• Title/Summary/Keyword: cyber cube

Search Result 9, Processing Time 0.03 seconds

Efficient Formulas for Cube roots in $F_{3^m}$ for Pairing Cryptography (페어링 암호 연산을 위한 $F_{3^m}$에서의 효율적인 세제곱근 연산 방법)

  • Cho, Young-In;Chang, Nam-Su;Kim, Chang-Han;Park, Young-Ho;Hong, Seok-Hie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.2
    • /
    • pp.3-11
    • /
    • 2011
  • Evaluation of cube roots in characteristic three finite fields is required for Tate (or modified Tate) pairing computation. The Hamming weights (the number of nonzero coefficients) in the polynomial representations of $x^{1/3}$ and $x^{2/3}$ determine the efficiency of cube roots computation, where $F_{3^m}$is represented as $F_3[x]/(f)$ and $f(x)=x^m+ax^k+b{\in}F_3[x]$ (a, $b{\in}F_3$) is an irreducible trinomial. O. Ahmadi et al. determined the Hamming weights of $x^{1/3}$ and $x^{2/3}$ for all irreducible trinomials. In this paper, we present formulas for cube roots in $F_{3^m}$ using the shifted polynomial basis(SPB). Moreover, we provide the suitable shifted polynomial basis bring no further modular reduction process.

A Motion Control utilizing Human Motions (사람의 움직임을 쓴 운동 제어)

  • 최원수;손호영;윤중선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.243-247
    • /
    • 1996
  • A general procedure for motion capture and mimic system has been delineated. Utilizing sensors operated in the magnetic fields, complicated and optimized movements are easily digitized to analyze and reproduce. The system consists of a motion capture module, a motion visualization module, a motion plan module, a motion mimic module, and a GUI module. Design concepts of the system are modular, open, and user friendly to ensure the overall system performance. This procedure is being implemented on a virtual cyber cube. and an inverted pendulum. With modifications, this procedure can applied for complicated motion controls.

  • PDF

A motion capture and mimic system (운동포착 및 재현 시스템)

  • 윤중선;최원수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1344-1347
    • /
    • 1996
  • A general procedure for motion capture and mimic system has been delineated. Utilizing sensors operated in the magnetic fields, complex and optimized movements are easily digitized to analyze and follow. Design concepts of the system are modular, open, and user friendly to ensure the overall system performance. The system consists of motion capture, visualization, plan, mimic and GUI modules. This procedure is currently being implemented on a virtual cyber cube.

  • PDF

Requirement Analysis and Conceptual Design for a Cybrid Virtual Plant System (Cybrid 가상플랜트 시스템 요구사항 분석과 개념적 설계)

  • Lee, Jae Hyun;Suh, Hyo Won
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.4
    • /
    • pp.401-411
    • /
    • 2015
  • Cybrid virtual plant concept is defined as a cyber plant mimicking a physical plant by using plant engineering data and sensor data coming from sensors attached to facilities of the physical plant. Cybrid virtual plant is a new concept for plant industry so that plant managers and operators' requirements need to be captured for systematic application of the concept to the plant industry. The paper proposed an architecture of the cybrid virtual plant, and provided requirement analysis results for a specific plant company. A database, named smart-cube repository, for the proposed cybrid virtual plant is also proposed and its conceptual data structure is described.

Accuracy Evaluation of CyberKnife $Synchrony^{TM}$ Respiratory Tracking System Using Phantom (Phantom을 이용한 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Lim, Chang-Seon;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.137-143
    • /
    • 2009
  • This study was conducted to evaluate the accuracy of CyberKnife $Synchrony^{TM}$ respiratory tracking system which was applied to Stereotactic Radiosurgery (SRS) for moving tumors in chest and abdomen with breathing motion. For accurate evaluation, gold fiducial marks were implanted into a moving phantom. The moving phantom was a cube imbedding an acryl ball as a target. The acryl ball was prescribed to 20 Gy at 70% of isodose curve in a virtual treatment and radiochromic films were inserted into the acryl ball for dose verification and tracking accuracy evaluation. The evaluation of position tracking consists of two parts: fiducial mark tracking in a stationary phantom and $Synchrony^{TM}$ respiratory tracking in a moving phantom. Each measurement was done in three directions and was repeated to 5 times. Range of position error was 0.1957 mm to 0.6520 mm in the stationary phantom and 0.4405 mm to 0.7665 mm in the moving phantom. Average position error was 0.3926 mm and 0.5673 mm in the stationary phantom and the moving phantom respectively. This study evaluates the accuracy of CyberKnife $Synchrony^{TM}$ Respiratory tracking system, and confirms the usefulness when it's used for Stereotactic Radiosurgery of body organs.

Faster MapToPoint over $F_{3^m}$ for Pairing-based Cryptosystems (페어링 암호 시스템을 위한 $F_{3^m}$에서의 효율적인 MapToPoint 방법)

  • Park, Young-Ho;Cho, Young-In;Chang, Nam-Su
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.6
    • /
    • pp.3-12
    • /
    • 2011
  • A hashing function that maps arbitrary messages directly onto curve points (MapToPoint) has non-negligible complexity in pairing-based cryptosystems. Unlike elliptic curve cryptosystems, pairing-based cryptosystems require the hashing function in ternary fields. Barreto et al. observed that it is more advantageous to hash the message to an ordinate instead of an abscissa. So, they significantly improved the hashing function by using a matrix with coefficients of the abscissa. In this paper, we improve the method of Barreto et al. by reducing the matrix. Our method requires only 44% memory of the previous result. Moreover we can hash a message onto a curve point 2~3 times faster than Barreto's Method.

A New Cryptographic Algorithm for Safe Route Transversal of Data in Smart Cities using Rubik Cube

  • Chhabra, Arpit;Singhal, Niraj;Bansal, Manav;Rizvi, Syed Vilayat
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.8
    • /
    • pp.113-122
    • /
    • 2022
  • At the point when it is check out ourselves, it might track down various information in each turn or part of our lives. Truth be told, information is the new main thrust of our advanced civilization and in this every day, "information-driven" world, security is the significant angle to consider to guarantee dependability and accessibility of our organization frameworks. This paper includes a new cryptographic algorithm for safe route traversal for data of smart cities which is a contemporary, non-hash, non-straight, 3D encryption execution intended for having information securely scrambled in the interim having a subsequent theoretical layer of safety over it. Encryption generally takes an information string and creates encryption keys, which is the way to unscramble as well. In the interim in another strategy, on the off chance that one can sort out the encryption key, there are opportunities to unravel the information scrambled inside the information string. Be that as it may, in this encryption framework, the work over an encryption key (which is created naturally, henceforth no pre-assurance or uncertainty) just as the calculation produces a "state" in a way where characters are directed into the Rubik block design to disregard the information organization.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.