• 제목/요약/키워드: cylindrical volume

검색결과 306건 처리시간 0.034초

생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구 (Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems)

  • 김윤기;고재균
    • 한국농공학회지
    • /
    • 제22권1호
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

심자도용 접선성분자장 측정방식 스퀴드 센서열 설계 (Design of a SQUID Sensor Array Measuring the Tangential Field Components in Magnetocardiogram)

  • 김기웅;이용호;권혁찬;김진목;김인선;박용기;이규원
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.56-63
    • /
    • 2004
  • We consider design factors for a SQUID sensor array to construct a 52-channel magnetocardiogram (MCG) system that can be used to measure tangential components of the cardiac magnetic fields. Nowadays, full-size multichannel MCG systems, which cover the whole signal area of a heart, are developed to improve the clinical analysis with high accuracy and to provide patients with comfort in the course of measurement. To design the full-size MCG system, we have to make a compromise between cost and performance. The cost is involved with the number of sensors, the number of the electronics, the size of a cooling dewar, the consumption of refrigerants for maintenance, and etc. The performance is the capability of covering the whole heart volume at once and of localizing current sources with a small error. In this study, we design the cost-effective arrangement of sensors for MCG by considering an adequate sensor interval and the confidence region of a tolerable localization error, which covers the heart. In order to fit the detector array on the cylindrical dewar economically, we removed the detectors that were located at the corners of the array square. Through simulations using the confidence region method, we verified that our design of the detector array was good enough to obtain whole information from the heart at a time. A result of the simulation also suggested that tangential-component MCG measurement could localize deeper current dipoles than normal-component MCG measurement with the same confidence volume; therefore, we conclude that measurement of the tangential component is more suitable to an MCG system than measurement of the normal component.

  • PDF

하이볼륨 플라이애시 콘크리트의 철근부식 저항성 및 임계 염화물량 (Resistance to Corrosion of Reinforcing Steel and Critical Chloride Content of High Volume Fly Ash Concrete)

  • 이현진;배수호;정상화
    • 한국건설순환자원학회논문집
    • /
    • 제5권4호
    • /
    • pp.375-381
    • /
    • 2017
  • 최근, 친환경 콘크리트에 대한 관심의 증가로, 플라이애시, 고로슬래그 미분말 및 실리카 퓸 등의 산업부산물을 혼입한 콘크리트의 사용이 증가되고 있다. 특히 이 같은 산업부산물은 콘크리트 내의 철근부식 저항성을 증가시키고 염화물이온 침투를 감소시키는 것으로 잘 알려져 있다. 이 실험연구의 목적은 시멘트량의 약 50%를 플라이애시로 치환한 하이볼륨 플라이애시 콘크리트(HVFAC)의 철근부식 저항성 및 임계 염화물량을 평가하는 것이다. 이를 위하여 철근 상부를 노출시킨 원주형 공시체의 철근부식 개시 시기를 추정하기 위하여 자연전위 측정에 의한 철근부식 모니터링을 수행하였다. 결론적으로, HVFAC의 철근부식 개시 시기는 플레인 콘크리트보다 1.2~1.3배 증가하여 철근부식 저항성이 우수한 것으로 나타났고, 플레인 콘크리트 및 HVFAC의 임계 염화물량은 각각 $0.80{\sim}1.20kg/m^3$, $0.89{\sim}1.60kg/m^3$으로 나타나, HVFAC가 플레인 콘크리트보다 1.1~1.3배 증가하는 것으로 나타났다.

방사선수술 시 다엽 콜리메이터를 기초로 한 IMAT의 선량분포 (Dosimetric Characteristics of Multileaf Collimator-based Intensity-modulated Arc Therapy for Stereotactic Radiosurgery)

  • 윤상모;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.93-97
    • /
    • 2007
  • 본 연구는 세기 변조된 multiple noncoplanar arc를 이용한 방사선수술 기법을 평가하기 위해 고안되었다. 정위적 방사선수술은 0.5 cm resolution의 MLC가 장착된 6-MV X-ray beam을 사용하였다. 본 연구에서는 단일 중심점(single isocenter)으로 5 gantry-couch 조합을 이용한 intensity modulated arc therapy (IMAT)를 응용하였다. 저자들은 2 cm의 구형 표적용적에 대하여 $25{\times}25cm$ 아크릴 팬톰으로 선량분포 특성을 조사하였다. 단일 중심점을 이용한 방사선조사에서 구형의 표적에 대하여 비교적 적절한 선량분포를 얻을 수 있음을 확인할 수 있었다. 80%의 선량 곡선이 frontal, saglttal, transverse planes에서 표적 용적을 적절히 포함하였으며, 40%와 80% 선량곡선 사이는 $4.0{\sim}4.5mm$이었다. 이것은 cylindrical cone을 이용한 다른 연구자들의 선량분포와 유사한 결과였다. 따라서, 본 연구에서 사용한 방사선수술 기법을 비정형적 모양의 뇌내 표적에 대한 방사선수술시에 이용이 가능할 것으로 사료된다.

  • PDF

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.

Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가 (The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery)

  • 김지현;손현수;이주영;박훈희
    • 핵의학기술
    • /
    • 제21권2호
    • /
    • pp.55-64
    • /
    • 2017
  • 최근 SPECT/CT의 보급과 함께 다양한 영상보정 방법들을 빠르고 정확하게 적용할 수 있게 되면서, 영상품질 향상과 더불어 정량적 정확성까지 기대할 수 있게 되었다. 그중 Collimator Detector Response (CDR) 회복(recovery)은 검출기면의 거리로부터 발생된 blurring 효과를 보상하여 분해능 회복을 목적으로 하는 보정방법이다. 본 연구에서는 SPECT/CT 영상에서 CDR recovery 가 적용되었을 때 검출거리 변화에 따른 정량적 변화를 알아보고자 하였다. 검출거리의 변화에 따른 획득 계수의 차이를 알아보고자 검출거리를 궤도방식(obit type)에 따라 Circular는 X, Y축 반경 30 cm, Non-Circular는 X, Y축 반경 21 cm, 10 cm, Non-Circular Auto(=Auto Body Contouring_ ABC, spacing limit 1 cm)로 설정하였고, 재구성 방법은 CDR recovery(CDRr)의 사용 유/무에 따른 계수 회복 차이를 알아보고자 OSEM (w/o CDRr)와 Astonish(3D-OSEM with CDRr)로 구분하여 적용하였다. 이 때 감쇠, 산란, 붕괴 보정은 모든 영상에 공통 적용하였다. 정량적 평가를 위해 교정인자(calibration factor_CF) 산출을 목적으로 교정영상(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, 물 9293 ml)을 획득하였고, 팬텀 실험을 위하여 50 cc 주사기에 물 31 ml를 채우고 $^{99m}TcO_4$ 123.3 MBq를 설정하여 팬텀영상을 획득하였다. 팬텀 영상에서 주사기 전체 체적에 VOI(volume of interest)를 설정하여 각 조건별로 총 계수 값을 측정하였고, CF를 적용시켜 설정된 참값 대비 추정값의 오차를 구하여 보정에 따른 정량적 정확성을 확인하였다. 산출된 CF는 154.27 (Bq/ml/cps/ml)이며, 각 조건별 영상에서 참값 대비 추정값은 OSEM에서 Circular 86.5%, Non-Circular 90.1%, ABC 91.3% Astonish에서 Circular 93.6%, Non-Circular 93.6%, ABC 93.9%으로 분석되었다. OSEM은 검출거리가 가까울수록 정확성이 높아졌으며, Astonish의 경우에는 거리와 상관없이 거의 유사한 값을 나타내었다. 오차는 OSEM Circular(-13.5%)에서 가장 크고, Astonish ABC(-6.1%)에서 가장 적었다. SPECT/CT영상에서 CDR recovery 적용을 통한 거리보상이 이루어 졌을 때 검출거리가 먼 조건에서도 근접검출과 거의 동일한 정량적 정확성을 보였고, 검출거리의 변화에 영향을 받지 않고 정확한 보정이 가능한 것을 확인 할 수 있었다.

  • PDF

법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향 (THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS)

  • 구봉주;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제31권6호
    • /
    • pp.452-459
    • /
    • 2006
  • 와동벽과 복합레진 수복물이 접착될 때, 복합레진의 치질에 대한 접착력과 레진 자체의 중합 시 발생하는 수축응력이 상충하게 된다. 이러한 수축응력의 크기는 와동의 형태요소 (C-factor)와 수복물의 체적에 영향을 받는다. 이에 본 실험에서는 단일 병 접착제를 사용한 복합레진 수복 시 법랑질 변연만으로 이루어진 와동의 C-factor와 체적이 미세누출에 미치는 영향을 미세 전류 측정법을 이용하여 정량적으로 분석하고 평가하였다. 연마기를 이용하여 40개의 건전한 우치 협면에 편평한 법랑질 표면을 형성하였다. 각각 10개의 치아에 원통형 와동을 형성하였으며, 와동의 깊이와 직경에 따라 4개 군으로 분류하였다 ( I군: 1.5 mm ${\times}$ 2.0 mm, II군: 1.5 mm ${\times}$ 6.0 mm, III군: 2.0 mm ${\times}$ 1.72 mm, IV군: 2.0 mm ${\times}$ 5.23 mm). 각기 와동의 C-factor는 4, 5.62, 2, 2.54를 보였다. 산 부식 후 단일 병 접착제인 BC Plus$^{TM}$ (Vericom, Korea)를 제조사의 지시에 따라 적용하고, 미세혼합형 복합레진인 Denfil$^{TM}$(Vericom)을 충전하였다. 40초씩 광중합 후 치아를 실온에서 증류수에 24시간 동안 보관한 다음, Sof-Lex system을 이용하여 연마하였고, 5$^{\circ}$C와 55$^{\circ}$C범위에서 500회 열순환을 시행하였다. 이후 미세전류 측정을 위해 치수강 내에 증류수를 채우고 치근단공을 통해 0.018 stainless wire를 삽입한 후 sticky wax로 근첨부를 밀봉하였으며, nail varnish를 수복물의 변연에서 1 mm를 제외한 전체 치면에 2회 도포하였다. 미세누출의 측정은 전기 화학적 방법을 이용하여 측정하였으며, 통계적 유의성은 95% 유의 수준의 Two-way ANOVA로 검증하여 , 다음과 같은 결과를 얻었다. 1. 복합레진 수복물의 체적이 적은 것이 큰 것에 비해 미세누출도가 적었으나, 통계학적으로 유의한 차이는 없었다. 2. 와동 형태와 연관된 C-factor는 복합레진 수복물의 미세누출도에 영향을 주지 않았다. 법랑질 변연을 갖는 와동에 단일 병 접착제를 사용한 본 실험에서는 복합레진의 중합 시 발생하는 수축응력에 영향을 미치는 것으로 알려진 수복물의 체적과 C-factor가 미세누출도에 영향을 주지 못하였다. 이는 법랑질과 접착시스템과의 강력한 접착력에 기인한 것으로 보이며, 앞으로 이에 대한 더 많은 연구가 필요할 것으로 사료된다.

원통 침지형 평막 생물반응기 내 산기량에 따른 3차원 유동현상에 관한 수치모사 (Numerical Simulation of Three Dimensional Fluid Flow Phenomena in Cylindrical Submerged Flat Membrane Bioreactor for Aeration Rate)

  • 김대천;정건용
    • 공업화학
    • /
    • 제25권4호
    • /
    • pp.401-408
    • /
    • 2014
  • 분리막 생물반응기에서 산기량 제어는 반응기 내 유체흐름과 특히 막표면 근방에서의 전단응력을 변화시켜 막오염 감소 및 에너지 절약을 구현하는 중요 독립변수 중 하나이다. 본 연구에서는 원통형 생물 반응기 중심에 침지형 평막을 장착하고 하부에서 공기가 공급되는 3차원적 시스템에 대하여 "COMSOL"프로그램을 사용하여 수치해석하였다. 용액의 점도, 온도는 일정하다고 가정했으며 투과액 부피와 산기량의 비인 $SAD_p$를 변수로 사용하였다. 유속센서, 동영상 이미지분석으로 측정한 유속과 수치해석 결과는 11% 이내에서 일치함을 확인하였다. 반응기 내 유체의 흐름은 산기관과 막모듈 구간에서 급격하게 증가하였으나 막모듈을 지나면서 감소하였으며 반응조 벽에서 중심축 방향으로 갈수록 유속이 증가하는 경향을 보였다. 막 표면에서 계산된 전단응력은 하단 중앙부가 가장 크게 나타났으며 산기량이 증가할수록 전단응력이 증가하였다. 특히 산기량을 0.15에서 0.25 L/min로 증가할 경우 크게 증가함을 확인할 수 있었다.

몸체 형상이 수중운동체의 공동 발달과 항력특성에 미치는 영향에 대한 수치적 연구 (A Numerical Study of Effects of Body Shape on Cavity and Drag of Underwater Vehicle)

  • 김형태;강경태;최정규;정영래;김민재
    • 대한조선학회논문집
    • /
    • 제55권3호
    • /
    • pp.252-264
    • /
    • 2018
  • The calculation of steady-state cavitating flows around Supercavitating Underwater Bodies (SUB's), which consist of a circular disk head (cavitator), a conical fore-body, a cylindrical middle-body and either a boat-tail or a flare-tail, are carried out. To calculate the axisymmetric cavitating flow, used is a commercial computational fluid dynamics code based on the finite volume method, Fluent. From the analysis of numerical results, the cavity and drag, affected by the fore-body and tail of the SUB's, are investigated. Firstly, the effect of the fore-body shape is investigated with the same disk cavitator and a cylindrical rear-body of fixed diameter. Then with the same cavitator and a fixed fore-body, the effect of the rear-body shape is investigated. Before the cavity generated by the cavitator covers the slant of fore-bodies sufficiently, the larger the cone angle of the fore-body(i.e., the shorter the slant length), the larger the drag and the slower the development of cavity. After the cavity covers the fore-body completely so that the pressure drag component of the body is vanished, the characteristics of drag-velocity curves are identical. Also, as the tail angle is bigger, the cavity generated by the cavitator is suppressed further and the drag becomes larger. The peak of the drag appears for the flare-tail, i.e., when the tail angle is positive(+). On the contrary, the trough of the drag appears for the boat-tail, i.e., when the tail angle is negative(-). When the tail angle is 5 degrees, the peak of the drag appears at the body speed of 80m/s and the value of the drag is 43% larger than that at the design speed of 100m/s. When the tail angle is -5 degrees, the trough of the total drag appears at 75m/s and that drag is 30% smaller than that of the cavitator, which means the rest of the body has a negative drag.

전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향 (Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer)

  • 곽정원;신정욱;김진성;박성용;신동호;윤명근;박소아;김동욱;임영경;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.291-297
    • /
    • 2010
  • 본 연구에서는 양성자 치료에서 치료부위에 금 마커를 삽입하였을 때 양성자 빔의 선량과 그 분포에 미치는 영향을 평가하였다. 1.2 mm 직경에 3 mm 길이의 원통형 금 마커가 사용되었고 양성자 빔의 여러 위치에서 각각의 선량에 미치는 영향을 조사하였다. 3차원 moving 팬텀과 유효 반경이 0.5 mm인 정위적 방사선 치료용 다이로드 검출기를 이용하여 금마커의 방사선 선량으로의 영향을 결정하였다. Gafchromic film을 이용한 필름에 의한 선량 평가도 시행하였다. 그리고 선량-체적관계 히스토그램을 통한 분석을 위하여 GEANT4 전산 모의 도구 모음을 이용한 전산모의를 실시하였다. 마커의 움직임에 대한 영향성을 평가하기 위하여 직장 풍선을 적용하고 금 마커를 삽입한 10명의 환자에 대한 MV 영상을 이용하였다. 하나의 금 마커에 의하여 처방선량의 95% 이하가 들어간 체적은 0.15 cc로 작지만 그 체적은 치료부위 안쪽에 위치하고 평행이동에 대하여 발려져서 없어지지 않았다. 금 마커의 위치와 양성자 빔의 상태에 따라서 선량분포에 각각 다른 영향을 미치고 이는 임상치료에서 충분히 고려되어야 할 것으로 사료된다.