DOI QR코드

DOI QR Code

Design and Performance Evaluation of Impact Type Actuator Using Magnetic Force

자기력을 이용한 충격형 액추에이터의 설계 및 성능 평가

  • 민현진 (한국과학기술원 기계공학과) ;
  • 임형준 (한국과학기술원 기계공학과) ;
  • 김병규 (한국과학기술연구원 마이크로시스템센터) ;
  • 김수현 (한국과학기술원 기계공학과)
  • Published : 2002.07.01

Abstract

For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes have not been replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope that allows safe maneuverability in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfers momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjustment of impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulations show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

Keywords

References

  1. Takaharu Idogaki, Hitoshi Kanayama, Nobuyuki Ohya, 1995, 'Characteristics of Piezoelectric Locomotive Mechanism for an In-Pipe Micro Inspection Machine,' Sixth International Symposium on Micro Machine and Human Science, pp. 193-198 https://doi.org/10.1109/MHS.1995.494237
  2. Shigeo Hirose, Hidetaka Ohno, Takeo Mitsui, and Kiichi Suyama, 1999, 'Design of In-pipe Inspection Vehicles for ${\verphi}25$, ${\verphi}50$, ${\verphi}150$ pipes,' Proceedings of 1999 IEEE International Conference on Robotics & Automation, pp. 2309-2314 https://doi.org/10.1109/ROBOT.1999.770450
  3. Sanjiv Kumar, Irwan M. Kassim and Vijayan K. Asari, 2000, 'Design of a Vision-Guided Micro Robotic Colonoscopy System,' Advanced Robotics, Vol. 14, No.2,pp.87-104 https://doi.org/10.1163/156855300741465
  4. Dario, P., Carrozza, M. C., Lencioni, L., Magnani, B., D'attanasio, S., 1997, 'A Micro Robotic System for Colonoscopy,' Proceedings of the 1997 IEEE international Conference on Robotics and Automation , pp. 1567-1572 https://doi.org/10.1109/ROBOT.1997.614363
  5. Jangmoo Lee, Jonghyun Kim, Sangwon Lee, Junghyung Park, 1999, 'The research of development and control for the micro endoscope,' KSPE. Vol. 16, No.2, pp. 15-21
  6. Jungun Jang, Junggyung Kim, 1999, 'The development of the micro endoscope system for the blood vessel,' Journal of KSTLE, Vol. 15, No.3, pp. 272-277
  7. Gregersen, H., Emery, J. and McCulloch, A. M., 1998, ' History-Dependent Mechanical Behavior of Guinea-Pig Small Intestine,' Annals of Biomedical Engineering, Vol. 26, pp. 850-858 https://doi.org/10.1114/1.109