• Title/Summary/Keyword: cycle count

Search Result 134, Processing Time 0.028 seconds

New High Performance and Low Cost Construction of Unified Power System for LCD TV Backlight Driver Circuitb (LCD TV를 위한 새로운 구조의 고성능 및 저가형 Backlight 구동 전원 통합 시스템)

  • Jang, Doo-Hee;Lee, Jae-Kwang;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Jin-Wook;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A new high performance and low cost unified power system is proposed through investigating conventional Power-Integrated Drive(PID) system and Power-Separated Drive(PSD) system applied to LCD TV. Since the proposed system consists of two stage, namely power and inverter stage it features high efficiency and cost effectiveness. To satisfy the safety standard of the High voltage transformer, 1:1 transformer is employed between inverter and high voltage transformer. Moreover, to ensure the Zero Voltage Switching(ZVS) of all power switches and the Pulse Count Modulation(PCM) method is employed, which controls the number of pulse at the fixed frequency and fixed duty cycle. Therefore, it features high efficiency, improved heat generation, cost effectiveness and good EMI performance including no additional current balancing coil. To confirm the validity of proposed system, comparison of conventional system, verification of experimental results are presented.

A Study on the Optimal Position for the Secondary Neutron Source in Pressurized Water Reactors

  • Sun, Jungwon;Yahya, Mohd-Syukri;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1291-1302
    • /
    • 2016
  • This paper presents a new and efficient scheme to determine the optimal neutron source position in a model near-equilibrium pressurized water reactor, which is based on the OPR1000 Hanul Unit 3 Cycle 7 configuration. The proposed scheme particularly assigns importance of source positions according to the local adjoint flux distribution. In this research, detailed pin-by-pin reactor adjoint fluxes are determined by using the Monte Carlo KENO-VI code from solutions of the reactor homogeneous critical adjoint transport equations. The adjoint fluxes at each allowable source position are subsequently ranked to yield four candidate positions with the four highest adjoint fluxes. The study next simulates ex-core detector responses using the Monte Carlo MAVRIC code by assuming a neutron source is installed in one of the four candidate positions. The calculation is repeated for all positions. These detector responses are later converted into an inverse count rate ratio curve for each candidate source position. The study confirms that the optimal source position is the one with very high adjoint fluxes and detector responses, which is interestingly the original source position in the OPR1000 core, as it yields an inverse count rate ratio curve closest to the traditional 1/M line. The current work also clearly demonstrates that the proposed adjoint flux-based approach can be used to efficiently determine the optimal geometry for a neutron source and a detector in a modern pressurized water reactor core.

Does bilateral uterine artery ligation have negative effects on ovarian reserve markers and ovarian artery blood flow in women with postpartum hemorrhage?

  • Verit, Fatma Ferda;Cetin, Orkun;Keskin, Seda;Akyol, Hurkan;Zebitay, Ali Galip
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.46 no.1
    • /
    • pp.30-35
    • /
    • 2019
  • Objective: Bilateral uterine artery ligation (UAL) is a fertility-preserving procedure used in women experiencing postpartum hemorrhage (PPH). However, the long-term effects of this procedure on ovarian function remain unclear. The aim of this study was to investigate whether bilateral UAL compromised ovarian reserve and ovarian blood supply. Methods: This prospective study included 49 women aged between 21 and 36 years who had undergone a cesarean section for obstetric indications. Of these, 25 underwent uterine bilateral UAL to control intractable atonic PPH. The control group consisted of 24 women who had not undergone bilateral UAL. Standard clinical parameters, the results of color Doppler screening, and ovarian reserve markers were assessed in all participants at 6 months after surgery. The clinical parameters included age, parity, cycle history, body mass index, and previous medication and/or surgery. Color Doppler screening findings included the pulsatility index (PI) and resistance index (RI) for both the uterine and ovarian arteries. The ovarian reserve markers included day 3 follicle-stimulating hormone (FSH) levels, antral follicle count, and $anti-M\ddot{u}llerian$ hormone (AMH) levels. Results: There were no significant differences in the ovarian reserve markers of day 3 FSH levels, antral follicle count, and AMH levels between the study and control groups (p> 0.05 for all). In addition, no significant differences were observed in the PI and RI indices of the uterine and ovarian arteries (p> 0.05 for all). Conclusion: In this study, we showed that bilateral UAL had no negative effects on ovarian reserve or ovarian blood supply, so this treatment should be used as a fertility preservation technique to avoid hysterectomy in patients experiencing PPH.

Novel nomogram-based integrated gonadotropin therapy individualization in in vitro fertilization/intracytoplasmic sperm injection: A modeling approach

  • Ebid, Abdel Hameed IM;Motaleb, Sara M Abdel;Mostafa, Mahmoud I;Soliman, Mahmoud MA
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.48 no.2
    • /
    • pp.163-173
    • /
    • 2021
  • Objective: This study aimed to characterize a validated model for predicting oocyte retrieval in controlled ovarian stimulation (COS) and to construct model-based nomograms for assistance in clinical decision-making regarding the gonadotropin protocol and dose. Methods: This observational, retrospective, cohort study included 636 women with primary unexplained infertility and a normal menstrual cycle who were attempting assisted reproductive therapy for the first time. The enrolled women were split into an index group (n=497) for model building and a validation group (n=139). The primary outcome was absolute oocyte count. The dose-response relationship was tested using modified Poisson, negative binomial, hybrid Poisson-Emax, and linear models. The validation group was similarly analyzed, and its results were compared to that of the index group. Results: The Poisson model with the log-link function demonstrated superior predictive performance and precision (Akaike information criterion, 2,704; λ=8.27; relative standard error (λ)=2.02%). The covariate analysis included women's age (p<0.001), antral follicle count (p<0.001), basal follicle-stimulating hormone level (p<0.001), gonadotropin dose (p=0.042), and protocol type (p=0.002 and p<0.001 for short and antagonist protocols, respectively). The estimates from 500 bootstrap samples were close to those of the original model. The validation group showed model assessment metrics comparable to the index model. Based on the fitted model, a static nomogram was built to improve visualization. In addition, a dynamic electronic tool was created for convenience of use. Conclusion: Based on our validated model, nomograms were constructed to help clinicians individualize the stimulation protocol and gonadotropin doses in COS cycles.

Quality and fermentative characteristics of yogurt added with hot water extract of Welsh onion root (파뿌리 열수추출물을 이용한 요구르트의 발효 및 품질특성)

  • Kim, Min-Jeong;Lee, Shin-Ho
    • Food Science and Preservation
    • /
    • v.24 no.3
    • /
    • pp.387-393
    • /
    • 2017
  • The objective of this study was to investigate the effect of hot water extract of Welsh onion root (HEWO) on growth of lactic acid bacteria and fermentative characteristics of yogurt. The physiochemical characteristics of HEWO such as pH, soluble solid, reducing sugar, total polyphenol content and DPPH radical scavenging activity were studied. The lactic bacterial count in brain heart infusion (BHI) broth with HEWO was about 1 log cycle higher than in control for 24 h at $37^{\circ}C$. The pH of yogurt prepared with HEWO (WY100) and 50% HEWO (WY50) was gradually decreased significantly but increased the viscosity of yogurt with increasing HEWO concentration during fermentation. The viable cells of lactic acid bacteria after fermentation for 24 h were 8.03 (control), 8.77 (WY50), 8.84 (WY100) log CFU/mL, respectively. The DPPH radical scavenging activity of yogurt increased with increasing HEWO concentration. Sensory quality of yogurt prepared with HEWO was higher than that of control. The pH and lactic acid bacteria of all tested yogurts decreased during storage for 10 days at $4^{\circ}C$ but lactic bacterial count of yogurt prepared with HEWO maintained $10^8CFU/mL$ during storage. These results indicated the potential use of HEWO as a valuable resource to improve fermentation and functionality of yogurt.

A STUDY ON THE SANITARY QUALITY OF PACIFIC OYSTERS, CRASSOSTREA GIGAS AND GROWING WATERS IN BURLEY LAGOON, WASHINGTON (미국 Washington주 Burley Lagoon에 있어서의 참굴, Crassostrea gigas과 그 서식수역에 대한 위생학적 연구)

  • KIM Seonh Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.7 no.2
    • /
    • pp.41-51
    • /
    • 1974
  • A study of the sanitary quality of Pacific oysters (Crassostrea gigas) and growing waters associated with raft culture in Burley Lagoon, Washington was conducted. The study was sponsored by the Agency for International Development of the U.S. Department of State. The results obtained in this study are as follows: The average values of temperature, salinity and turbidity in the water showed that the values of bottom sample were slightly higher than top samples. The difference was about $0.3^{\circ}C$ for temperature, $0.5\%_{\circ}$ for salinity and 0.1 JTU for turbidity. The changes of temperature and salinity by tide generally followed the tide cycle pattern. Sanitary indicator microorganism concentrations in top water were generally higher than those in bottom water. In general, the levels of mean coliform and fecal coliform MPN's varied inversely with tide level indicating that the sources of these groups of microorganisms are the fresh water streams flowing into the estuary. The $35^{\circ}C$ plate counts were more stable at different tide levels. Mean values of coliform and fecal coliform MPN's in oysters demonstrated that levels in top oysters were generally higher than those in bottom oysters. However, mean values of $35^{\circ}C$ Plate count in oysters did not show this pattern. The mean levels of both coliform and fecal coliform MPN's in oysters also correlated inversely with tidal level. The accumulation ratios of oysters obtained during the study period ranged from 8.6 to 19.7 for mean coliform MPN and 16.9 to 44.3 for fecal coliform MPN. According to the results obtained from present study, one suggestion could be of considerable importance for the sanitary operation in hanging culture of pacific oysters. The results indicate that harvest of the oysters at high tide would result in lower levels of indicator organisms in the shellfish.

  • PDF

Utility Analysis for Pegfilgrastim in DLBCL Patients on R-CHOP Regimen (항암치료를 받는 미만성거대비세포 림프종 환자에서 페그필그라스팀에 대한 효용성 평가)

  • Jung, Hee Won;Kim, Jeong Mee;Min, Myung Sook;Lee, Young Mee;Bang, Joon Seok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.25 no.3
    • /
    • pp.151-158
    • /
    • 2015
  • Objective: This study was designed to compare pegfilgrastim and filgrastim in diffuse large B-cell lymphoma (DLBCL) patients treated with a rituximab with cyclophosphamide, hydroxydaunorubicin, oncovin, and prednisone (R-CHOP) regimen in terms of clinical efficacy and cost-effectiveness. Method: Clinical efficacy was measured by trough level of absolute neutrophil count (ANC), days of ANC under 50% of baseline value, days of ANC under 90% of baseline value, duration of ANC recovery to baseline value, days of ANC less than $0.5{\times}10^9cells/L$, and difference of peak and trough level of ANC during 1 cycle of R-CHOP regimen. To evaluate cost-effectiveness, total prices of used filgrastim and pegfilgrastim within 1 cycle of R-CHOP were analyzed. Results: In terms of clinical efficacy, trough level of ANC and days to ANC recovery showed statistical significance. The median trough levels of ANC with administration of filgrastim and pegfilgrastim were 0.18 and 1.94 (p = 0.021), respectively, and the median durations of ANC recovery to baseline value were 5.5 days and 2 days (p = 0.023), respectively. For the median days of ANC under 50% of baseline value, days of ANC under 90% of baseline value, days of ANC less than $0.5{\times}10^9cells/L$, and difference of peak and trough level of ANC during 1 cycle of R-CHOP, the pegfilgrastim group performed better than the filgrastim group. However the difference was not statistically significant. In terms of overall expense during 1 cycle of R-CHOP, pegfilgrastim is about 3.43 times more expensive than filgrastim. Conclusion: Pegfilgrastim is more efficient than filgrastim in terms of clinical efficacy. In terms of prices, pegfilgrastim is more expensive than filgrastim for patients, but it is more convenient in clinical use. Therefore, pegfilgrastim should be the preferred choice of G-CSF for neutropenic patients. Further comparative study of pegfilgrastim and filgrastim is needed.

A VLSI Design of High Performance H.264 CAVLC Decoder Using Pipeline Stage Optimization (파이프라인 최적화를 통한 고성능 H.264 CAVLC 복호기의 VLSI 설계)

  • Lee, Byung-Yup;Ryoo, Kwang-Ki
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.12
    • /
    • pp.50-57
    • /
    • 2009
  • This paper proposes a VLSI architecture of CAVLC hardware decoder which is a tool eliminating statistical redundancy in H.264/AVC video compression. The previous CAVLC hardware decoder used four stages to decode five code symbols. The previous CAVLC hardware architectures decreased decoding performance because there was an unnecessary idle cycle in between state transitions. Likewise, the computation of valid bit length includes an unnecessary idle cycle. This paper proposes hardware architecture to eliminate the idle cycle efficiently. Two methods are applied to the architecture. One is a method which eliminates an unnecessary things of buffers storing decoded codes and then makes efficient pipeline architecture. The other one is a shifter control to simplify operations and controls in the process of calculating valid bit length. The experimental result shows that the proposed architecture needs only 89 cycle in average for one macroblock decoding. This architecture improves the performance by about 29% than previous designs. The synthesis result shows that the design achieves the maximum operating frequency at 140Mhz and the hardware cost is about 11.5K under a 0.18um CMOS process. Comparing with the previous design, it can achieve low-power operation because this design is implemented with high throughputs and low gate count.

Inactivation of Microorganisms and Enzymes in Foxtail Millet Yakju by High Hydrostatic Pressure Treatment (초고압 처리에 의한 좁쌀약주의 미생물 살균 및 효소 불활성화)

  • 좌미경;임상빈;목철균;박영서
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.8
    • /
    • pp.1221-1226
    • /
    • 2003
  • High hydrostatic Pressure was applied to Foxtail Millet Yakju to investigate the effects of high pressure on inactivation of microorganisms and enzymes. Total bacteria, lactic acid bacteria and yeast in untreated Yakju were $1.5{\times}$10$^4$,1.9${\times}$10$^4$ and 1.4${\times}$10$^4$ CFU/mL, respectively. Total bacterial count was reduced to 4.1${\times}$l0$^2$ CFU/mL, while lactic acid bacteria and yeast were sterilized completely in Yakju heated at $65^{\circ}C$ for 15 min. Lactic acid bacteria and yeast decreased greatly with the increase of treatment pressure, and were sterilized completely in Yakju treated at more than 300 ㎫ for 10 min/$25^{\circ}C$. Total bacteria were not completely sterilized with pressurization of even 600 ㎫ at room temperature and reduced to 2 log cycle even at $65^{\circ}C$. Total bacteria decreased by 2∼3 log cycle with the increase of treatment time from 10 to 60 min at $25^{\circ}C$/300 ㎫. Pressurization of Yakju caused a partial inactivation of $\alpha$ -amylase and glucosamylase, and the activities of $\alpha$ -amylase and glucoamylase decreased by 18.1% and 21.1%, respectively at $25^{\circ}C$/600 ㎫/10 min. Activities of $\alpha$ -amylase and glucoamylase decreased with the increase of temperature, and 22.2% and 32.1% of the original activity were remained with the treatment at $65^{\circ}C$/300 ㎫/10 min, respectively. Enzyme activities decreased slightly with the increase of treatment time at $65^{\circ}C$/300 ㎫.

A 4-parallel Scheduling Architecture for High-performance H.264/AVC Deblocking Filter (고성능 H.264/AVC 디블로킹 필터를 위한 4-병렬 스케줄링 아키텍처)

  • Ko, Byung-Soo;Kong, Jin-Hyeung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.8
    • /
    • pp.63-72
    • /
    • 2012
  • In this paper, we proposed a parallel architecture of line & block edge filter for high-performance H.264/AVC deblocking filter for Quad Full High Definition(Quad FHD) video real time processing. To improve throughput, we designed 4-parallel block edge filter with 16 line edge filter. To reduce internal buffer size and processing cycle, we scheduled 4-parallel zig-zag scan order as deblocking filtering order. To avoid data conflicts we placed 1 delay cycle between block edge filtering. We implemented interleaving buffer, as internal buffer of block edge filter, to sharing buffer for reducing buffer size. The proposed architecture was simulated in 0.18um standard cell library. The maximum operation frequency is 108MHz. The gate count is 140.16Kgates. The proposed H.264/AVC deblocking filter can support Quad FHD at 113.17 frames per second by running at 90MHz.