• 제목/요약/키워드: data generator

검색결과 1,199건 처리시간 0.031초

펄스발전기의 로터다이나믹 설계 (Rotordynamic design of Pulsed Generator)

  • 김영춘;박철현;박희주;문태선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.805-809
    • /
    • 2002
  • The support bearing requires high DN to raise specific energy efficiency for the state of the art rotating machine with high speed. Especially for the system has a big rotor(670 kgf) with high speed(about one million DNs) such as the pulsed generator, the selection of the bearing and lubrication method are very important. So the study for the critical speed of hollow rotor as well in accordance with high speed rotor and a full analysis are needed for rotor bearing system. This paper describes the analysis for rotor bearing system of pulsed generator compared with experimental data. The bearing and lubrication method are discussed as well with experimental data.

  • PDF

수차발전기 상태진단시스템을 이용한 예지보전체계 (Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 김응태;고성호;김현;정용채;최성필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.453-456
    • /
    • 2007
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

전력계통 안정도해석용 발전기제어계의 대표값선정에 관한 연구 (A Study on the Typical Value of Generator Control Systems for Power System Stability Analysis)

  • 문영환;성기철;권태원;송석하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.141-144
    • /
    • 1992
  • A Generator Control Systems data is complcated by the existence of a wide variety of Control system types and by the fact that the values of key parameters may depend upon the generator types and operating conditions. This paper decribes the typical value determination methods for generator control systems using response ratio test and step response test. It can be a practical way to provide and verify data for real power system analysis.

  • PDF

수차발전기 상태진단시스템을 이용한 예지보전체계 (Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 김응태;고성호;김현;정용채;최성필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2006
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

발전기/제어계 특성시험을 통한 제주한림 S/T 모델정수 결정과 전압제어특성 평가 (Cheju Hanlim S/T Model Parameter Determination and Assessment of Voltage Control Loop on the Characteristic Tests of Generator/Excitation System)

  • 김동준;문영환;이금진;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.147-149
    • /
    • 1999
  • This paper deals with the determination of generator/exciter model parameters for a Cheju Hanlim steam turbine unit. Using the recorded data from the generator characteristic tests, the model parameters have been derived and verified by comparing the simulation results and recorded data. In addition to it, the closed-loop performance of voltage control on no-load condition has been assessed in the frequency domain by taking advantage of derived generator/exciter model parameters.

  • PDF

탬플릿 기반 XML 문서 생성기의 설계 및 구현 (A Design and Implementation of XML Document Generator based on Template)

  • 염세훈;방혜자
    • 디지털산업정보학회논문지
    • /
    • 제8권4호
    • /
    • pp.73-81
    • /
    • 2012
  • Web development and Internet technology development bring many kinds of works to web. This is the main reason why XML, document standard is popular. XML in web can be used to express document template or standard. XML with java can be more powerful and general. For example, XML can be used to transmit data and to print data into the screen using Ajax in JSP(Java Server Page) and to make interfaces in android, which is useful to reduce development cycle. However, XML is not easy to learn for the novice. In this paper, we propose the easy and effective way to reduce the learning curve of XML and to make and use XML documents. For the purpose, we suggest template base XML document generation and we design and implement XML document generator based on Template. XML document generator of template-based provides user interface and layout of XML document. So, users can generate XML document easily and effectively.

수차발전기 상태진단시스템을 이용한 예지보전체계 사례 (Report on Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 고성호;정용채;최성필;곽영균;한승열
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.29-34
    • /
    • 2010
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

발전기 예방정비계획 전산화모형 개발에 관한 연구 (A Study on the Development of Generator Maintenance Scheduling Program Package)

  • 원종률;윤용범;박시우;남재현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1374-1381
    • /
    • 1999
  • This paper describes development of a package for generator maintenance scheduling program with user-friendly interactive mode. Generator maintenance scheduling is to select desirable maintenance periods of generators in the given interval satisfying reliability or economic criteria. Window-based system for user-friendly mode and Oracle-based database system for efficient data management are established in our package. Reserve rate levelization and LOLP minimization are performed in calculation mode, which is composed of DLL programs. Many graphs and charts are illustrated for the user-analysis. Operation is carried out by day-based unit, not by week. The case study has been conducted with the data of practical KEPCO power system in 1999 and successfully demonstrated its effectiveness.

  • PDF

마멸에 의해 손상된 증기발생기 전열관의 파열압력 해석 (Analysis of Burst Pressure for Wear-Damaged Steam Generator Tubes)

  • 신규인;박재학
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.16-22
    • /
    • 2003
  • Generally the rupture of steam generator tubes proceeds from significant plastic deformation before failure. In this study, the burst pressures of damaged steam generator tubes were calculated from the plastic instability analysis with the finite element method. Two wear types, flat and circumferential types were considered. An equation for the burst pressure was proposed by using the strength reduction factor and the Svensson equation. The analysis results were compared with the experiment data from published references and they showed a good agreement with the experiment data.

발전기 회전자 권선의 층간단락 진단시스템 개발 (Development of Shorted-Turn Diagnosis system for Generator Rotor Winding)

  • 이영준;김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.742-747
    • /
    • 1999
  • On-line diagnosis system has been developed and is now applied the detection of shorted turns in the field winding of large generator. This system consists of data aquisition system and display PC. The data aquisition system detects voltage waveforms from flux probe sensor installed in the stator slot. The display PC shows theshorted-turn situation of generator rotor winding. A shorted-turn diagnosis test wasperformed on five gas turbine generators at the Seoinchon combined cycle power plant. The test was conducted using an new diagnosis system and digital oscilloscope which can identify the pole location, the slot number and the number of shorted turns within each slot. It is confirmed that results of two systems are very same in the field tests.

  • PDF