• 제목/요약/키워드: daylight

검색결과 460건 처리시간 0.024초

광센서 조광제어시스템의 폴링주기 결정에 관한 연구 (A Study on Determination of Poiling Period of Daylight Responsive Dimming Systems)

  • 황민구;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.213-216
    • /
    • 2005
  • Recently, energy depleting problem have risen seriously. Many studies of daylight responsive dimming system for saving of lighting energy in office buildings have been done actively. Most of studies are focused on the accuracy. However if the variation of dimming levels is changed too often, occupants would feel uncomfortable. First, illuminance changes which occupants couldn't detect are studied through analyzing foreign studies. Second, workplan illuminance from daylight in each sky condition is measured. Because the dimming level In daylight responsive dimming system is dependent on the workplan illuminance from daylight. In conclusion, the most appropriate polling periods to daylight responsive dimming system for occupant's visual comfort was determined.

  • PDF

An Analysis of Permanantly Shaded Areas and the Defect Rate of Landscape Trees in Apartment Complexes Using Daylight Simulations

  • Park, Sang Wook
    • 인간식물환경학회지
    • /
    • 제23권3호
    • /
    • pp.333-345
    • /
    • 2020
  • Background and objective: The purpose of this study was to provide basic data on trees that can be used for planting design and construction for permanently shaded areas by grasping the growth status of trees according to the daylight conditions of the outdoor spaces of apartment complexes. Methods: On the recently completed apartment complexes, daylight conditions were analyzed by using daylight simulations utilizing Solar Access Analysis of Ecotect Analysis. With a criteria for assessment of tree condition, the defect rate of trees planted in permanently shaded areas and green spaces with good daylight conditions was analyzed to suggest trees applicable to permanently shaded areas. The first tree survey was conducted from November 18, 2019 to February 15, 2020, focusing on trees planted in permanently shaded areas, and the second tree survey of all the trees planted on the study sites including permanently shaded areas was conducted from March 16 to March 30, 2020. Results: Evergreen trees which are classified as shade intolerant trees including Pinus densiflora, Thuja occidentalis, and Abies holophylla showed a higher defect rate of trees among the trees planted in permanently shaded areas. Taxus cuspidata, Zelkova serrata, Cornus kousa, Chionanthus retusus and Acer palmatum which are classified as shade tolerant trees and shade moderate tolerance trees seemed to be able to be used in the plant design of permanently shaded areas in apartment complexes because the trees showed good growth and a low tree defect rate. In addition, although it was excluded from the analysis due to a small number of samples, Sorbus commixta and Prunus cerasifera var. atropurpurea also can be used for planting in permanently shaded areas. Conclusion: The daylight simulation technique used to analyze permanent shaded areas in this study can be used as an analysis tool considering the daylight environment at the stages of design and construction, and additional research will be required to analyze tree growth according to daylight conditions through data accumulation and monitoring by managing records throughout the entire life cycle of trees in the process of planting and maintenance.

창의 형태 및 차양 계획에 따른 다인 병실의 에너지소비량과 주광조도의 평가 및 분석 (Energy Consumptions and Daylight Illumination levels of a Multi-beded Patient Room according to the Window Shapes and Shading)

  • 최창대;권순정;김선숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제18권3호
    • /
    • pp.29-39
    • /
    • 2012
  • Window and shading designs have a great influence on energy consumption and daylighting in buildings. As far as energy is concerned, small window area is advantageous. But it is not good to the patient healing in hospital. So it is important to find out the optimum window shape which is favorable for both energy consumption and patient healing. In this study, annual energy consumption and daylight illumination levels were analyzed according to the window shapes and shading devices for a multi-beded patient room in hospitals. The simulations were conducted for 19 different cases by COMFEN 4.0 computer simulation program. The results of this paper are as follows. First, window to wall area ratio and shading devices have great influences on annual energy consumption. But it is a problem in that they decrease significantly daylight level in bed room. Second, considering the same energy consumption, reducing the width of window rather than the hight of window is desirable for the secure of daylight level. Third, increase of the number of horizontal shade is not desirable in south face of the building for the energy consumption and daylight level. Fourth, sun shade is not necessary in north face of the building for the energy consumption and daylight level.

아트리움의 자연채광 성능 예측용 노모그래프 (Daylighting Performance Nomographs for Toplit Atrium)

  • 김정태;정유근
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.45-50
    • /
    • 2003
  • Today, there are increasing evidences that daylight is essential for health, well-being and productivity. One of the strong contributions, which atria can make to advantages in building, is in allowing the use of daylight. This research is to develop nomographs and to evaluate the daylight performances of toplit atria with louvers. For this purpose, the evaluation models of toplit atria with well indexes of 0.5, 1.0 or 2.0 have been selected through the field surveys of atrium buildings in Seoul area. Also, weather data for solar irradiance and luminous efficacy were gathered from the recently conducted previous researches. The computer simulations were performed under clear sky conditions, using the ADELINE program, and various daylight performances were analyzed by the daylight illumination ratio. Analyzing the simulation results, solar altitude, solar azimuth, and louver angle and louver reflectance were found to be important factors affecting the daylight performance of toplit atria. Using these variables, regression equations have been formulated, and the nomographs, which may predict the daylight performances of toplit atria with louvers, were developed. The developed nomographs were validated through comparing the results of nomograph predictions to the results of scale-model experiments.

주광량의 변화에 따른 LED조명 제어를 통한 에너지 절감량 분석에 관한 연구 (A Study on Energy Savings Analysis by Controling LED Lighting according to the Change of the Amount of Daylight)

  • 함원태;채수용;한수빈;김흥근;정학근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.522-528
    • /
    • 2012
  • Currently, the energy consumption of electric lighting in an office building is accounted for more than 30% of the total energy consumption. In order to reduce the energy consumed by the indoor lighting, the daylight as a natural energy resource can play an important role in energy savings. The daylight can have positive impacts on improvement of work efficiency and productivity, and also make people feel more psychologically stable. Moreover, by using the daylight, we can definitely reduce the energy consumption in office buildings. Thus, the purpose of this study is to determine the LED dimming ratio depending on the ratio by calculating the amount of artificial illumination required according to the change of daylight by using the light simulation software that can quantify and visualize the performance of daylight. As a result, the energy savings could be obtained up to 30%.

  • PDF

최신 자연채광 디자인 사례들 분석 및 그 적용에 관한 연구 - 미국 LEED 인증 공동주택 사례분석을 바탕으로 - (Study on the Analysis and the Application of State-of-the-Art Daylighting Design Cases - Based on the Case Studies of LEED(Leadership in Energy and Environmental Design) Multi-Family housing -)

  • 윤혜경
    • 한국실내디자인학회논문집
    • /
    • 제22권1호
    • /
    • pp.265-273
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art daylighting design among LEED(Leadership in Energy and Environmental Design) multi-family housing cases and to explore the feasibilities for their applications in domestic housing design. Occupants in multi-family houses are reported to consume more electricity power than those in single houses. That may imply the problems of daylighting design in domestic housing design for multi-family houses have better insulation system and less windows and outside walls than single houses. Therefore two systems, daylight delivery system and daylight control system, are scrutinized for daylighting design with LEED cases. The findings show when windows as a daylight delivery system are combined with overhangs, fins, louvers, fenestration materials, speciality fenestration, or interior controls as a daylight control system, the outcome goes with more energy savings and better facade design. Beside those, lightshelves as a daylight delivery system seem to have potentials in domestic multi-family houses with deep plans and less outside walls. Daylighting designs in domestic multi-family houses need to pursue available options more to achieve the integration of energy and aesthetics values.

Modified Split Flux를 이용한 주광률 계산식 적용에 관한 연구 (Application of the Daylight Factor Formula with the Modified Split Flux)

  • 윤수인;윤경;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.39-47
    • /
    • 2014
  • Daylighting has a great effect on people inside the room. It is also closely related to the lighting energy consumption. Daylight factor(DF) is a very important index for evaluation of the daylighting in overcast sky. The objective of this study is to verify the suitability of the Tregenza's Modified Split Flux formula for the calculation of the daylight factor. We compared the daylight factors calculated by two methods; one by a measurement with 1/5 scale model and the other by the Daysim program. We used variables for verification as window wall ratios(WWR) and angles of the sky visible. As a result, daylight factor calculated by Modified Split Flux is similar to the measurement when more daylight enters the inside. And error is significantly increased when the angle of the sky visible is $50^{\circ}$.

소규모 개인 사무실 공간에서 포토센서 적용조건에 따른 디밍 제어효과 분석 (The Influence of Photosensor Configurations on Control Performance of Daylight Dimming Systems in a Small Private Office)

  • 김수영;이지현
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.231-242
    • /
    • 2011
  • This study examines influences of a daylight dimming control system on the variation of indoor illuminance and lighting energy savings in a small office space. Field measurements and a series of computation were performed for typical types of sky conditions in summer. Results indicate that the daylight illuminance under clear and partly-cloudy sky were close to the target illuminance during a majority of time due to a higher ratio of window to wall. However, the target illuminance was not kept successfully due to the variation of photosensor signals which were strongly influenced by desktop illuminance. The system with partially-shielded conditions succeeded to keep target illuminance under clear sky conditions. The system failed under overcast sky conditions since the electric light output from fixtures caused excessive signals to photosensors due to insufficient daylight on a desktop. Unshielded and fully-shielded conditions were not recommended for effective controls of the systems. The influence of lighting fixtures on photosensors should be minimized to achieve successful lighting controls by daylight dimming systems.

광센서 조광제어시스템과 자동롤러쉐이딩 시스템의 통합 제어 소프트웨어 개발 및 알고리즘 (Development and algorithm of Integration Control Software of Daylight Responsive Dimming Systems and Automated Roller Shooing Systems)

  • 홍성관;박병철;김유신;최안섭;이정호
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.20-28
    • /
    • 2008
  • 에너지 자원의 고갈과 환경오염으로 인하여 건축조명 분야에서는 주광을 이용하여 에너지를 절약하는 연구가 활발히 진행되고 있다. 광센서 조장제어시스템은 실내로 입사되는 주광에 따라 인공조명을 자동으로 제어하는 에너지 절약형 시스템으로 쉐이딩 시스템에 의해 주광유입이 차단되어 그 적용성이 미비하다. 자동롤러쉐이딩 시스템은 태양의 변화에 따라 롤러쉐이드의 높이를 자동으로 제어하는 시스템으로 광센서 조광제어시스템과 통합되어 사용될 때, 불쾌한 직사일광은 차단하고 실내로 유용한 주광을 유입함으로써 에너지 절감과 쾌적한 시환경을 제공할 수 있다. 본 연구는 광센서 조광제어시스템과 자동롤러쉐이딩 시스템의 통합을 위하여, 각 시스템의 제어 소프트웨어를 개발하였고 이를 통합하였다.

천공종류 및 롤러쉐이드의 제어된 높이에 따른 주광분포 특성에 관한 연구 (A Study on the Characteristics of Daylight Distributions by Different Sky Conditions and Controlled Roller Shade Heights)

  • 박병철;임지선;김유신;이정호;최안섭
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.18-26
    • /
    • 2009
  • 광센서 조광제어시스템은 주광을 이용하여 인공조명을 제어하는 대표적인 조명제어시스템이다. 그러나 실내에 설치된 고정된 쉐이딩시스템으로 인해 주광유입을 차단함으로써 광센서 조광제어시스템의 현장 적용성은 낮다. 광센서 조광제어시스템의 적용성 및 정확성의 향상을 위해 자동 롤러쉐이딩 시스템과의 통합은 필수적이다. 따라서 본 연구는 롤러쉐이드의 높이에 따른 주광유입분포의 특성을 분석하기 위하여 Mock-up(1/2스케일) 테스트를 시행하였다. Mock-up은 롤러쉐이드가 설치된 2개의 실과 쉐이딩시스템이 없는 1개의 실로 구성되었다. 롤러쉐이드가 설치된 2개의 실 중 1개소는 롤러쉐이드의 높이를 최하단으로 고정하였고, 다른 1개의 실은 태양의 일영각을 기준으로 직사일광의 실내유입깊이를 정하여 산출된 롤러쉐이드의 높이로 제어하였다.