• Title/Summary/Keyword: data communication

Search Result 17,456, Processing Time 0.051 seconds

Eager Data Transfer Mechanism for Reducing Communication Latency in User-Level Network Protocols

  • Won, Chul-Ho;Lee, Ben;Park, Kyoung;Kim, Myung-Joon
    • Journal of Information Processing Systems
    • /
    • v.4 no.4
    • /
    • pp.133-144
    • /
    • 2008
  • Clusters have become a popular alternative for building high-performance parallel computing systems. Today's high-performance system area network (SAN) protocols such as VIA and IBA significantly reduce user-to-user communication latency by implementing protocol stacks outside of operating system kernel. However, emerging parallel applications require a significant improvement in communication latency. Since the time required for transferring data between host memory and network interface (NI) make up a large portion of overall communication latency, the reduction of data transfer time is crucial for achieving low-latency communication. In this paper, Eager Data Transfer (EDT) mechanism is proposed to reduce the time for data transfers between the host and network interface. The EDT employs cache coherence interface hardware to directly transfer data between the host and NI. An EDT-based network interface was modeled and simulated on the Linux-based, complete system simulation environment, Linux/SimOS. Our simulation results show that the EDT approach significantly reduces the data transfer time compared to DMA-based approaches. The EDTbased NI attains 17% to 38% reduction in user-to-user message time compared to the cache-coherent DMA-based NIs for a range of message sizes (64 bytes${\sim}$4 Kbytes) in a SAN environment.

A Investment on Wire-wireless Communication Method for Electrical Device Infrastructure Maintenance (전력설비 관리를 위한 무선 및 유선 통신 방법에 관한 고찰)

  • Kim, Young-Eok;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.354-359
    • /
    • 2016
  • Power plants maintenance data is to be sent to management server system via a communication network. In this case, reliable communication network is required. Transmission of the power plants maintenance data is used in the wired communication network or wireless communication network. PLC communication network is a kind of wired communication network. However PLC communication network is easily affected by noise. On the vulnerable areas in power line system, such as a mountain or rural areas, it is difficult to form a power line communication network. For a wireless communication, environment are also influenced factors in wireless communication. Harsh environmental factors are bring the communication characteristic degradation. In such areas it can be used a combination of two networks and in this way the complementary function can be achieved. Power plants are distributed in various regions across the country. The appropriate communication network is needed to maintain the power plant.This study investigated the effect of environment on the wired communication and wireless communication. It would examine a variable factor which is affect to the communication characteristic. We used PLC communication for wired communication network and ZigBee communication for wireless communication network. We investigated the characteristics of a single communication network and it raised the need for a complex communication technology to complement a single communication network.

Ethernet with Virtual Polling Algorithm for real-Time Industrial Communication Network (실시간 산업용 네트워크를 위한 가상 폴링 기반 이더넷 구현)

  • Kim, T. J.;Lee, K. C;Lee, S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.602-605
    • /
    • 2001
  • This paper focus on a method to use Ethernet Network for Industrial Communication Network. Ethernet use the CSMA/CD MAC(Medium Access Control) Protocol at the Data-Link Layer, Which isn't suit for Industrial Communication Network requiring Real-Time Communication, periodic data processing, critical data processing characteristics. In this paper we proposed the Virtual Polling Algorithm at the Application Layer will be solution of using the Ethernet Network for the Industrial Communication Network, Proposed Algorithm terminate the Collision in the network thus Delay Time is reduced and Real-Time Communication will be implemented.

  • PDF

A Study on the Communication Method for a Ship Main Engine Remote Control System (선박 주기관 원격제어시스템을 위한 통신방식에 관한 연구)

  • 류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.894-900
    • /
    • 1998
  • In this paper, a communication method is proposed for the development of a main engine remote control system. The main engine control system compriese three subsystems such as RCS (Remote Control System) BCS (Bridge Control System) and SS (Safety System), Thus it is required to exchange data each other among these subsystems. The communication method has simplified hardware through the minimization of communication components where the interrupt method are employed for receiving and the polling method for transmitting. We discuss a methodology of using a ring buffer for data storage physically which has two buffers virtually for the effective use of memory. This communication method presents a good performance in the system which has rather small numbers of communication data.

  • PDF

On the study of depulication method of communication and Backup device for an Electric Car using Flash Disk and Ethernet (Flash DISK와 Ethernet을 이용한 전동차의 통신 이중화 및 백업장치에 관한 연구)

  • Seo, Won-Yong;Yeon, Jun-Sang;Yang, Oh
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.472-475
    • /
    • 2002
  • This paper presents a high speed ethernet communication and depulication method of communication to prevent decrease of reliability that was generated by high speed communication. Thus communication reliability was improved and this paper was considered that if any physical breakdown of line of communication occurred, other line of communication could operate collect. This paper used Flash memory for setting storage of backup data at Electric Car that have an humidity and a temperature and an impact. also improved reliability and besides matching data format to windows data format realized to confirm application program at PC or note book computer.

  • PDF

Study on optimized positioning of wireless communication equipment for CBTC (CBTC를 위한 무선통신장비의 최적 위치 선정연구)

  • Kim Yun-Bae;Jung Jae-Ok
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1199-1204
    • /
    • 2004
  • In this paper, the DCS (Data Communication System) which is a main part of CBTC (Communication Based Train Control) system is consisted of radio based wireless communication system and optical based wired system. In the radio based wireless communication, the location of AP(Access Point) Enclosure and Antenna shall be optimized for the guaranteed communication channel between wayside and trains either open aired or tunnelled area. This study is introducing the way of determinating optimized positioning the radio based wireless communication equipment in Bundang Line. At this moment, this CBTC project for the KNR's (Korea National Railway) intelligent train control system are in installment phase therefore the simulation data can show only from lab equipment. After the phase I testing, more detailed data can be collected and advanced paper will be issued in a short time.

  • PDF

Industrial Communication Gateway Design of Communications Module Additive layer type (통신 모듈 적층형 산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Nam, Jae Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.133-136
    • /
    • 2019
  • Recently, many industrial devices are facing protocol compatibility problems with external monitoring and control systems. This paper designed an industrial communication gateway that can support the transformation of industrial communication protocol using multi-layered communication module. Industrial communication gateways have a structure that connects individual communication modules using rs485 serial communication to multiple layers. Each communication module consisted of analog data card, a digital data card LAN, and a CAN-enabled card. The main board processor used Atmega micro-processor, and the rs485 serial slot was placed to have a multi-layer communication module structure. These additive layer type communication modules support analog and digital I/O functions and LAN and CAN for wide use in industrial communication control and monitoring.

  • PDF

The Realization of RFID Tag Data Communication System Using CC1020 (CC1020을 이용한 RFID Tag 데이터 통신 시스템 구현)

  • Jo, Heung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.833-838
    • /
    • 2011
  • RFID system in manufacturing industry is used to collect, categorize, and process the data of products. To install RFID system for a large factory, a large amount of wired data communication network is necessary for RS232 communication. If the installed location of RFID system in the factory is changed or extended, a reinstallment is required for the already installed wired data network. A large amount of time/financial reinvestment is necessary for such reinstallation. By using wireless data communication network, however, the initial installation and reinstallation are very simple. In this paper, we implemented a wireless communication system and RFID system. We used the CC1020 chip for wireless communication system and EM4095 chip for RFID system. CC1020 chip enables highly-reliable data communication, and by setting a simple status register, it can switch between transmitting/receiving status and it can choose the desired frequency of either 400 MHz or 900 MHz. Also, Communication range is 50 m, if external antenna is used. EM4095 is a chip for RFID reader system with the carrier frequency of 125 KHz. This chip can implement the reader system by connecting a small number of components. And EM4100 was used for RFID system. EM4100 is read-only type. Atmega128 is used to control a wireless communication system and RFID system. We confirm that the system can communicate without error up to 50 m from sender. In the paper, the circuit diagram and operation program for CC1020 and RFID system are presented. The system used in the experiment is shown in pictures, and the data movement pattern of CC1020 is shown in the diagram, and the performance of each transmission method is presented.

The Study about Agent to Agent Communication Data Model for e-Learning (협력학습 지원을 위한 에이전트 간의 의사소통 데이터 모델에 관한 연구)

  • Han, Tae-In
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.3
    • /
    • pp.36-45
    • /
    • 2011
  • An agent in collaborative e-learning has independent function for learners in any circumstance, status and task by the reasonable and general means for social learning. In order to perform it well, communication among agents requires standardized and regular information technology method. This study suggests data model as a communication tool for various agents. Therefore this study shows various agents types for collaborative learning, designation of rule for data model that enable to communicate among agents and data element of agent communication data model. A multi-agent e-learning system using like this standardized data model should able to exchange the message that is needed for communication among agents who can take charge of their independent tasks. This study should contribute to perform collaborative e-learning successfully by the application of communication data model among agents for social learning.

Relationship among Communication Competence, Communication Types, and Organizational Commitment in Hospital Nurses (병원 간호사의 의사소통 능력, 의사소통 유형, 조직몰입간의 관계)

  • Lee, Hyun-Sook;Kim, Jong-Kyung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.16 no.4
    • /
    • pp.488-496
    • /
    • 2010
  • Purpose: This study was done to explore the relationship in hospital nurses' of communication competence, communication types, and organizational commitment and to provide basic data for developing programs to improve internal communication and to promote nurses' commitment to their organizations. Methods: The participants included 316 nurses who worked in two general hospitals. The tools used for this study were the Global Interpersonal Communication Competence Scale (GICC) and Communication Satisfaction Questionnaire by Downs & Hazen (1981), revised by Seo (2002) and Mowday's tool (1979) for organizational commitment. Data were analyzed using SPSS/PC+12.0. Results: The mean score for communication competence was 3.46, and for organizational commitment, 3.19. For communication types, the mean score for formal communication was 3.18 and informal communication, 2.59. Communication competence had a positive relationship with formal communication (r=.32) and with informal communication (r=.16). Organizational commitment had a positive relationship with formal communication (r=.53), communication competence (r=.30), and informal communication (r=.27). Conclusion: The results indicate the necessity of developing programs to promote nurses' communication competence and also developing a system that will enrich active communication. Systematic and continuous training in communication is also highly recommended.