• Title/Summary/Keyword: data generator

Search Result 1,199, Processing Time 0.033 seconds

Implementation of An Automatic Program Generator for Transforming CASE Data Format into CDIF Format (CASE 자료 형식으로부터 CDIF 형식으로 변환하는 프로그램 자동 생성기의 구현)

  • Bae, Sang-Hyun;Nam, Young-Kwang;Shin, Gyu-Sang
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.12
    • /
    • pp.3840-3847
    • /
    • 2000
  • Electronic Industries Association has set a standard format called CDIF(CASE Data Interchange Format) for exchanging information between CASE tools from 1991. If data used on a CASE tool is represented in CDIF format, then any other CASE tools can use the data by translating CDlF format into their own format. In order to do so, each CASE vendor must provide a translator program from CDIF to its own data format or from its own data to CDIF format. In this thesis, we have implemented a source code generator for translating CASE data format into CDIF format only if they provide how data is stored. This automatic program generator generates CDIF statements using data format used in CASE tools, meta information about stored data and CDIF meta information. In the thesis, the automatic program generator has been implemented with Java and Oracle DBMS with JOBC interface in Sun O/S environment.

  • PDF

A Study on the Virtual Data Generator for Simulation in Smart Factory (스마트팩토리에서 시뮬레이션을 하기 위한 가상 데이터 생성기 연구)

  • Moon, Yong-Hyun;Hwang, Seung-Yeon;Shin, Dong-Jin;Kim, Jeong-Joon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.1
    • /
    • pp.131-139
    • /
    • 2021
  • It can be said that smart factory is the most prominent area in the fourth industrial revolution. Developing processes or algorithms required for smart factory requires data values from smart factory, but there are many real challenges in obtaining such data. Therefore, this study developed a data generator that can more realistically simulate data from different processes in smart factory to help research on smart factory. In addition, functions such as setting presets and intuitive UI configurations were developed for the convenience of data creators. This data generator will help you simulate smart factory environments by providing more realistic data easily and simply when you create the different systems needed for smart factory environments.

COMS CADU DATA GENERATION FOR COMS IMPS TEST

  • Seo, Seok-Bae;Ahn, Sang-II
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.88-91
    • /
    • 2008
  • The COMS IMPS (Communication Ocean and Meteorological Satellite IMage Pre-processing Subsystem) is developed for image pre-processing of COMS. For a test of the COMS IMPS, 7 support software are developed in KARI GS using simulated MI/GOCI WB (Wide-Band) data; COMS Fill Adder, MI (Meteorological Imager) CADU generator, GOCI (Geostationary Ocean Colour Imager) CADU generator, COMS CADU combiner, MI SD (Sensor Data) analyzer, GOCI SD analyzer, and COMS DM (Decomposition Module) test harness. This paper explains functions of developed support software and the COMS IMPS test using those software.

  • PDF

Implementation Status of Performance Demonstration Program for Steam Generator Tubing Analysts in Korea

  • Cho, Chan-Hee;Lee, Hee-Jong;Yoo, Hyun-Ju;Nam, Min-Woo;Hong, Sung-Yull
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.63-68
    • /
    • 2013
  • Some essential components in nuclear power plants are periodically inspected using non-destructive examinations, for example ultrasonic, eddy current and radiographic examinations, in order to determine their integrity. These components include nuclear power plant items such as vessels, containments, piping systems, pumps, valves, tubes and core support structure. Steam generator tubes have an important safety role because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear power plant. There is potential that if a tube bursts while a plant is operating, radioactivity from the primary coolant system could escape directly to the atmosphere. Therefore, in-service inspections are critical in maintaining steam generator tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due to its high inspection speed and flaw detectability on non-magnetic tubes. However, it is not easy to analyze correctly eddy current signals because they are influenced by many factors. Therefore, the performance of eddy current data analysts for steam generator tubing should be demonstrated comprehensively. In Korea, the performance of steam generator tubing analysts has been demonstrated using the Qualified Data Analyst program. This paper describes the performance demonstration program for steam generator tubing analysts and its implementation results in Korea. The pass rate of domestic analysts for this program was 71.4%.

Study on Leading-phase Operation Capability of a 770 MW Jumbo Hydro-generator based on Stability Analysis and End-Region Heat Analysis

  • Fan, Zhen-nan;Zhou, Zhi-ting;Li, Jian-fu;Wen, Kun;Wang, Jun;Sun, Zhang;Wang, Tao;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1317-1325
    • /
    • 2018
  • A generator-grid coupling calculation model is established to study the leading-phase operational capability of a 770 MW jumbo hydro-generator in a Chinese ultra-mega hydropower station. The static and dynamic stability of the generator are analyzed and calculated to obtain stability limits under leading-phase operating conditions. Three-dimensional (3D) time-varying nonlinear moving electromagnetic and temperature field models of the generator end-region are also established and used to determine the magnetic field, loss, and temperature of the end-region under the leading-phase operating condition. The simulation results agree with data measured from the actual 770 MW hydro-generator. This paper provides reliable reference data for the leading-phase operation of a jumbo hydro-generator, which will help to improve in the design and manufacture of future hydro-generators.

Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil (보빈코일 와전류신호를 이용한 증기발생기 세관 스케일 두께 측정)

  • Kim, Chang-Soo;Um, Ki-Soo;Kim, Jae-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.545-550
    • /
    • 2012
  • Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

A Comparative Study on Fault Detection Algorithm of AC Generator (교류 발전기의 고장 검출 알고리즘에 관한 비교 연구)

  • Park, Chul-Won;Shin, Kwang-Chul;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.102-108
    • /
    • 2008
  • AC generator plays an important role of power system. The large AC generator fault may lead to large impacts or perturbations in power system. And then the protection of a generator has very important role in maintaining stability in a power system. In present, the DFT(discrete Fourier transform) based RDR(ratio differential relay) had been widely applied to a internal fault of a generator stator winding. But DFT has a serious drawback. In the course of transforming a target signal to frequency domain, time information is lost. DWT uses a time-scale region. This paper proposes an advanced fault detection algorithm using DWT(discrete Wavelet transform) to enhance the drawback of conventional DFT based relaying. To evaluate the performance of the proposed relaying, we used the test data which were sampled with 720 [Hz] per cycle and obtained from ATP(alternative transient program) simulation. And we made a comparative study of conventional DFT based RDR and the proposed relaying.

Technology Trends for Photoresist and Research on Photo Acid Generator for Chemical Amplified Photoresist (포토 레지스트의 기술 동향과 화학 증폭형 포토레지스트에서의 광산 발생제의 연구)

  • Kim, Sung-Hoon;Kim, Sang-Tae
    • Journal of Integrative Natural Science
    • /
    • v.2 no.4
    • /
    • pp.252-264
    • /
    • 2009
  • Lithographic data obtained from PHS(polyhydroxy styrene) having various functionalities were investigated by using a photoacid generator based on diazo and onium type. Chemically amplified photoresist based on the KrF type photoresist was developed by using a photoacid generator and multi-functional resin. Thermal stability for the photoacid generator showed that the increase of loading amount of photoacid generator resulted in the decrease of glass transintion temperature (Tg). The photoacid generators having methyl, ethyl, or propyl group in their cationic structure produced T-top structure in pattern profile due to the effect of acid diffusion during the generation of acid in the resist. The increase of carbon chain length in the anionic structure of photoacid generators resulted in lower pattern resolution due to the interruption of acid diffusion.

  • PDF

Design of Fault Position Detectable Pattern Generator for Built-In Self Test (고장위치 검출 가능한 BIST용 패턴 발생 회로의 설계)

  • 김대익;정진태;이창기;전병실
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.10
    • /
    • pp.1537-1545
    • /
    • 1993
  • In this paper, we design a pattern generator and a fault position detector to implement the proposed fault test algorithms which are Column Weight Sensitive Fault (CWSF) test algorithm and bit line decoder fault test algorithm for performing the Built-In Self Test(BIST) in RAM. A pattern generator consists of an address generator and a data generator. An address generator is divided into a row address generator for effective address and a column address generator for sequential and parallel addresses. A fault position detector is designed to determine whether full occurred or not and to find the position of the fault. We verify the implemented circuits by the simulation.

  • PDF

Equivalency Assessment for an Eddy Current System Used for Steam Generator Tubing Inspection

  • Cho, Chan-Hee;Lee, Tae-Hun;Yoo, Hyun-Ju;Moon, Gyoon-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.258-267
    • /
    • 2015
  • Eddy current testing is widely used for inspecting steam generator tubing in nuclear power plants (NPPs). The inspection technique for steam generator tubing in NPPs should be qualified in accordance with examination guidelines. When the components of a qualified system such as eddy current tester, probe, and data analysis program, are changed, the equivalency of the modified system to the originally qualified system must be verified. The eddy current tester is the most important part of an eddy current testing system because it excites and transmits alternating currents to the probe, receives coil impedance of the probe and generates signals for anomalies. The Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed an eddy current testing system with an eddy current tester and data acquisition-analysis program for inspecting the steam generator tubing in NPPs; this system can be used for an array probe and as a bobbin and rotating probes. The equivalency assessment for the currently developed system was carried out, and we describe the results in this paper.