• Title/Summary/Keyword: damage controlled test

Search Result 76, Processing Time 0.039 seconds

A study on development of the high-flowable filling material and application in the old tunnel (터널 배면공동 뒤채움재 개발과 노후터널의 적용에 관한 연구)

  • Ma, Sang-Joon;Seo, Kyoung-Won;Bae, Gyu-Jin;An, Sang-Chul;Im, Kyung-Ha
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.3
    • /
    • pp.195-205
    • /
    • 2002
  • Most tunnel damage such as cracks or leakage which exist in tunnel liner commonly, is caused by the cavities that exist behind the tunnel liner, through the tunnel safety inspections. These cavities were analysed to check if they affect the stability of tunnels. This study is on the development of the controlled low-strength and flowable filling material which an be applied to the cavity behind the tunnel lining. The backfilling material studied here is crushed sand and stone-dust which is in cake-state and is a by-product obtained in the producing process of aggregate. Varying the compound mixing ratio, laboratory tests of compression test and chemical analyses were carried out. In addition, the material was applied to an old tunnel for the performance assessment.

  • PDF

Design and Performance Evaluation of Impact Type Actuator Using Magnetic Force (자기력을 이용한 충격형 액추에이터의 설계 및 성능 평가)

  • Min, Hyun-Jin;Lim, Hyung-Jun;Kim, Byung-Kyu;Kim, Soo-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1438-1445
    • /
    • 2002
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes have not been replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope that allows safe maneuverability in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfers momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjustment of impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulations show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

Influence of moisture content on mold development in flue-cured tobacco during storage (저장중 황색종 잎담배의 수분 함량이 곰팡이 발생에 미치는 영향)

  • 조대휘;안동명;민영근;이완남;이경구;이상하
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.11 no.2
    • /
    • pp.241-246
    • /
    • 1989
  • Mold development on leaf tobacco(Flue-cured, var. NC 82) during the storage was examined according to the initial moisture content(MC) of the tobacco. The initial moisture content of the leaf tobacco was controlled as 12,14,16% after redrying. Those were packed in cardboard boxes and stored in a warehouse. Samples were taken monthly from June of 1988 through August of 1989 and were evaluated for mold development (colony count) and MC. The moisture content change in the leaf tobacco of 12, 14 and 16% initial MC was in the range of 11.1-13.3, 12.8-15.3 and 14.9-16.7% and the mean number of colonies from them were 1.4$\times$102, 1.0$\times$102, and 4.0$\times$102 colonies per gram of tobacco, respectively, however mold-damaged leaf tobacco other than the treatments was occasionally observed to have the colony number as high as 2.3$\times$105 colonies per gram of tobacco. In the meantime, the leaf tobacco was stored at 6 relative humidity levels at $25^{\circ}C$ in laboratory test. Leaf tobacco of 15.0-16.4% MC was maintained without the mold-damage after 80 days of storage whereas those of 19.9, 21.3, 25.5 and 27.1% MC became moldy after 50, 15, 11 and 6 days of storage, respectively.

  • PDF

A study on the adhesion of Ag film deposited on Alloy42 substrate (Alloy42 기판 위에 증착된 Ag막의 밀착력에 관한 연구)

  • 이철룡;천희곤;조동율;이건환;권식철
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.4
    • /
    • pp.496-502
    • /
    • 1999
  • Electroplating of Ag and Au on the functional area of lead frames are required for good bonding ability in IC packaging. As the patterns of the lead frame become finer, development of new deposition technology has been required for solving problems associated with process control for uniform thickness on selected area. Sputtering was employed to investigate the adhesion between substrate Alloy42 and Ag film as a new candidate process alternative to conventional electroplating. Coating thickness of Ag film was controlled to 3.5$\mu\textrm{m}$ at room temperature as a reference. The deposition of film was optimized to ensure the adhesion by process parameters of substrate heating temperature at $100~300^{\circ}C$, sputter etching time at -300V for 10~30min, bias voltage of -100~-500V, and existence of Cr interlayer film of $500\AA$. The critical $load L_{c}$ /, defined as the minimum load at which initial damage occurs, was the highest up to 29N at bias voltage of -500V by scratch test. AFM surface image and AES depth profile were investigated to analyze the interface. The effect of bias voltage in sputtering was to improve the surface roughness and remove the oxide on Alloy42.

  • PDF

A Study on the Fluid Mixing Analysis for the Shell Wall Thinning Mitigation by Design Modification of a Feedwater Heater Impingement Baffle (급수가열기 충격판 설계변경에 따른 동체감육 완화에 관한 유동해석 연구)

  • Kim K. H.;Hwang K. M.;Jin T. E.
    • Journal of the Korea Society for Simulation
    • /
    • v.14 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • Feedwater heaters of many nuclear power plants have recently experienced wall thinning damage, which will increase as operating time progresses. As it is judged that the wall thinning damages have generated due to local fluid behavior around the impingement baffle installed in downstream of the high pressure turbine extraction steam line to avoid colliding directly with the tubes, numerical analyses using PHOENICS code were performed for two models with original clogged impingement baffle and modified multi-hole impingement baffle. To identify the relation between wall thinning and fluid behavior, the local velocity components in x-, y-, and z-directions based on the numerical analysis for the model with the clogged impingement baffle were compared with the wall thickness data by ultrasonic test. From the comparison of the numerical analysis results and the wall thickness data, the local velocity component only in the y-direction, and not in the x- and z-direction, was analogous to the wall thinning configuration. From the result of the numerical analysis for the modified impingement baffle to mitigate the shell wall thinning, it was identified that the shell wall thinning may be controlled by the reduction of the local velocity in the y-direction.

  • PDF

Control effect and mechanism investigation on the horizontal flow-isolating plate for PI shaped bridge decks' VIV stability

  • Li, Ke;Qian, Guowei;Ge, Yaojun;Zhao, Lin;Di, Jin
    • Wind and Structures
    • /
    • v.28 no.2
    • /
    • pp.99-110
    • /
    • 2019
  • Vortex-Induced-Vibration (VIV) is one kind of the wind-induced vibrations, which may occur in the construction and operation period of bridges. This phenomenon can bring negative effects to the traffic safety or can cause bridge fatigue damage and should be eliminated or controlled within safe amplitudes.In the current VIV studies, one available mitigation countermeasure, the horizontal flow-isolating plate, shows satisfactory performance particularly in PI shaped bridge deck type. Details of the wind tunnel test are firstly presented to give an overall description of this appendage and its control effect. Then, the computational-fluid-dynamics(CFD) method is introduced to investigate the control mechanism, using two-dimensional Large-Eddy-Simulation to reproduce the VIV process. The Reynolds number of the cases involved in this paper ranges from $1{\times}10^5$ to $3{\times}10^5$, using the width of bridge deck as reference length. A field-filter technique and detailed analysis on wall pressure are used to give an intuitive demonstration of the changes brought by the horizontal flow-isolating plate. Results show that this aerodynamic appendage is equally effective in suppressing vertical and torsional VIV, indicating inspiring application prospect in similar PI shaped bridge decks.

A Comparative Evaluation of Closed and Open Kinetic Exercises in the Management of Chronic Ankle Instability

  • Jung, Namjin
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.4
    • /
    • pp.2212-2220
    • /
    • 2020
  • Background: Repetitive damage to the ankle joint causes chronic ankle instability, and studies comparing the effects of exercise in open and closed chains as a treatment method are very rare. Objectives: To investigate the effects of open and closed kinetic exercises on muscle activity and dynamic balance of ankle joint in adults with chronic ankle instability. Design: Single-blind randomized controlled trial. Methods: The selected 30 subjects are randomly divided into open kinetic chain exercise experimental group (EGI, n=10), closed kinetic chain exercise experimental group (EGII, n=10), and stretching control group (CG, n=10). Open and closed kinetic exercises lasted 30 minutes three times a week for six weeks and stretching exercises performed four actions for 20 seconds and five sets. The measurement tools using surface electromyography to measure muscle activity in the ankle joint. The dynamic balance of the ankle was evaluated using the Y-Balance test. Results: Following the intervention, closed and open kinetic chain exercise group showed significant difference in tibialis anterior and gastrocnemius muscle activity and dynamic balance (P<.05). However, no significant difference in tibialis anterior and gastrocnemius muscle activity and dynamic balance between closed and open kinetic chain exercise group (P<.05). Conclusion: This study provides evidence that closed and open kinetic chain exercise can be presented as an effective exercise for the muscle activity of ankle muscle and dynamic balance of the subject with chronic ankle instability.

FE model updating and seismic performance evaluation of a historical masonry clock tower

  • Gunaydin, Murat;Erturk, Esin;Genc, Ali Fuat;Okur, Fatih Yesevi;Altunisik, Ahmet Can;Tavsan, Cengiz
    • Earthquakes and Structures
    • /
    • v.22 no.1
    • /
    • pp.65-82
    • /
    • 2022
  • This paper presents a structural performance assessment of a historical masonry clock tower both using numerical and experimental process. The numerical assessment includes developing of finite element model with considering different types of soil-structure interaction systems, identifying the numerical dynamic characteristics, finite element model updating procedure, nonlinear time-history analysis and evaluation of seismic performance level. The experimental study involves determining experimental dynamic characteristics using operational modal analysis test method. Through the numerical and experimental processes, the current structural behavior of the masonry clock tower was evaluated. The first five experimental natural frequencies were obtained within 1.479-9.991 Hz. Maximum difference between numerical and experimental natural frequencies, obtained as 20.26%, was reduced to 4.90% by means of the use of updating procedure. According to the results of the nonlinear time-history analysis, maximum displacement was calculated as 0.213 m. The maximum and minimum principal stresses were calculated as 0.20 MPa and 1.40 MPa. In terms of displacement control, the clock tower showed only controlled damage level during the applied earthquake record.

A Study on the Stability of Deep Tunnels Considering Brittle Failure Characteristic (취성파괴특성을 고려한 심부터널의 안정성 평가기법 연구)

  • Park, Hyun-Ik;Park, Yeon-Jun;You, Kwang-Ho;Noh, Bong-Kun;Seo, Young-Ho;Park, Chan
    • Tunnel and Underground Space
    • /
    • v.19 no.4
    • /
    • pp.304-317
    • /
    • 2009
  • Most crystalline rocks have much higher compressive strength than tensile strength and show brittle failure. In-situ rock mass, strong enough in general sense, often fails in brittle manner when subjected to high stress exceeding strength in due of geometrically induced stress concentration or of high initial stress. Therefore, it is necessary to verify the brittle failure characteristics of rock and rock mass for proper stability assessment of underground structures excavated in great depths. In this study, damage controlled tests were conducted on biotite-granite and granitic gneiss, which are the two major crystalline rock types in Korea, to obtain the strain dependency characteristics of the cohesion and friction angle. A Cohesion-Weakening Friction-Strengthening (CWFS hereafter) model for each rock type was constructed and a series of compression tests were carried out numerically while varying confining pressures. The same tests were also conducted assuming the rock is Mohr-Coulomb material and results were compared.

Prediction of Brittle Failure within Mesozoic Granite of the Daejeon Region (대전지역 중생대 화강암 암반 내 취성파괴 예측연구)

  • Jang, Hyun-Sic;Choe, Mi-Mi;Bae, Dae-Seok;Kim, Geon-Young;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.357-368
    • /
    • 2015
  • Brittle failure of Mesozoic granite in the Daejeon region is predicted using empirical analysis and numerical modeling techniques. The input parameters selected for these techniques were based on the results of laboratory tests, including damage-controlled tests. Rock masses that were considered to be strong during laboratory testing were assigned to "group A" and those considered to be extremely strong were assigned to "group B". The properties of each group were then used in the analyses. In-situ stress measurements, or the ratio of horizontal to vertical stress (k), were also necessary for the analyses, but no such measurements have been made in the study area. Therefore, k values of 1, 2, and 3 were assumed. In the case of k=1, empirical analysis and numerical modeling show no indication of brittle failure from the surface to1000 m depth. When k=2, brittle failure of the rock mass occurs at depths below 800 m. For k=3, brittle failure occurs at depths below 600 m. Although both the Cohesion Weakening Friction Strengthening (CWFS) and Mohr-Coulomb models were used to predict brittle failure, only the CWFS model performed well in simulating the range and depth of the brittle failure zone.