A Study on Wearing Sensation in Accordance with difference in Materials of Aerobic Wear (에어로빅복의 소재 차이에 따른 착용감에 관한 연구)

  • 이미경;류숙희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.116-126
    • /
    • 1998
  • This study was conducted to examine the effect of difference in materials of aerobic wear on both human body's physiological reactions and subjective wearing sensation by comparing and analysing not only cotton sparidex A, B and C but nylon spandex D, E and F used as actually wearing materials. The rectal temperature of type A and I remained at high degree, the type C was higher from after high-speed running but dropped sharply when taking a break finally. Both skin temperature and mean skin temperature dropped sharply due to sweat occurred during physical exercise, and then rose slowly when taking a break. Type A -D and B-I showed that the mean skin temperature remained at high degree when wearing a cotton spandex. Type C's temperature within its aerobic wear was lower than type F while its relative humidity was higher than type F. Wearing sensation showed a change similar to wearing, particularly, which was remarkable in type B-E. Also, it was shown that humidity sensation, tactile sensation and comfort sensation were good when wearing the cotton spandex.

  • PDF

The Effects 12 Weeks of Combined Exercise Programs on Activities of Daily Living and Quality of Living Index in the Vascular Dementia Elders (12주간 복합운동프로그램이 혈관성 치매노인의 일상생활 수행능력과 삶의 질 지수에 미치는 효과)

  • Cho, Sung-Hyoun;Kim, Seung-Joon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.633-644
    • /
    • 2010
  • Purpose : This study was to investigate vascular dementia elders's activities of daily living, quality of life index and to determine how much vascular dementia elders is influenced by the 12 weeks combined exercise program with aerobic training and resistance exercise. Methods : Thirty patients with vascular dementia over 65 in B geriatrics hospital were recruited this study. Activities of daily living were measured by I-ADL(instrumental-activities of daily living) and B-ADL(basic-Activities of daily living) and quality of life index was measured by GQOL-D(geriatric quality of life scaledementia). Statistical analysis was used repeated one-way ANOVA to test mean difference by using SPSS 12.0 for windows. Results : After comparing the activities of daily living of experimental group that of control group according to the period of exercise, there were statistically significant differences in I-ADL, B-ADL score test and GQOL-D index test of both experimental and control groups. There was also a significant difference in comparing the results of 12 weeks exercise of the groups. Conclusion : 12 weeks combined exercise program had a good influence on vascular dementia elders's activities of daily living and quality of life index.

Vibration and Noise Analysis According to Blasting Method (발파공법에 따른 진동 및 소음 분석)

  • Kim, Min-Hyouck
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.150-151
    • /
    • 2022
  • Blasting is a method that uses explosives to crush the ground. This method is a highly efficient ground cleaning method that can secure high efficiency in a short time. However, explosions can damage local properties and produce high noise and vibration. Therefore, it is important to be careful because there are disadvantages such as the occurrence of many complaints from the surrounding area. In this paper measured and analyzed the noise and vibration generated during blasting at the blasting site in Korea. The noise and vibration generated during blasting were measured by ES03303.2b and ES03402.2a at a distance of 6 m, 12 m from the blasting point. As a result of the measurement, there was little difference between small and medium scale except for precision vibration blasting at a distance of 6m, but noise difference according to blasting scale was evident at a distance of 12m. As a result of the measurement, the maximum noise level was reduced to 5.5 dB(A) and the vibration level was reduced to 7.7 dB(V). In the future, the reliability of the test results can be further improved through additional tests, and it is judged that noise and vibration prediction models based on blasting methods, amount of charge, measuring distance, etc. can be developed.

  • PDF

Design Guideline of Waveguide-Below-Cutoff Array for Electromagnetic Pulse Shielding (EMP 차폐 도파관의 형상 결정 가이드라인 작성)

  • Pang, Seung-Ki;Kim, Jae-Hun;Yook, Jong-Gwan;Kim, Yuna;Kim, Sangin
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.86-91
    • /
    • 2016
  • Convenient design guideline for Waveguide-below-cutoff (WBC) array is proposed to obtain the minimum waveguide length for electromagnetic pulse (EMP) shielding. The analysis includes circular, rectangular, and hexagonal WBC, determine the total length of the waveguide. When the unit side of rectangular WBC and the diagonal line of hexagonal WBC are given as 30 mm, the length of hexagonal WBC is 5 mm shorter than rectangular case with shielding effectiveness (SE) 80 dB. The length difference is deepened with SE of 100 dB, which shows approximately 30 mm shorter length for hexagonal case than others. In addition, hexagonal WBC requires much shorter length than circular WBC. In conclusion, hexagonal case is the most effective with respect to flow velocity and pressure loss for equivalent SE.

A Synthesized Isotropic Pattern Antenna for Electromgnetic Environment Measurements (전자파환경 측정을 위한 합성 등방성 패턴 안테나)

  • 윤현보;최익권;임계재;백낙준;유희준
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 1992
  • A synthesized isotropic pattern antenna can be realized by arrangeing $\lambda$/ 2 dipole along each x, y, z axis. The sleeve type $\lambda$/ 2 dipole antenna is used as a basic element for a proper impedance matching at feeding point and minimum mutual coupling effect between each element at 820 MHz - 895 MHz band. The total electric field intensity radiated from the designed isotropic pattern antenna is drived from the magnetic vector potential which is produced by each sleeve $\lambda$/ 2 dipole in the far field. This total electric field intensity is inversely proportional only to distance $\gamma$from the origin of coordinates, and pattern factor variation is less than 2.1dB. The measured value of total electric field variation depending on pattern factor is less then 2.8dB, and the difference between the calculated and measured value is 0.7dB.

  • PDF

Optimization of a Broadband Waveguide Magic-T for X-Band Monopulse Tracking Radars (X-Band 모노펄스 추적 레이더를 위한 광대역 도파관 Magic-T 최적화 설계)

  • Hwang, Keum-Cheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1042-1049
    • /
    • 2009
  • Design and optimization of a broadband waveguide magic-T was performed for X-Band tracking radars. A multi-stepped conducting cylinder was used to enhance the bandwidth performance of the conventional waveguide magic-Ts. Particles swarm optimization in conjunction with genetic algorithm was employed to obtain the optimized geometrical parameters. The optimized design exhibits low reflection coefficient below -20 dB at all waveguide ports with frequency bandwidth of 12%. The transmission loss and difference are within 0.2 dB and 0.1 dB, respectively. Measured results are also shown to be in good agreement with the simulated results. Finally, the bandwidth performances for five and seven-stepped conducting cylinders are also investigated.

Rate-distortion based image segmentation using recursive merging (반복적 병합을 이용한 율왜곡 기반 영상 분할)

  • 전성철;임채환;김남철
    • Journal of Broadcast Engineering
    • /
    • v.4 no.1
    • /
    • pp.44-58
    • /
    • 1999
  • In this paper, a rate-distortion based image segmentation algorithm is presented using a recursive merging with region adjacency graph (RAG). In the method, the dissimilarity between a pair of adjacent regions is represented as a Lagrangian cost function considered in rate-distortion sense. Lagrangian multiplier is estimated in each merging step, a pair of adjacent regions whose cost is minimal is searched and then the pair of regions are merged into a new region. The merging step is recursively performed until some termination criterion is reached. The proposed method thus is suitable for region-based coding or segmented-based coding. Experiment results for 256x256 Lena show that segmented-based coding using the proposed method yields PSNR improvement of about 2.5 - 3.5 dB. 0.8 -1.0 dB. 0.3 -0.6 dB over mean-difference-based method. distortion-based method, and JPEG, respectively.

  • PDF

Performance Assessment of Speech Recogniger using Lombard Speech (롬바드 음성을 이용한 음성인식기의 성능 평가)

  • Jung, Sung-Yun;Chung, Hyun-Yeol;Kim, Kyung-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.59-68
    • /
    • 1994
  • This paper describes the performance assessment test and analysis of test results on a Korean speech recognizer which recognizes Lombard effect received speech in noisy environment, as a basic performance assessment research. In the assessement test, standard speech data were first manipulated close to speech uttered in a noisy environment, and then performance assessment tests were carried out along with the assessment items (the type of noise, SNR) in two ways-one with Lombard effect received speech(LES), the other with not received(NLES). As a result, when 90% of recognition rate is set to be a recognition limit, it was achieved at 10dB SNR point with LES, while at 30dB with NLES. This 20dB of SNR difference indicates Lombard effect should be considered in real world assessment test. The type of noises didn't affect performance of recognizers in out tests. ANOVA analysis, in evaluating several kinds of recognizers, showed every assessment item affecting the recognition performance could be quantified.

  • PDF

Noise Attenuation Effects of Trees (수목의 소음감쇄효과)

  • Kim, Seong-Il;Oh, Dong Ha
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.3
    • /
    • pp.400-409
    • /
    • 1994
  • To investigate the noise attenuation effects of various vegetation configurations, noise levels on 6 study sites along relatively heavy traffic roads were measured. The differences between noise level measures at 1m and 10m spots from the road range from 10 to 15dB depending upon the attributes of the vegetation. When flat grass land was set to control plot, the maximum noise attenuation at 10m spot was measured at the densely planted shrubs with 5dB difference. The areas on upward slope from the road showed the least attenuation effects. Based on the study results, an appropriate setting for low level residential area noise buffer belt would be densely planted shrubs with at least 3m width and 2m height. To be effective, 3m width soft areas covered with grasses are needed at the front and behind sides of the belt. More than 15dB of the noise level caused by the road traffic would be attenuated with the prescription.

  • PDF

The Under Water Ambient Noise at Voting-il Bay (영일만 부근에서의 수중소음)

  • HA Kang Lyeol;YOON Gab Dong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.3
    • /
    • pp.197-201
    • /
    • 1983
  • Underwater ambient noise level was measured at two points near the Youngil Bay. The environmental characteristics depend upon oceanographic conditions of sound propagation ana its implication on the source of ambient noise. Some noise sources were estimated, and the effect of the oceanographic conditions on the noise level variation had been considered. The results were as follows : 1) At the nearshore station of Youngil Bay, the ambient noise level in the near bottom(45m) was lower than that of the near surface(10m) by 15dB. This difference was due to spherical spreading from the upper to the lower layer. 2) At the open sea station which is located outside of the thermal front existing near the Youngil Bay, the ambient noise level of the upper layer(20m) was higher than that of the lower layer (100m) by $8{\sim}12dB$ below 50Hz and $15{\sim}23dB$ above 50Hz. 3) Above 60Hz the ambient noise level at the nearshore station was higher than that of the open sea station, while below 60Hz, the result was reverse. It appears that a boundary layer existed between the two stations.