• Title/Summary/Keyword: data reconstruction

Search Result 1,471, Processing Time 0.025 seconds

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

Clinical Studies on Locally Invasive Thyroid Cancer (국소침범한 갑상선암의 임상적 고찰)

  • Kim Young-Min;Lee Chang-Yun;Yang Kyung-Hun;Rho Young-Soo;Park Young-Min;Lim Hyun-Jun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.236-243
    • /
    • 1998
  • Objectives: Local invasion of the thyroid cancer that is invasion of the upper aerodigestive tract, neurovascular structures of the neck and superior mediastinum, is infrequent and comprises of 1-16% of well-differentiated thyroid cancer. However the proximity of the thyroid gland to these structures provides the means for an invasive cancer to gain ready access into theses structures and when invasion occurs, it is the source of significant morbidity and mortality. So locally invasive thyroid cancer should be removed as much as possible, but still much debates have been exist whether the surgical method should be radical or conservative. This study was desinged to evaluate the clinical characteristics and the surgical treatment of the locally invasive thyroid cancer. Material and Methods: At the department of otorhinolaryngology of Hallym university, 10 patients diagnosed as locally invasive thyroid cancer among the 81 patients treated for thyroid cancer between 1991 to 1997 were retrospectively evaluated. Results: Of the 10 patients, 3 patients had histories of previous surgical treatment with or without radiation or radioactive iodine therapy. The site of invasion of thyroid cancer were trachea(7 cases), recurrent laryngeal nerve(5 cases), mediastinal node(5 cases), esophagus(3cases), larynx(3cases), carotid artery(3 cases), pharynx(l case), and other sites(4 cases). The operation techniques included 1 partial laryngectomy and 1 partial cricoid resection, 2 shavings and 3 window resections of the trachea, 1 sleeve resection of the trachea with end-to-end anastomosis and 1 cricotracheoplasty for tracheal invasion, 2 shavings and 1 partial esophagectomies for esophageal invasion, and 1 wall shaving and 2 partial resections with $Gortex^{\circledR}$ tube reconstruction for carotid artery invasion, and so on. Conclusions: These data and review of literature suggest that the surgical method should be perfomed on the basis of individual condition and complete removal of all gross tumor with preservation of vital structures whenever possible will offer a good result.

  • PDF

Quaternary Geology of the Conjunction Area of the Yeongsan and Sampo rivers (영산강 하류와 삼포강 합류부 일대 제4기 지질 연구)

  • Kim, Ju-Yong;Yang, Dong-Yoon;Hong, Sei-Sun;Nahm, Wook-Hyun;Lee, Heon-Jong;Lee, Jin-Young;Kim, Jin-Kwan;Oh, Keun-Chang
    • The Korean Journal of Quaternary Research
    • /
    • v.19 no.1
    • /
    • pp.1-17
    • /
    • 2005
  • This study aims to study the distribution and formation age of Quaternary deposits in the downstream of Yeongsan Estuarine River, encompassing Muan, Illo and Donggang counties. For this purpose the authors examine several borehole data, and step trench survey for excellent profiles was studied in connection with grain size population and magnetic susceptibility. As a result, it is interpreted that the coastal plain of the Yeongsan River was formed by sea level rise after Last Glacial Maximum(LGM). The fore edge/escarpment of coastal terraces distributed 7-10 m asl is assumed to be formed during the last glacial period, while the coastal terraces distributed above 7-10m asl formed during MIS 5a. In addition, the fore edge/escarpment of coastal terraces distributed above 15 m asl is presumed to be have been formed during the stadial of last interglacial period, while the formation age of coastal terraces distributed above 15m(asl) is assumed to be MIS 5e. This formation age can be estimated by the coastal terrace ages of the southeastern coast of Korean Peninsula. The characteristics of Quaternary deposits linked to paleolithic culture will eventually lead to the reconstruction of ecosystem environment of paleolithic peoples.

  • PDF

Relationship between inter-condylar width and inter-maxillary first molar width (과두간 폭경과 상악 제1대구치간 폭경 사이의 관계)

  • Oh, Sang-Chun;Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.214-219
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the correlation between inter-condylar width and inter-maxillary first molar width to present the criteria for prosthetic reconstruction of dental arch width in maxillary and mandibular fully edentulous patients. Materials and Methods: 120 Koreans (60 males and 60 females) who underwent the cone beam computerized tomography (Cone-beam CT) were selected. The Cone-beam CT images were analysed using Invivo 5.1. After reorientation of axis, inter-maxillary first molar width was measured by clicking both mesio-buccal cusp tip of maxillary first molar. And inter-condylar width was measured by clicking both middle points of condyles. The collected data were analysed with SPSS Version 20.0 and statistical significance of the correlation between inter-condylar width and inter-maxillary first molar width was verified by Pearson's correlation analysis. Results: The mean inter-condylar width of Korean was 105.9 mm, and that of male (108.3 mm) was statistically significantly wider than the female (103.4 mm). The inter-maxillary first molar width of Korean was 57.1 mm, and that of male (57.9 mm) was statistically significantly wider than the female (56.2 mm). Pearson's correlation analysis between inter-condylar width and inter-maxillary first molar width showed a Pearson correlation coefficient of 0.614 and statistically significantly positive correlation. Conclusion: Intercondylar width and inter-maxillary first molar width showed positive correlation and the average ratio of inter-condylar with and inter-maxillary first molar width was 1:0.54. Based on the results of this limited study, inter-condylar width can be used as a guide for setting up dental arch width in fully edentulous patient.

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

A Relative Study of 3D Digital Record Results on Buried Cultural Properties (매장문화재 자료에 대한 3D 디지털 기록 결과 비교연구)

  • KIM, Soohyun;LEE, Seungyeon;LEE, Jeongwon;AHN, Hyoungki
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.175-198
    • /
    • 2022
  • With the development of technology, the methods of digitally converting various forms of analog information have become common. As a result, the concept of recording, building, and reproducing data in a virtual space, such as digital heritage and digital reconstruction, has been actively used in the preservation and research of various cultural heritages. However, there are few existing research results that suggest optimal scanners for small and medium-sized relics. In addition, scanner prices are not cheap for researchers to use, so there are not many related studies. The 3D scanner specifications have a great influence on the quality of the 3D model. In particular, since the state of light reflected on the surface of the object varies depending on the type of light source used in the scanner, using a scanner suitable for the characteristics of the object is the way to increase the efficiency of the work. Therefore, this paper conducted a study on nine small and medium-sized buried cultural properties of various materials, including earthenware and porcelain, by period, to examine the differences in quality of the four types of 3D scanners. As a result of the study, optical scanners and small and medium-sized object scanners were the most suitable digital records of the small and medium-sized relics. Optical scanners are excellent in both mesh and texture but have the disadvantage of being very expensive and not portable. The handheld method had the advantage of excellent portability and speed. When considering the results compared to the price, the small and medium-sized object scanner was the best. It was the photo room measurement that was able to obtain the 3D model at the lowest cost. 3D scanning technology can be largely used to produce digital drawings of relics, restore and duplicate cultural properties, and build databases. This study is meaningful in that it contributed to the use of scanners most suitable for buried cultural properties by material and period for the active use of 3D scanning technology in cultural heritage.

The analysis for attributes of OUV of the capital of Shilla Kingdom (세계유산 신라왕경의 탁월한 보편적 가치 속성 분석)

  • KIM, Euiyeon
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.151-174
    • /
    • 2022
  • According to the "Special Act on the Restoration and Maintenance of the Core Relics of the Shilla Kingdom" enacted in 2019, the Shilla Kingdom refers to the capital of Shilla and Unified Shilla period, and refers to Gyeongju, where the king lived, and the nearby area. Shilla Wanggyeong is a heritage registered on the UNESCO World Heritage List in 2000 under the name of Gyeongju Historic Site and belongs to Wolseong District, Hwangnyongsa District, and Daeneungwon District among the five districts registered as Gyeongju Historic Site. Unlike the Namsan and Sanseong districts, the Shilla Kingdom is a heritage consisting mostly of archaeological sites without physical substance. Gyeongju City sought to promote local tourism while providing more direct experiences to visitors by restoring the heritage that constitutes the Shilla Kingdom. Starting with the restoration of Woljeonggyo Bridge in 2005, the Shilla Wanggyeong restoration project began in earnest. Gyeongju City tried to restore the building site on the west side of Donggung Palace and Wolji after Woljeonggyo Bridge, but it was canceled due to opposition from the UNESCO World Heritage Committee. The World Heritage Committee opposed the restoration and recommended a heritage impact assessment for similar projects in the future. During the miscarriage impact assessment procedure, there is an OUV attribute analysis process of the heritage to be evaluated. This study intends to preemptively derive OUV attributes for the Silla Kingdom through literature and overseas case analysis. In the case of literature research, domestic and foreign research data related to the UNESCO World Heritage Convention and World Heritage Management were examined, and in overseas cases, the architectural works of Krakow Historical District, Stonehenge and Abbury Geoseok Ruins in England, and Le Corbusier were analyzed. Through this, the outstanding universal value attributes of the Silla Kingdom were derived. This study is expected to be used as a reference in the process of restoration projects of other heritage constituting the Shilla Kingdom or construction plans in nearby areas in the future and serve as an indicator to improve the management system of the Shilla Kingdom more efficiently from the perspective of world heritage.

Geometry and Kinematics of the Northern Part of Yeongdeok Fault (영덕단층 북부의 기하와 운동학적 특성)

  • Gwangyeon Kim;Sangmin Ha;Seongjun Lee;Boseong Lim;Min-Cheol Kim;Moon Son
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.1
    • /
    • pp.55-72
    • /
    • 2023
  • This study aims to identify the fault zone architecture and geometric and kinematic characteristics of the Yeongdeok Fault, based on the geometry and kinematic data of various structural elements obtained by detailed field survey and anisotropy of magnetic susceptibility (AMS) of the fault rocks. The Yeongdeok Fault extends from Opo-ri, Ganggu-myeon, Yeongdeok-gun to Gilgok-ri, Maehwa-myeon and Bangyul-ri, Giseong-myeon, Uljin-gun, and cuts various rock types from the Paleo-proterozoic to the Mesozoic with a range of 4.6-5.0 km (4.77 km in average) of right-lateral offset or forms the rock boundaries. The fault is divided into four segments based on its geometric features and shows N-S to NNW strikes and dips of an angle of ≥ 54° to the east at most outcrops, even though the outcrops showing the westward dipping (a range of 54°-82°) of fault surface increase as it goes north. The Yeongdeok Fault shows the difference in the fault zone architecture and in the fault core width ranging from 0.3 to 15 m depending on the bedrock type, which is interpreted as due to differences in the physical properties of bedrock such as ductility, mineral composition, particle size, and anisotropy. Combining the results of paleostress reconstruction and AMS in this and previous studies, the Yeongdeok Fault experienced (1) sinistral strike-slip under NW-SE maximum horizontal principle stress (σHmax) and NE-SW minimum horizontal principle stress (σHmin) in the late Cretaceous to early Cenozoic, and then (2) dextral strike-slip under NE-SW maximum horizontal principle stress (σHmax) and NW-SE minimum horizontal principle stress (σHmin) in the Paleogene. It is interpreted that the deformation caused by the Paleogene dextral strike-slip movement was the most dominant, and the crustal deformation was insignificant thereafter.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF