• Title/Summary/Keyword: dB difference

Search Result 1,889, Processing Time 0.035 seconds

A Study of Traffic Noise Characteristics on the National Highways (일반국도의 교통소음특성에 관한 연구)

  • Son, Hyeon Jang;An, Deok-Soon;Baek, Cheolmin;Kwon, Soo-Ahn;Lee, Jaejun
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.11-18
    • /
    • 2013
  • PURPOSES : This study presents the noise level and frequency characteristics investigated in the national highways with the consideration of various measuring conditions and/or methods. METHODS : The noise levels on the asphalt concrete pavement(ACP) and the jointed plain concrete pavement(JPCP) of the national highway were measured and analysed with respect to three variables, i.e., pavement type, surface condition, and measurement distance. The PASS-By method is utilized for the noise measurement and then using CPB spectrum analysis method with 1/3 octave bandwidth, the noise levels and frequency characteristics were calculated for two-second periods before and after the peak noise. RESULTS : Depending on the pavement type, the noise level was changed as the average noise levels are 73.3dB(A) and 78.3dB(A) for ACP and JPCP, respectively. With respect to the effect of surface condition, the average noise levels for crack H(high), M(medium), and L (low) sections are 77.4dB(A), 77.4dB(A), and 78.1dB(A), respectively. Regarding the measurement distance, 1.2meter difference in measuring location reduces 1.6dB(A) of noise level; the average noise levels at 5.3m and 7.5m from the centerline of outer lane are 72.8dB(A) and 71.2dB(A), respectively. It should be noted that the noise levels are slightly different as a function of vehicle speed and type. However, the overall trends for each case was similar. It was found that the domain frequency bands for ACP and JPCP were 400Hz~2000Hz and 500Hz~2000Hz, respectively. CONCLUSIONS : Based on the analysis with the measured noise date from national highway, it was concluded that the noise level and frequency band vary depending on the various conditions. It was also found that some variables significantly affect the noise level while others do not. With further systematic investigation, the comprehensive noise characteristics on the national highway can be achieved. Using such database, it is possible to develop the fundamental noise reduction technology.

A Study on A Mathematical Formulation of Protection Ratio and Its Calculation for Fixed Radio Relay System with Diversity (다이버시티를 갖는 고정 무선 중계 시스템에 대한 보호비의 수학적 표현과 계산에 대한 연구)

  • Suh Kyoung-Whoan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.358-367
    • /
    • 2006
  • In this paper, a mathematical formulation of protection ratio and its calculation method are suggested for a radio relay system with diversity techniques. The analysis of protection ratio and its physical meaning have been performed for the space or frequency diversity system, and in particular protection ratios are reviewed in terms of the parameters of diversity improvement factor, which comprises antenna gain, separation distance between antennas, frequency and its difference between carriers, and distance. As one of simulated results, the co-channel protection ratio of 60 dB is obtained for the space diversity system regarding 6.2 GHz, 60 km, 64-QAM, and 25 m between antennas, which gives 15 dB less than the co-channel protection ratio of the non-space diversity system. In addition, the co-channel protection ratio for the frequency diversity system gives 64 dB in case of frequency offset of 0.5 GHz under the same conditions as the space diversity system, which brings about 11 dB less than the co-channel protection ratio of non-frequency diversity system. In consequency, it is interesting to note that the space diversity system is less sensitive to interference in comparison to the frequency diversity system and provides better quality of service for a given interference.

Direct blast suppression for bi-static sonar systems with high duty cycle based on adaptive filters (고반복률을 갖는 양상태 소나 시스템에서의 적응형 필터를 이용한 송신 직접파 제거 연구)

  • Lee, Wonnyoung;Jeong, Euicheol;Yoon, Kyungsik;Kim, Geunhwan;Kim, Dohyung;You, Yena;Lee, Seokjin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.446-460
    • /
    • 2022
  • In this paper, we propose an algorithm to improve target detection rate degradation due to direct blast in a bi-static sonar systems with high duty cycle using an adaptive filters. It is very important to suppress the direct blast in the aforementioned sonar systems because it has a fatal effect on the actual system operation. In this paper, the performance was evaluated by applying the Normalized Least Mean Square (NLMS) and Recursive Least Square (RLS) algorithms to the simulation and sea experimental data. The beam signals of the target and direct blast bearings were used as the input and desired signals, respectively. By optimizing the difference between the two signals, the direct blast is removed and only the target signal is remained. As a result of evaluating the results of the matched filter in the simulation, it was confirmed that the direct blast was removed to the noise level in both Linear Frequency Modultated (LFM) and Generalized Sinusoidal Frequency Modulated (GSFM), and in the case of GSFM, the target sidelobe decreased by more than 20 dB, thereby improving performance. In the sea experiment, it was confirmed that the LFM reduced the level of the transmitted direct wave by 10 dB, the GSFM reduced the level of the transmitted direct wave by about 4 dB, and the side lobe of the target decreased by about 4 dB, thereby improving the performance.

Study of Variation of Internal Taget Volume between 4DCT and Slow-CT in Respiratory Patterns Using Respiratory Motion Phantom (호흡 동조 구동 팬톰을 이용한 호흡패턴에 따른 4DCT, Slow-CT의 내부표적체적 변화 연구)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Ji, Young Hoon;Kim, Mi-Sook;Yoo, Hyoung Jun;Kim, Chan Hyeong;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.53-63
    • /
    • 2014
  • The objective of this study is to investigate the difference of ITV lengths and ITVs between 4DCT and Slow-CT images according to respiratory patterns using a respiratory motion phantom. The respiratory periods 1~4 s and target motion 1~3 cm were applied on each respiratory pattern. 4DCT and Slow-CT images were acquired for 3 times. 4DCT and Slow-CT ITVs were measured with contouring the target in the Eclipse RTP system. The measured ITV lenghts and ITVs in 4DCT and Slow-CT images were compared to the known values. For the ITV lengths and ITVs in the 4DCT, the difference of them were reduced as the respiratory period is longer and target motion is shorter. For the Slow-CT, there was same tendency with change in 4DCT ITV lengths and ITVs about target motion. However, the difference of ITV lengths and ITVs for the respiratory periods were the lowest in respiratory period 1 second and different slightly within respiratory period 2-4 seconds. According to the respiratory patterns, pattern A had the highest reproducibility. Pattern B, C and D were showed the difference similar to each other. However, for pattern E, the reproducibility was the lowest compared with other four patterns. The difference of ITV lengths and ITVs between Slow-CT and 4DCT was increased by increasing the respiratory periods and target motion for all respiratory patterns. When the difference of Slow-CT ITV lengths and ITVs were compared with that of 4DCT ITV lengths and ITVs, Slow-CT ITV lengths and ITVs were approximately 22 % smaller than 4DCT, and the representations of target were different in each pattern. In case of pattern A, B and C, length difference was 3 mm at S (superior) and I (inferior) direction, and the length difference of pattern D was 1.45 cm at only "I" direction whereas the length difference of pattern E was 5 mm longer in "S" direction than "I" direction. Therefore, the margin in SI directions should be determined by considering the respiratory patterns when the margin of Slow-CT is compensated for 4DCT ITV lengths. Afterward, we think that the result of this study will be useful to analyze the ITV lengths and ITVs from the CT images on the basis of the patient respiratory signals.

The Variation of Serum Thyroglobulin Measured after Thyrogen Administration (Thyrogen 투여 후 측정된 Thyroglobulin 농도변화)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.80-83
    • /
    • 2018
  • Purpose Assessment of Serum Thyroglobulin (sTg) value in total thyroidectomy patients having an ablation dose of radioactive iodine indicates remaining cancer or metastasis. Especially, sTg in patients on withdrawal thyroxine or thyrogen administration for radioiodine ablation is an important indicator to determine the direction of further treatment and prognosis. Current guidelines suggest measurement of sTg is performed at 72 hours after the last injection of thyrogen. and assumes that sTg reaches maximum serum levels at that time. The purpose of this study is to evaluate the variation of sTg measured after thyrogen administration. Materials and Methods We compared with sTg performed at 24hours(D0) and 72hours(D2) after the last injection of thyrogen. We reviewed D0 and D2 from 276 patients were divided them into three groups according to ablation dose of radioactive iodine, 5mCi(A group), 30~80mCi(B group) and 100~200mCi(C group). We used T-test for comparison between D0 and D2. sTg was measured in serum using immunoradiometric assay (Tg-plus RIA; BRAHMS, Berlin, Germany). Results There is no critical variation between D0 and D2 in A group(n=100)(P=0.32), The case of increase(D2>D0) is 45, no change(D2=D0) is 23, decrease(D2D0 is 91, D2=D0 is 28, D2D0 is 19, D2=D0 is 2. The biggest increase is 143.6 ng/mL from 98.4 to 242. Conclusion There was a significant difference in the group over 30mCi. and the case of D2>D0 is 45%, 58.7%, 90.5% for each group. therefore, D2 increased as the dose of radioactive iodine increased. Furthermore, the most sTg values of D0 and D2 are variation under 2.0 ng/mL, so reproducibility as well as sensitivity of sTg will be important at values below 2ng/mL.

Children's Representations of Numbers

  • Park, Han-Shick
    • Research in Mathematical Education
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1997
  • We discuss some aspects of mathematics for teachers such as algebra for teachers, geometry for teachers, statistics for teachers, etc., which can be taught in teacher preparation courses. Mathematics for teachers should consider the followings: (a) Various solutions for a problem, (b) The dynamics of a problem introduced by change of condition, (c) Relationship of mathematics to real life, (d) Mathematics history and historical issues, (e) The difference between pure mathematics and pedagogical mathematics, (f) Understanding of the theoretical backgrounds, and (g) Understanding advanced mathematics.

  • PDF

Assessment of Cellular Proliferation in Oral Verrucous Carcinoma and Well-Differentiated Oral Squamous Cell Carcinoma Using Ki67: A Non-Reliable Factor for Differential Diagnosis?

  • Zargaran, Massoumeh;Eshghyar, Nosratollah;Baghaei, Fahimeh;Moghimbeigi, Abbas
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5811-5815
    • /
    • 2012
  • Background: Non-invasive oral verrucous carcinoma (OVC) and invasive well-differentiated oral squamous cell carcinoma (OSCC) have similar histopathologic findings but different biological behavior. These two malignancies must be correctly differentiated by pathologists. The aim of this study was to determine immunohistochemical (IHC) expression of Ki67 in OVC and well-differentiated OSCC. Methods: Expression of Ki67 was evaluated by IHC in 15 cases of epithelial hyperplasia with no dysplasia (A group), 15 cases of OVC (B group), 12 cases of microinvasive OSCC(C group) and 15 cases of well-differentiated OSCC (D group). Results: There was a significant difference in Ki67 expression based on pattern distribution of immunostaining positive cells, with quantitative and semi-quantitative analyses, among the four groups ; also, between A group and each of the other three groups (P=0.0001). But there was no significant difference between B and C, C and D, and B and D groups (P>0.05). Conclusions: The three evaluation methods of Ki67 expression showed Ki67 (Mib-1) is not a good immunohistochemical marker to assess invasion status and differentiate OVC from well-differentiated OSCC; also, it cannot be used as a diagnostic tool to distinguish between variants of OSCC with similar grade.

A Case Study on Grouping in Peer Tutoring Discourse (또래교수 담론에서의 집단 구성에 관한 사례 연구)

  • Kim, Ga-Hyun
    • Journal of the Korean School Mathematics Society
    • /
    • v.18 no.3
    • /
    • pp.281-309
    • /
    • 2015
  • The purpose of this study is provides an implication of further teaching learning process by analyze the common and difference and characteristic of mathematical self-efficiency between three peer tutoring groups discourse in the mathematical teaching leaning process that use peer tutoring. To achieve this goal, three groups formed that consist of one peer tutor who received a first grade of mathematic achievement and one peer student. Peer student of each group is divided into high grade, middle grade, low grade of mathematic achievement. Then analyze the discourse in the exponential function problem solving process. Based on the results of study, this paper provides a concrete example of merit of peer tutoring on the peer tutor. Result of study also provides a practical help to make a peer tutoring group by considering a difference of grades between peer tutor and peer student. Because there is a possibility of mutual discourse on the tutoring group that consist of similar grades.

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

Just noticeable difference of autocorrelation function (ACF) parameters of refrigerator noise (냉장고 소음 ACF 요소의 최소인지한계량 조사)

  • You, Jin;Jeong, Choong-Il;Jeon, Jin-Yong;Cho, Moon-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1442-1445
    • /
    • 2007
  • Just noticeable differences (jnds) of autocorrelation function (ACF) parameters - Phi (0), Tau 1 and Phi 1 - of household refrigerator noise were investigated by psychoacoustical analyses. Phi (0) of five refrigerators' noise was changed with equal (${\pm}$) interval level of 0.5-1.0 dB up to five intervals by manipulating sound pressure level of the noise. Tau 1 and Phi 1 were varied with equal (${\pm}$) interval of around 0.10 ms and 0.02, respectively. Pitch shifting and strengthen methods were applied for the Tau 1 and Phi 1 variations. As results of subjective evaluations, about 2.0 dB was shown as jnd of Phi (0). The values of 0.30 ms and 0.06 were found as jnds of Tau 1 and Phi 1, respectively. The jnd results of each ACF parameter can be applied to explain substantial amount of sound quality (SQ) enhancement in the SQ prediction indices which were proposed in the authors' previous study [Sato et al. (2007) J. Acoust. Soc. Am.].

  • PDF