• 제목/요약/키워드: cyclic flexural load

검색결과 113건 처리시간 0.027초

기계적 정착된 전단보강근을 가진 RC 기둥의 구조적 거동 (Structural Behavior of RC Columns with Mechanically Anchored Crossties under Cyclic Loading)

  • 이성호;천성철;오보환;나환선;김상구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.59-62
    • /
    • 2005
  • Seven columns laterally reinforced with either mechanically anchored crossties or conventional crossties under cyclic loading are tested. 4 columns are specimens for flexural strength and 3 columns are for shear strength. Main variable is anchorage types of crossties. Conventional hooks, 180$^{\circ}$ standard hook-mechanical anchorage and all mechanical anchorage type are used. The specimens are tested under 10$\%$ axial load of nominal axial capacity of the columns combined with increasing lateral load. From the flexure test, it is found that columns with mechanical anchorages exhibit superior performance in terms of ductility and energy dissipation. The crossties with mechanical anchorages reduce buckling length of longitudinal rebar. From the shear test, it is found that. 3 specimens exhibit almost the same strength, displacement, and shear failure mode at ductility factor =2.

  • PDF

반복하중을 받는 콘크리트충전 각형강관 보-기둥의 거동 (Behavior of Concrete-Filled Square Tubular Beam-Column under Cyclic Load)

  • 강창훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.387-395
    • /
    • 2000
  • 본 연구는 콘크리트충전 각형강관(CFT) 기둥의 강도와 변형능력의 평가 및 내진성능에 대한 기초 자료의 제시를 목적으로 한다. 실험체는 초고층 건물의 최하단기둥의 응력분포를 가정하여 켄틸레버형 기둥으로 하고, 총 18개의 실험체가 일정 축력과 반복 횡하중 하에서 실험되었다. 본 실험에 적용된 주요변수는 강관의 폭/두께 비, 세장비 (LO/D), 그리고 축력비이다. 각 변수가 기둥의 강도, 변형능력, 그리고 에너지 흡수능력에 미치는 영향이 기술되었고, 각국 규준식과 실험결과를 비교하였다. 분석결과, 피복형 한국강구조학회 규준은 합성 단면적과 탄성계수를 AIJ와 AISC-LRFD 수준으로 수정한다면, 충전형에도 적용가능 할 것으로 판단된다. 마지막으로, 구속효과를 고려하여 단면의 소성해석을 통하여 구한 B. Kato의 CFT 기둥의 휨내력 제안식은 실험결과와 좋은 대응을 나타내고 있다.

  • PDF

철근 콘크리트 벽과 강판 콘크리트 벽이 수직으로 만나는 이질접합 구조물의 면외 휨 거동 특성 연구 (A Study on Out-of-Plane Flexural Behavior of the Structure with a Vertical Plane Connection between a Reinforced Concrete Wall and a Steel Plate Concrete Wall)

  • 황경민;이경진;함경원;김원기
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.93-102
    • /
    • 2013
  • 본 연구에서는 철근콘크리트 벽과 강판 콘크리트 벽이 서로 수직면의 이질접합 형태로 만나는 벽의 면외 휨 거동 특성을 검토하기 위하여, L형 실험체를 제작하고 휨 실험을 수행하였다. 실험 시, 실험체의 동적특성을 확인하기 위하여 Push 및 Pull 하중을 반복하는 싸이클 하중을 구현하고자 하였다. Push 하중에 의한 실험 결과, 실험체의 공칭강도를 초과하는 휨 성능을 발휘하였으며, 이에 따라 설계에 적용된 수직철근의 미겹침 이음길이의 타당성을 확인할 수 있었다. 한편, Pull 하중 가력 시에는 수직철근이 최대 내력을 발휘하기 전에 접합부 콘크리트에서 전단 파괴 거동이 나타나, 이에 대한 보강이 필요함을 확인하였다.

피해가 발생된 휨벽체의 내진보강에 관한 연구 (Retrofit Method of Damaged Flexural Wall)

  • 서수연;이용택;이현호;이리형;천영수;양지수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.811-816
    • /
    • 2002
  • An experimental work is performed to evaluate the retrofit method of damaged flexural walls. For two flexural walls damaged up to almost failure, reinforcements yielded and concrete below height of 1d are replaced with new reinforcements and steel fiber concrete, respectively. In order to evaluate the effectiveness of Aramid sheet for retrofitting walls, Aramid sheet is also, attached to longitudinal direction and rolled horizontal direction of one wall specimen. Horizontal cyclic loads are applied to the top of the specimen with constant axial load. Test result showed that retrofitting with steel fiber concrete after replacing reinforcements can not afford to recover 100% of the wall capacity before damage. However, the capacity of walls could be sufficiently strengthened by using Aramid sheet.

  • PDF

강재 기둥과 하이브리드 강재 보-RC 보 접합부의 반복 휨 거동 평가 (Evaluation on Cyclic Flexural Behavior of HSRC (Hybrid H-steel-reinforced Concrete) Beams Connected with Steel Columns)

  • 권혁진;양근혁;홍승현
    • 콘크리트학회논문집
    • /
    • 제29권3호
    • /
    • pp.291-298
    • /
    • 2017
  • 이 연구에서는 강재 기둥과 접합된 하이브리드 H-보-철근 콘크리트 보(HSRC)의 반복 휨 거동을 평가하였다. 실험 변수는 HSRC 보의 연결절점에 배근되는 장부철근의 유무이다. HSRC 보의 소성힌지는 RC 보보다는 기둥 접합부 부근의 H-보에서 형성되도록 유도하였다. 모든 실험체는 하중의 급격한 감소 없이 연성적인 거동을 보였으며, 비록 예상치 못한 H-기둥과 H-보 용접 접합부의 파괴가 발생하였지만, 결과적으로 4.6 이상의 변위연성비를 나타내었다. HSRC 보 시스템에서 RC 보의 균열진전, 휨 강도 및 연성에 대한 장부철근의 영향은 매우 미미하였다. HSRC 보 시스템의 휨 강도는 단면의 완전소성으로 가정하여 산정한 H-보의 최대 휨 내력에 비해 안전 측에서 평가될 수 있었다.

CFRP를 이용한 비내진 철근콘크리트 외부 보-기둥 접합부의 내진 보강 (Seismic Retrofit of RC Exterior Beam-Column Joints Strengthened with CFRP)

  • 김민;이기학;이재홍;우성우;이정원
    • 콘크리트학회논문집
    • /
    • 제18권6호
    • /
    • pp.729-736
    • /
    • 2006
  • 적절한 내진상세로 설계되지 않은 철근콘크리트 구조물은 보-기둥 접합부내에서 취약한 전단파괴에 노출되고 큰 변형이 일어나, 구조적인 붕괴가 일어날 수 있다. 본 연구는 CFRP로 보강한 철근콘크리트 외부 보-기둥 접합부를 반복 횡력을 적용하여 보강된 보-기둥 접합부의 내진성능을 알아보았다. 보-기둥 접합부의 구조적 성능을 향상시키기 위해 CFRP의 부착 위치나 두께를 달리하여 효과적인 보강방법을 관찰하고자 하였다. 비내진상세로 배근된 실험체 1개와 내진상세로 배근된 실험체 1개 그리고 비내진상세를 가진 실험체를 CFRP로 보강한 실험체 6개, 총 8개의 보-기둥 접합부 실험체에 반복횡력을 가하여 내진보강의 효과를 조사하였다. 반복 횡력을 적용하였다. 본 연구에서는 비내진상세를 가진 콘크리트 보-기둥 접합부에 대한 CFRP의 보강방법은 구조물의 강도와 연성을 증가시켜 구조물의 내진성능을 향상시키는데 효과적임을 보여 주었다.

Seismic behavior of double steel plates and concrete filled composite shear walls subject to in-plane cyclic load: Experimental investigation

  • Xiaohu Li;Hao Luo;Xihao Ren;Tao Zhang;Lei Li;Ke Shi
    • Structural Engineering and Mechanics
    • /
    • 제90권4호
    • /
    • pp.345-356
    • /
    • 2024
  • This paper aims to investigate the seismic behavior of double steel plate and concrete composite shear wall (DSCW) of shield buildings in nuclear power engineering through experimental study. Hence, a total of 10 specimens were tested to investigate the hysteretic performance of DSCW specimens in detail, in terms of load vs. displacement hysteretic curves, skeleton curves, failure modes, flexural strength, energy dissipation capacity. The experimental results indicated that the thickness of steel plate, vertical load and stiffener have great influence on the shear bearing capacity of shear wall, and the stud space has limited influence on the shear capacity. And finally, a novel simplified formula was proposed to predict the shear bearing capacity of composite shear wall. The predicted results showed satisfactory agreement with the experimental results.

고성능 강섬유보강 콘크리트가 적용된 반복하중을 받는 이중 프리스트레스 콘크리트 보의 휨 거동 (Flexural Behavior of Dual Prestress Concrete Beams Using High Performance Steel Fiber Reinforced Concrete Subjected to Cyclic Loading)

  • 박대효;윤성환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.61-64
    • /
    • 2004
  • This study presents results from an experimental work for two normal prestressed concrete beams and three dual prestressed concrete beams. The dual prestressed concrete beams made with normal concrete in compression zone and high performance steel fiber reinforced concrete in partial depth of tension zone. Through cyclic loading test under low frequency, structural behavior and resistance to dynamic loading for dual prestressed concrete beams are investigated. Considerable increase of crack and yield load capacity of Dual prestressed concrete beam is shown compared with normal prestressed concrete beam. In addition, re-loading and un-loading rigidity of dual prestressed concrete beam under cyclic loading are increased comparing with normal prestressed concrete beam.

  • PDF

부분적인 비 부착 철근을 갖는 슬래브-기둥 접합부의 반복 횡하중 실험 (Tests of Slab-Column Connections with Partially Debonded Reinforcement under Cyclic Lateral Loading)

  • 최정욱;송진규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.13-16
    • /
    • 2006
  • This article summarizes tests conducted on two full-scale interior slab-column connections with and without partially debonded reinforcement subjected to cyclic loading. Each test specimen consisted of a 4.2m square slab with a 355mm square column protruding 1.5m above and below the slab. The slab thickness was 152mm. The specimen with partially debonded reinforcement exhibited more lateral drift capacity than did the specimen with fully bonded reinforcement. With partial debonding of the flexural reinforcement, cyclic load appeared to produce less damage to the connection in the vicinity of the slab-column joint region.

  • PDF

Flexural behavior of retrofitted RC columns by FRP-MF, Experimental approach

  • Mahdavi, Navideh;Tasnimi, Abbas Ali
    • Steel and Composite Structures
    • /
    • 제33권3호
    • /
    • pp.347-356
    • /
    • 2019
  • Most of the recent studies have improved the efficiency of FRP jackets for increasing the compressive strength, shear strength, and ductility of reinforced concrete columns; however, the influence of FRP jackets on the flexural capacity is slight. Although new methods such as NSM (near surface mounted) are utilized to solve this problem, yet practical difficulties, behavior dependency on adhesives, and brittle failure necessitate finding better methods. This paper presents the results of an experimental study on the application of fiber-reinforced polymer fastened mechanically to the concrete columns to improve the flexural capacity of RC columns. For this purpose, mechanical fasteners were used to achieve the composite behavior of FRP and concrete columns. The experimental program included five reinforced concrete columns retrofitted by different methods using FRP subjected to constant axial compression and lateral cyclic loading. The experimental results showed that the use of the new method proposed in this paper increased the flexural strength and lateral load capacity of the columns significantly, and good composite action of FRP and RC column was achieved. Moreover, the experimental results were compared with the results obtained from the analytical study based on strain compatibility, and good proximity was reached.