• Title/Summary/Keyword: data calibration

Search Result 1,810, Processing Time 0.031 seconds

An Exact 3D Data Extraction Algorithm For Active Range Sensor using Laser Slit (레이저 슬릿을 사용하는 능동거리 센서의 정확한 3D 데이터 추출 알고리즘)

  • Cha, Y.Y.;Gweon, D.G.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.8
    • /
    • pp.73-85
    • /
    • 1995
  • The sensor system to measure the distance precisely from the center of the sensor system to the obstacle is needed to recognize the surrounding environments, and the sensor system is to be calibrated thoroughly to get the range information exactly. This study covers the calibration of the active range sensor which consists of camera and laser slit emitting device, and provides the equations to get the 3D range data. This can be possible by obtaining the extrinsic parameters of laser slit emitting device through image processing the slits measured during the constant distance intervals and the intrinsic parameters from the calibration of camera. The 3D range data equation derived from the simple geometric assumptions is proved to be applicable to the general cases using the calibration parameters. Also the exact 3D range data were obtained to the object from the real experiment.

  • PDF

Characteristics of COMS MI Radiometric Calibration

  • Cho, Young-Min
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.71-74
    • /
    • 2006
  • Communication Ocean Meteorological Satellite (COMS) is planned to be launched onto Geostationary Earth Orbit in 2008. The meteorological imager (MI) is one of COMS payloads and has 5 spectral channels to monitor meteorological phenomenon around the Korean peninsular intensively and of Asian-side full Earth disk periodically. The MI has on-board radiometric calibration capabilities called 'blackbody calibration' for infrared channels and 'space look' for infrared/visible channels, and radiometric response stability monitoring device called 'albedo monitor' for visible channel. Additionally the MI has on-board function called 'electrical calibration' for the check of imaging path electronics of both infrared and visible channels. The characterization of MI performance is performed to provide the pre-launch radiometric calibration data which will be used for in-orbit radiometric calibration with the on-board calibration outputs. The radiometric calibration of the COMS MI is introduced in the view point of instrument side in terms of in-orbit calibration devices and capabilities as well as the pre-launch calibration activities and expected outputs.

  • PDF

Surrogate based model calibration for pressurized water reactor physics calculations

  • Khuwaileh, Bassam A.;Turinsky, Paul J.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1219-1225
    • /
    • 2017
  • In this work, a scalable algorithm for model calibration in nuclear engineering applications is presented and tested. The algorithm relies on the construction of surrogate models to replace the original model within the region of interest. These surrogate models can be constructed efficiently via reduced order modeling and subspace analysis. Once constructed, these surrogate models can be used to perform computationally expensive mathematical analyses. This work proposes a surrogate based model calibration algorithm. The proposed algorithm is used to calibrate various neutronics and thermal-hydraulics parameters. The virtual environment for reactor applications-core simulator (VERA-CS) is used to simulate a three-dimensional core depletion problem. The proposed algorithm is then used to construct a reduced order model (a surrogate) which is then used in a Bayesian approach to calibrate the neutronics and thermal-hydraulics parameters. The algorithm is tested and the benefits of data assimilation and calibration are highlighted in an uncertainty quantification study and requantification after the calibration process. Results showed that the proposed algorithm could help to reduce the uncertainty in key reactor attributes based on experimental and operational data.

Calibration Technology for Precise Alignment of Large Flat Panel Displays (대형 평판 디스플레이의 정밀 정렬을 위한 캘리브레이션 기술)

  • Hong, Jun-Ho;Shin, Dongwon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.100-109
    • /
    • 2022
  • In this study, calibration technology that increases the alignment accuracy in large flexible flat panels was studied. For precise of calibration, a systematization of the calibration algorithm was established, and a calibration correction technique was studied to revise calibration errors. A coordinate systems of camera and UVW stage was established to get the global position of the mark, and equations for translational and rotational calibration were systematically derived based on geometrical analysis. Correction process for the calibration data was carried, and alignment experiments were performed sequentially in cases of the presence or absence of calibration-correction. Alignment results of both calibration correction and non-calibration correction showed accuracy performance less than 1㎛. On the other hand, the standard deviation in calibration-correction is smaller than non-calibration correction. Therefore, calibration correction showed improvement of the alignment repeatability.

Video Image Detector Calibration Period Decision (영상검지기 교정주기 설정방안)

  • Lee, Chung-Won;Baik, Nam-Cheol;Song, Young-Hwa;Jang, Jin-Hwn
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.5 s.83
    • /
    • pp.177-185
    • /
    • 2005
  • The accuracy of a video image detector(VID) is gradually reduced due to the various environmental and mechanical factors. But there has been no systematic research about this VID accuracy decreasing. To maintain a proper level of VID accuracy for the advanced traffic management. a regular VID calibration process needs to be introduced. Because of its cost, however. the calibration cannot be performed frequently. Therefore, the method to decide the optimal calibration interval should be studied in details. This study presents two different calibration interval decision methods. Using the invented data collection equipment. some data in the field were collected and analyzed. which were used for the adaptability checking. Although the data were limited. the result is pretty promising. More data needs to be investigated later and this study will help to maintain the data quality of the ITS center.

THE AUTOMATIC CALIBRATION OF KOREAN VLBI NETWORK DATA

  • HODGSON, JEFFREY A.;LEE, SANG-SUNG;ZHAO, GUANG-YAO;ALGABA, JUAN-CARLOS;YUN, YOUNGJOO;JUNG, TAEHYUN;BYUN, DO-YOUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.4
    • /
    • pp.137-144
    • /
    • 2016
  • The calibration of Very Long Baseline Interferometry (VLBI) data has long been a time consuming process. The Korean VLBI Network (KVN) is a simple array consisting of three identical antennas. Because four frequencies are observed simultaneously, phase solutions can be transferred from lower frequencies to higher frequencies in order to improve phase coherence and hence sensitivity at higher frequencies. Due to the homogeneous nature of the array, the KVN is also well suited for automatic calibration. In this paper we describe the automatic calibration of single-polarisation KVN data using the KVN Pipeline and comparing the results against VLBI data that has been manually reduced. We find that the pipelined data using phase transfer produces better results than a manually reduced dataset not using the phase transfer. Additionally we compared the pipeline results with a manually reduced phase-transferred dataset and found the results to be identical.

Weighted Least Square-Based Magnetometer Calibration Method Robust in Roll-Pitch Limited Conditions (롤피치 제한 조건에 강인한 가중 최소자승법 기반 마그네토미터 캘리브레이션 기법)

  • Jeon, Tae-Hyeong;Lee, Jung-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.259-265
    • /
    • 2017
  • Magnetometer calibration must be performed before the use of three-axis magnetometers to ensure the accuracy of orientation estimation. Recently, one of the most popular calibration approaches is the ellipsoid fitting technique due to its high performance in calibration. To date, in fact, performances of the existing ellipsoid fitting methods have been evaluated with full range rotation data. However, in case of the calibration of magnetometers attached to vehicles, ships, and planes, it is very difficult to collect the full range rotation data since their allowable ranges in terms of roll and pitch are limited to small. This constraint may result in serious performance degradation of some ellipsoid fitting algorithms. Therefore, to be practical, this paper proposes a weighted least square-based magnetometer calibration method that is robust in roll-pitch limited conditions. Furthermore, the proposed method is a linear approach and thus is free from the well-known initial value issue in nonlinear approaches. Experimental results show the superiority of the proposed method to other ellipsoid-fitting calibration methods.

Development and Application of the Calibration Method of Individual Building Energy Consumption (개별건물 에너지소비량 보정기법 개발 및 적용방안)

  • Kim, Dongil;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.15-24
    • /
    • 2020
  • Building energy consumption generally depends on living patterns of residents and outdoor air temperature changes. Although outdoor air temperature changes effect on building energy consumption, there is no calibration method for the comparison before and after Green Remodeling or BEMS installation etc., Big data of building energy consumption are collected and managed by 『National Integrated Management System of Building Energy』 in Korea, and they are utilized for the development of a calibration method for individual buildings as shown as the calibration method for small-area building stocks in the previous research. This study aims to develope a calibration method using big data of building energy consumption of individual buildings and outdoor air temperature changes, and to propose application of appropriate calibration methods for individual buildings or small-area building stocks according to the calibration purpose and conditions.

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

The Evaluation of Accuracy for Airborne Laser Surveying via LiDAR System Calibration (시스템 초기화(Calibration)에 따른 항공레이저측량의 정확도 평가)

  • 이대희;위광재;김승용;김갑진;이재원
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.15-26
    • /
    • 2004
  • The calibration for systematic error in LiDAR is crucial for the accuracy of airborne laser scanning. The main error is the misalignment of platforms between INS(Inertial Navigation System) and Laser scanner For planimetrical calibration of LiDAR, the building is good feature which has great changes in height and continuous flat area in the top. The planimetry error(pitch, roll) is corrected by adjustment of height which is calculated from comparing ground control points(GCP) of building to laser scanning data. We can know scale correction of laser range by the comparison of LiDAR data and GCP is arranged at the end of scan angle where maximize the height error. The area for scale calibration have to be large flat and have almost same elevation. At 1000m for average flying height, The Accuracy of laser scanning data using LiDAR is within 110cm in height and ${\pm}$50cm in planmetry so we can use laser scanning data for generating 3D terrain surface, expecically digital surface model(DSM) which is difficult to measure by aerial photogrammetry in forest, coast, urban area of high buildings

  • PDF