various shapes of toplight systems.

A Study on Sunshine Environment with Different Distance between Buildings (인동간격에 따른 일조환경에 대한 연구)

  • 최용석;최지혜;김용식
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

Projecting Performance of a Daylighting Source Based on Its Architectura Applications in the Open-Top Surface Structure (고심도 공간의 건축적 특성에 따른 자연집광 시스템의 조명원적 성능분석)

  • Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A lightcourt design is typically used to address issues concerning aesthetics, feeling, and mood. From the view point of environmental aspect, as an ecological shaft space, it plays a key role in controlling inner quality. In particularly, the lightcourt concept allows the exploitation of daylighting by bring natural light into the center of the building, thus eliminating dark deep spaces. Additionally, the lightcourt shades the inner space in summer. The amount of light available at the base of the lightcourt depends on a number of factors; translucency of the top, reflectance and the geometry of the space. In this paper is to exemplify a lightcourt configuration with a sloped wall. It promises the maximized a sense of freedom and daylighting availability. It is a matter of course that the lightcourt with open-top plays a role as a light source for the adjacent space to the lightcourt. A series of lighting simulation provides performance data of daylighting with changing photometric factors. For the case that a skylight is not available, an electric lighting design with metal halide lamps has been established to create luminous ceiling. As expected, a sloped lightcourt with open-top exposes its superiority of daylighting source. Ancillary considerations to enhance of daylighting potential for the adjacent space have been issued with performance data.