• Title/Summary/Keyword: cut-off temperature

Search Result 140, Processing Time 0.026 seconds

Enzyme Deactivation During Enzyme Recycling with Ultrafiltration Hollow Fibers (한외여과막을 이용한 효소재순환 시스템에서의 효소역가감소)

  • 김준석;정용섭홍석인
    • KSBB Journal
    • /
    • v.11 no.3
    • /
    • pp.347-352
    • /
    • 1996
  • The enzyme deactivation in a membrane recycling system for the simultaneous saccharification and fermentation(SSF) was studied under various temperature and pressure. The optimum molecular weight cut off(MWCO) of the ultrafiltration membrane for recycling cellulase and ${\beta}$-glucosidase was 50,000. When the cellulase was recycled continuously through the membrane system, it was not deactivated. But the activity of ${\beta}$-glucosidase was decreased with an increase in operating temperature and transmembrane pressure. After 720 minutes at $42^{\circ}C$ and 24.8 psig , the activity of ${\beta}$-glucosidase was reduced by 35% of the initial activity. Such tendencies could be well explained by the results of highly induced shear at the fiber surface of membrane when temperature and transmembrane pressure became higher.

  • PDF

A Numerical Study for Performance of Automotive HVAC System (전산해석에 의한 자동차용 HVAC 시스템의 성능 연구)

  • Lee Dae-Woong;Yoo Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1084-1091
    • /
    • 2004
  • In automotive air handling system, mixing of air streams by the cooler and the heater affects the comfort of cabin room. In the present study, computer-aided analysis is done to improve the thermal comfort and for the optimal design of automotive HVAC system. The simulation software used was FLUENT, and complicate geometries were created by three dimensional CAD. Air flow volume, fir distribution rate and temperature controllability and temperature differences between upper and lower discharge air are analyzed through numerical simulation at vent, floor and defrost mode. Also, velocity vector of sirocco fan is investigated through the scroll housing. The velocity vector magnitude is larger at lower region of fan than that at any other regions. Recirculation and disturbance of air is relatively high near the cut-off edge in the scroll housing. By using the results of this study, the time for prototype production can be reduced and timely decisions can be made to determine initial design directions.

Effects of Fouling on Permeate Flux during Ultrafiltration of Protein Solutions in a Hollow-Fiber Membrane Reactor (중공사 막반응기에서 단백질용액의 한외여과시 유출속도에 미치는 Fouling의 영향)

  • 김세권;변희국이환근하진환
    • KSBB Journal
    • /
    • v.9 no.5
    • /
    • pp.483-491
    • /
    • 1994
  • It is known that a key limiting factor to the use of ultrafiltration membranes is that of membrane fouling, which has been a major cause of permeate flux reduction. In this work, the effects of several factors (operating time, protein concentration, temperature and pH, etc.) influencing permeate flux during ultrafiltration of gelatin, casein and bovine serum albumin using a hollow fiber membrane(M. W. 10,000 cut off) reactor have been examined. The permeate flux of gelatin solution was maintained almost constant during the operation up to 6 hours, but those of casein and albumin solutions were decreased to 50% and 43% of initial value after an operation time of 60min. The permeate flux with increasing concentration and temperature of protein solutions increased, but the permeate flux showed a minimum value near the isoelectric point of proteins. The permeate fluxes of protein solution were enhanced by a temperature increase and pH control. Also, it is proposed that fouling can be decreased by the pretreatment of insoluble proteins with enzymes.

  • PDF

Evaluation of temperature effects on brake wear particles using clustered heatmaps

  • Shin, Jihoon;Yim, Inhyeok;Kwon, Soon-Bark;Park, Sechan;Kim, Min-soo;Cha, YoonKyung
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.680-689
    • /
    • 2019
  • Temperature effects on the generation of brake wear particles from railway vehicles were generated, with a particular focus on the generation of ultrafine particles. A real scale brake dynamometer test was repeated five times under low and high initial temperatures of brake discs, respectively, to obtain generalized results. Size distributions and temporal patterns of wear particles were analyzed through visualization using clustered heatmaps. Our results indicate that high initial temperature conditions promote the generation of ultrafine particles. While particle concentration peaked within the range of fine sized particles under both low and high initial temperature, an additional peak occurred within the range of ultrafine sized particles only under high initial temperature. The timing of peak occurrence also differed between low and high initial temperature conditions. Under low initial temperature fine sized particles were generated intensively at the latter end of braking, whereas under high initial temperature both fine and ultrafine particles were generated more dispersedly along the braking period. The clustered correlation heatmap divided particle sizes into two groups, within which generation timing and concentration of particles were similar. The cut-off point between the two groups was approximately 100 nm, confirming that the governing mechanisms for the generation of fine particles and ultrafine particles are different.

A Study for Tubing Pipe Flaw Sizing by Using Guided Ultrasonic Wave (유도초음파기법을 이용한 튜빙 결함측정에 관한 연구)

  • Joo, Kyung Mun;Cheon, Keun Young;Lee, Jeong Seok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • There is extensive tubing pipe in the nuclear power plant under high temperature and pressure. Erosion and corrosion defects are expected on this tubing pipe due to environmental and mechanical factors. In this study, Guided Ultrasonic Wave technique was applied to detect defects. The technique explores the advantages of the Guided Ultrasonic Wave method that inspects along the wall of the pipe and can travel long distances, providing rapid collection of data. This paper presents a case study of the Guided Ultrasonic Wave testing of 3/8" tubing pipe. This study offers to understand detected signals through correlation between amplitude and depth of defects.

  • PDF

A Fabrication and Characteristics of GaInAs/InP PIN Phtodiode Grown by LPE (LPE에 의한 GaInAs/InP PIN Photodiode의 제작 및 특성)

  • 박찬용;남은수;박경현;김상배;박문수;이용탁;홍창희
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.737-746
    • /
    • 1990
  • Ga0.47In0.53As PIN photodiodes(PD) having various areas have been fabricated by liquid phase epitaxial techniques. Ternary melt has been baked out at 675\ulcorner in H2 atmosphere for 20 hours before growth, which resulted in reduction of background carrier concentration of grown epi-layer. Also, lattice mismatch has been controlled within 0.01%. The room temperature performance of 10**-4cm\ulcornerarea PIN PD at a bias voltage of -5V were` quantum efficiency(with no antireflection coating)=60% for 1.3\ulcorner light source, dark current\ulcorner5nA, and capacitance\ulcornerpE. Frequency response measurement of packaged PIN PD has shown that cut-off frequency (f-3dB) was 961MHz. This PD has shown a good eye pattern when it was incorporated in a 565Mbps optical receiver.

  • PDF

Design of Respiratory Sensor System for polysomnography using Thermocouple (Polysomnography를 위한 열전대 호흡센서 시스템의 설계)

  • 우용규;정도언;박광석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.121-123
    • /
    • 2000
  • Changes in breathing pattern and apnea both can be !he result of sleep disorders. The focus of this paper is to develop methodologies to monitor the breathing pattern and to detect apnea. An accurate recording of the respiratory phase can be carried out with different methods. One of these methods is the use of a thermocouple, which reacts to the variation in air temperature, placed in the nose and mouth of the patient. The K-type thermocouple was used because it has high reliability, thermo-stability, and good corrosion resistance. And also, it has a considerable long time constant that gives a low cut-off frequency, well below the respiratory frequency and thereby causing a large phase difference. The result showed that timing of respiration was accurately obtained with the AD595, amplifier for K-type thermocouple.

  • PDF

Study on synthesis of carbon nanomaterials by hydrogen mixing in counterflow methane diffusion flames (메탄 대향류 확산화염내 수소를 첨가한 탄소나노물질 합성에 관한 연구)

  • Shin, Woo-Jung;Choi, Jung-Sik;Yoon, Seok-Hun;Lee, Hyun-Sik;Choi, Jae-Hyuk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.88-89
    • /
    • 2011
  • The study on synthesis of carbon nanomaterials by H2 mixing in counterflow methane diffusion flames has been experimentally conducted. We have also investigated on effect of catalyst and temperature in flame. The counterflow flame was formed by many kind of gas (fuel side using $CH_4-H_2-N_2$ and oxidizer side $N_2-O_2$) and nitrogen shields discharge on each other side to cut off oxidizer of the atmosphere. Ferrocene was used as a metal catalyst for CNTs synthesis. substrate was used to deposit carbon nanomaterials and these were analyzed by FE-SEM. We could find that carbon nanotubes and many kind of carbon nano materials were formed in Cu wire substrate, through this experiment.

  • PDF

Effect of Oxygen Flux on FTO Thin Films Using DC and RF Sputtering

  • Park, Eun Mi;Lee, Dong Hoon;Suh, Moon Suhk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.2
    • /
    • pp.41-46
    • /
    • 2015
  • Transparent conductive oxides (TCOs) are essential material in optoelectronics such as solar cells, touch screens and light emitting diodes. Particularly TCOs are attractive material for infrared cut off film due to their high transparency in the visible wavelength range and high infrared reflectivity. Among the TCO, Indium tin oxide has been widely used because of the high electrical conductivity and transparency in the visible wavelength region. But ITO has several limitations; expensive and low environmental stability. On the other hands, fluorine doped tin oxide (FTO) is well known for low cost, weather ability and stable in acidic and hydrogen. In this study, two different magnetron sputtering techniques with RF and DC modes at room temperature deposition of FTO thin film was conducted. The change of oxygen content is influence on the topography, transmittance and refractive index.

Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas (혹한기 지역에서의 자연순환형 태양열 시스템 동파방지)

  • Kwon, Jae-Wook;Kim, Jong-Hyun;Hong, Hi-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.