• Title/Summary/Keyword: data center servers

Search Result 59, Processing Time 0.026 seconds

A Dynamic Task Distribution approach using Clustering of Data Centers and Virtual Machine Migration in Mobile Cloud Computing (모바일 클라우드 컴퓨팅에서 데이터센터 클러스터링과 가상기계 이주를 이용한 동적 태스크 분배방법)

  • Mateo, John Cristopher A.;Lee, Jaewan
    • Journal of Internet Computing and Services
    • /
    • v.17 no.6
    • /
    • pp.103-111
    • /
    • 2016
  • Offloading tasks from mobile devices to available cloud servers were improved since the introduction of the cloudlet. With the implementation of dynamic offloading algorithms, mobile devices can choose the appropriate server for the set of tasks. However, current task distribution approaches do not consider the number of VM, which can be a critical factor in the decision making. This paper proposes a dynamic task distribution on clustered data centers. A proportional VM migration approach is also proposed, where it migrates virtual machines to the cloud servers proportionally according to their allocated CPU, in order to prevent overloading of resources in servers. Moreover, we included the resource capacity of each data center in terms of the maximum CPU in order to improve the migration approach in cloud servers. Simulation results show that the proposed mechanism for task distribution greatly improves the overall performance of the system.

Interoperability of Spatial Data through Open Web Map Server

  • Cho, D.S.;Jang, I.S.;Min, K.W.;Park, J.H.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.488-490
    • /
    • 2003
  • Over the past few years, a number of studies have been made on web map services, which enable the GIS user to access spatial data through the web. They, however, have focused on only implementation techniques separately, such as map client implementation, map server implementation, communication between client and server, and the map data representation. Therefore, it is hard to share and practical use the spatial data, because they does not ensure interoperability in heterogeneous map servers. In this paper, we have designed and implemented the web map server with open architecture, which complies with the standard interfaces proposed by OpenGIS Consortium (OGC). In particular, we have extended the OGC’s interfaces for a map server to support one or more data sources. This paper has contributed to construction and practical use of web map services by newly proposing the method of implementation of a map server, which could be reused regardless of the types of data sources.

  • PDF

Home Health Care Service Using Routine Vital Sign Checkup and Electronic Health Questionnaires (주기적인 생리변수 측정과 전자건강설문을 이용한 재택건강관리서비스)

  • 박승훈;우응제;이광호;김종철
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.469-477
    • /
    • 2001
  • In this Paper. we describe a home health care service using electronic health questionnaires and routine checkup of vital signs Including ECG (Electrocardiography) , blood pressure. and SpO$_2$ (Oxygen Saturation) . This system is for patients at home with chronic diseases, discharged Patients, or any normal people for the Prevention of disease The service requires a home health care terminal and a PC with Interned connection installed at Patient home. The distance health care management center is equipped with a vital-sign and questionnaire interpreter as well as database, Web, and notification servers with UMS (Unified Messaging System). Participating Physician can access the servers at the center using a Web browser running on a PC available to them at any time. These components are linked together through various kinds of data and voice communication channels including PSTN (Public Switched Telephone Network) . CATV(Community Antenna TV) . Interned. and mobile communication network. Following the Physician's direction given to a Patient. he or she uses the home health care terminal to collect vital signs and fill out the questionnaire. When the terminal automatically transmits these data to the management center. the data interpreter and servers at the center process the information fo1lowing the Protocol implemented on the system. Physicians can retrieve and review data corresponding to their Patients and send back their diagnostic reports to the center. UMS at the center delivers the physician 's recommendation to the corresponding patient through the notification server. Patients can also reprieve and review their own records as well as diagnostic reports from physicians. The system Provides a new way of collecting diagnostic information and delivering doctor's recommendation to patients at home for their health management. Future works are needed in the development of new technology for measurements and interpretations of various vital signs .

  • PDF

Parallel Driven Power Supply with Low Cost Hot Swap Controller for Server (저가형 Hot Swap Controller를 가지는 병렬 구동 서버용 전원 장치)

  • Yi, KangHyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.738-744
    • /
    • 2018
  • This paper proposes a low cost hot swap operation circuit of a parallel operation power supply for servers. Hot swap function for server power system is essential in 24 hour operation system such as internet data center, server, factory and etc. Server power supplies used in internet data centers have two or more parallel operations with the hot swap operation. However, the cost of the power supply is high because the controller IC for hot swap operation is very expensive. Therefore, this paper proposes a parallel-operated power supply with a low-cost hot swap controller for servers. The proposed system can operate hot swap function by using discrete devices and reduce the cost by more than 50%. A 1.2kW prototype system is implemented to verify the proposed low cost hot swap controller.

Scheme for Raising Effectiveness of Servers by Log Management of RAID System (RAID 시스템의 Log 관리에 의한 서버효율성 향상기법연구)

  • Park, Woo-Young;Kim, Jae-Jung;Kwack, Kae-Dal;Shin, Seung-Jung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.955-956
    • /
    • 2009
  • 이 Paper는 Server 솔루션에서 사용되는 RAID 컨트롤러가 Disk 상의 에러(Error)를 처리하는 behavior를 분석하고 이를 개선할 수 있는 방법을 제안한다. RAID Level 중에 가장 기본인 RAID 0는 주로 Internet portal site의 Search Engines 이나 Media streaming Servers, 그리고 HD 영상 편집 시스템에서 사용된다. 그러나 Fault tolerance가 지원되지 않기 때문에 Data Volume(logical Disk)의 보존성이 약한 취약점을 가지고 있다. 따라서 이것을 개선하고 Data 보존성을 높일 수 있는 방안을 제시한다.

Harmony Search for Virtual Machine Replacement (화음 탐색법을 활용한 가상머신 재배치 연구)

  • Choi, Jae-Ho;Kim, Jang-Yeop;Seo, Young Jin;Kim, Young-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.26-35
    • /
    • 2019
  • By operating servers, storage, and networking devices, Data centers consume a lot of power such as cooling facilities, air conditioning facilities, and emergency power facilities. In the United States, The power consumed by data centers accounted for 1.8% of total power consumption in 2004. The data center industry has evolved to a large scale, and the number of large hyper scale data centers is expected to grow in the future. However, as a result of examining the server share of the data center, There is a problem where the server is not used effectively such that the average occupancy rate is only about 15% to 20%. To solve this problem, we propose a Virtual Machine Reallocation research using virtual machine migration function. In this paper, we use meta-heuristic for effective virtual machine reallocation. The virtual machine reallocation problem with the goal of maximizing the idle server was designed and solved through experiments. This study aims to reducing the idle rate of data center servers and reducing power consumption simultaneously by solving problems.

A Study on Computer Center Maintenance Savings through NT Server Consolidate Virtualization (NT 서버 통합 가상화를 통한 전산센터 유지보수 절감에 대한 연구)

  • Lee, Yong-Hui;Kim, Hwan-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.11-19
    • /
    • 2014
  • In this paper, we build server consolidate virtualization focusing on NT server dilapidated and through analysis of the effect of this, has been presented the following results. First, it was possible to obtain an increase in the constant temperature constant humidity chamber efficiency by securing the upper surface space for computing data center mounted virtualization integration server servers multiple physical. Second, by the deployment of virtualization of a large server dilapidated, the introduction of new resources and the cost of maintaining computerized data center and reduce power consumption, the reduction of hardware introduction of additional due to the new server deployment it was possible to derive a cost reduction effect. We obtain the reduction of 89% and 79% compared with conventional consumption of cooling and power savings of the top surface, respectively. Integration of NT servers are virtualized can be expected to change in the Green-IT to contribute to providing the maintenance costs of computing centers in the future as well as current. Building a virtualization server integration applied in this paper can be similarly applied to the UNIX system and to integrate the server group other.

LQG design scheme for multiple vibration controllers in a data center facility

  • Kohiyama, Masayuki;Yoshida, Minako
    • Earthquakes and Structures
    • /
    • v.6 no.3
    • /
    • pp.281-300
    • /
    • 2014
  • This study proposes a scheme to design control parameters for a data center facility with a vibration controller on its top floor and a secondary isolation device with its own vibration controller designed to protect vibration-sensitive computer equipment. The aim is to reduce the effects of acceleration and drift from an earthquake on computer servers placed on the isolation device that must operate during a seismic event. A linear elastic model is constructed and the evaluation function of the linear quadratic Gaussian (LQG) control is formulated. The relationship between the control parameters and the responses is examined, and based on the observations, a control parameter design scheme is constructed to reduce the responses of both the building and the computer server effectively.

Whole-genome sequence analysis through online web interfaces: a review

  • Gunasekara, A.W.A.C.W.R.;Rajapaksha, L.G.T.G.;Tung, T.L.
    • Genomics & Informatics
    • /
    • v.20 no.1
    • /
    • pp.3.1-3.10
    • /
    • 2022
  • The recent development of whole-genome sequencing technologies paved the way for understanding the genomes of microorganisms. Every whole-genome sequencing (WGS) project requires a considerable cost and a massive effort to address the questions at hand. The final step of WGS is data analysis. The analysis of whole-genome sequence is dependent on highly sophisticated bioinformatics tools that the research personal have to buy. However, many laboratories and research institutions do not have the bioinformatics capabilities to analyze the genomic data and therefore, are unable to take maximum advantage of whole-genome sequencing. In this aspect, this study provides a guide for research personals on a set of bioinformatics tools available online that can be used to analyze whole-genome sequence data of bacterial genomes. The web interfaces described here have many advantages and, in most cases exempting the need for costly analysis tools and intensive computing resources.

An Efficient Implementation of Mobile Raspberry Pi Hadoop Clusters for Robust and Augmented Computing Performance

  • Srinivasan, Kathiravan;Chang, Chuan-Yu;Huang, Chao-Hsi;Chang, Min-Hao;Sharma, Anant;Ankur, Avinash
    • Journal of Information Processing Systems
    • /
    • v.14 no.4
    • /
    • pp.989-1009
    • /
    • 2018
  • Rapid advances in science and technology with exponential development of smart mobile devices, workstations, supercomputers, smart gadgets and network servers has been witnessed over the past few years. The sudden increase in the Internet population and manifold growth in internet speeds has occasioned the generation of an enormous amount of data, now termed 'big data'. Given this scenario, storage of data on local servers or a personal computer is an issue, which can be resolved by utilizing cloud computing. At present, there are several cloud computing service providers available to resolve the big data issues. This paper establishes a framework that builds Hadoop clusters on the new single-board computer (SBC) Mobile Raspberry Pi. Moreover, these clusters offer facilities for storage as well as computing. Besides the fact that the regular data centers require large amounts of energy for operation, they also need cooling equipment and occupy prime real estate. However, this energy consumption scenario and the physical space constraints can be solved by employing a Mobile Raspberry Pi with Hadoop clusters that provides a cost-effective, low-power, high-speed solution along with micro-data center support for big data. Hadoop provides the required modules for the distributed processing of big data by deploying map-reduce programming approaches. In this work, the performance of SBC clusters and a single computer were compared. It can be observed from the experimental data that the SBC clusters exemplify superior performance to a single computer, by around 20%. Furthermore, the cluster processing speed for large volumes of data can be enhanced by escalating the number of SBC nodes. Data storage is accomplished by using a Hadoop Distributed File System (HDFS), which offers more flexibility and greater scalability than a single computer system.