• Title/Summary/Keyword: cut-off low

Search Result 376, Processing Time 0.023 seconds

Intermittent Strip Stock Advancing Accuracy Analysis of a Prototype Pneumatic Cylinder Driven Roll Feeder (공압실린더를 활용한 롤 피더의 간헐적 스트립 스톡 진행 정밀도 분석)

  • So, Jung-Duck;Kwon, Soon-Hong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.3
    • /
    • pp.353-358
    • /
    • 2010
  • This research introduces a new and improved design for a pneumatic cylinder driven roll feeder wherein each of the principal rotating feeder parts is configured so as to have feeding accuracy and to be low manufacturing cost. The feed pitch accuracy of the proposed roll feeder was evaluated by measuring lengths of cut offs of the strip stock with a shear attached to an air press. The air press was designed, manufactured, and mounted on the same table of the proposed roll feeder such that the strip stock maintained horizontal plane until the strip stock entered into the shear. The proposed roll feeder and the air press were designed to be operated automatically by a PLC employed controller. The feed pitch accuracy of the proposed roll feeder was analyzed by setting the pitch as 10, 12.5, and 15mm. At each predetermined feed pitch, the proposed roll feeder was tested 300 times as one test set and replicated three times. The average lengths of the cut offs of the strip stock ranged from 9.98 to 10.13mm, from 12.42 to 12.57mm, and from 14.96 to 15.06mm at the predetermined 10, 12.5, and 15mm feed pitch, respectively, among the total of 900 samples of each feed pitch. Main cause of variation of the length of the cut off of the strip stock fed by the proposed roll feeder was considered to be fluctuation of the air press during recompressing period of the air compressor to pressurize the air in the air tank. The largest difference between the maximum and the minimum length of the cut off was appeared while the air compressor recompressing the air. The air compressor used for this study restricted the air delivered to the proposed roll feeder while it was still running. Thus, this air delivery restriction problem should be improved by stabilizing the air press while the proposed roll feeder is running.

Depression of Stroke Patient자s Family Caregivers and the Relating Factors (뇌졸중 환자 가족 간호자의 우울 및 영향 요인에 관한 연구)

  • 최희정;서문자;김금순;김인자;조남옥
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.6
    • /
    • pp.1531-1542
    • /
    • 2000
  • In this paper, we examined the depression of stroke patient's caregivers and analyzed influencing factors of the depression. The subjects were 215 caregivers who have takencare of stroke survivors in their home. The conceptual model of this study consisted of the caregiver's depression, perceived burden, illness intrusiveness, and patient's ADL. Modified Korean CES-D, modified subjective and objective Burden Scale, Illness intrusiveness(II), and Instrumental Activity of Daily Living(IADL) were used to measure concepts. Path analysis was used to test the model of this study. The results were as follows: 1. The mean depression score was 11.6 which was below the cut-off score of the CES-D. This score indicates that the subjects were higher than normal adults' mean score but not depressive. Eighty-six out of 215 caregivers(40%) were above the cut-off score. This finding was different from previous research results, and the reason might be the patients' capability of ADL. In a group of low capability patient's activities of daily living, caregiver's depression score was 15.5. 2. Caregiver's depression was positively related to caregiver's burden and illness intrusiveness, but negatively related to patient's activities of daily living. 3. The caregiver's perceived burden and illness intrusiveness directly influenced on their depression. Furthermore, the and caregiver's illness intrusiveness led to depression indirectly through their burden. A patient's activities of daily living didn't influence directly on depression but indirectly through caregiver's illness intrusiveness and burden.

  • PDF

Association of Prostate Specific Antigen Concentration with Lifestyle Characteristics in Korean Men

  • Woo, Hee-Yeon;Park, Hyosoon;Kwon, Min-Jung;Chang, Yoosoo;Ryu, Seungho
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5695-5699
    • /
    • 2012
  • We investigated the relationships between demographics, lifestyle characteristics, and serum total prostate specific antigen (PSA) concentration and examined the population-based distribution of total PSA by age among 2,246 Korean men with a median age of 45 years. We obtained data about demographic and lifestyle characteristics based on self-reporting using a quetionnaire. We also performed physical examinations, anthropometric measurements, and biochemical measurements. The PSA concentration increased with age and there was a significant difference in total PSA concentration between the age groups of 21-60 years and >60 years. Age >60 years, height ${\geq}1.8$ m, a low frequency of alcohol consumption, and taking nutritional supplements showed a significantly increased odds ratio for increased PSA when 3.0 ng/mL was chosen as the PSA cut-off level. Smoking status, BMI, percent body fat, diabetes mellitus, fatty liver, herbal medicine use, vitamin use, and diet were not significantly associated with total PSA regardless of the cut-off level. When interpreting a single PSA test, height, alcohol consumption, and nutritional supplement use should be considered, in addition to age.

Practical coherency model suitable for near- and far-field earthquakes based on the effect of source-to-site distance on spatial variations in ground motions

  • Yu, Rui-Fang;Abduwaris, Abduwahit;Yu, Yan-Xiang
    • Structural Engineering and Mechanics
    • /
    • v.73 no.6
    • /
    • pp.651-666
    • /
    • 2020
  • In this study, the spatial variation mechanisms of large far-field earthquakes at engineering scales are first investigated with data from the 2008 Ms 8.0 Wenchuan earthquake. And a novel 'coherency cut-off frequency' is proposed to distinguish the spatial variations in ground motions in the low-frequency and high-frequency ranges. Then, a practical piecewise coherency model is developed to estimate and characterize the spatial variation in earthquake ground motions, including the effects of source-to-site distances, site conditions and neighboring topography on these variations. Four particular earthquake records from dense seismograph arrays are used to investigate values of the coherency cut-off frequency for different source-to-site distances. On the basis of this analysis, the model is established to simulate the spatial variations, whose parameters are suitable for both near- and far-field earthquake conditions. Simulations are conducted to validate the proposed model and method. The results show that compared to the existing models, the proposed model provides an effective method for simulating the spatial correlations of ground motions at local sites with known source-to-site distances.

Determination of plastic concrete behavior at different strain rates to determine Cowper-Symonds constant for numerical modeling

  • Nateghi, Reza;Goshtasbi, Kamran;Nejati, Hamid Reza
    • Computers and Concrete
    • /
    • v.26 no.3
    • /
    • pp.227-237
    • /
    • 2020
  • Strain rate investigations are needed to calibrate strain-rate-dependent material models and numerical codes. An appropriate material model, which considers the rate effects, need to be used for proper numerical modeling. The plastic concrete cut-off wall is a special underground structure that acts as a barrier to stop or reduce the groundwater flow. These structures might be subjected to different dynamic loads, especially earthquake. Deformability of a structure subjected to dynamic loads is a principal issue which need to be undertaken during the design phase of these structures. The characterization of plastic concrete behavior under different strain rates is essential for proper designing of cut-off walls subjected to dynamic loads. The Cowper-Symonds model, as one of the most commonly applied material models, complies well with the behavior of a plastic concretes in low to moderate strain rates and will be useful in explicit dynamics simulations. This paper aims to present the results of an experimental study on mechanical responses of one of the most useful types of plastic concrete and Cowper-Symonds constant determination procedures in a wide range of strain rate from 0.0005 to 107 (1/s). For this purpose, SHPB, uniaxial, and triaxial compression tests were done on plastic concrete samples. Based on the results of quasi-static and dynamic tests, the dynamic increase factors (DIF) of this material in different strain rates and stress state conditions were determined for calibration of the Cowper - Symonds material models.

Analysis of a Synchronizing PLL System for Single-phase Grid-tie Inverters (단상 그리드연결형 인버터의 동기화를 위한 PLL 시스템 해석)

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.447-452
    • /
    • 2008
  • In the paper, the product-type PLL system, which is so suitable for synchronizing a single phase grid voltage is designed. The PLL system is modelled with the small signal analysis. Both the cut-off frequency of low pass filter and the optimal gain are derived by considering the transient response for synchronization as well as a distortion of synchronization signal. Through the simulation studies and experimental results, the transient response and ripple component of synchronization signal are investigated with a variation of both the cut-off frequency and gain in order to verify the performance of design.

Classification-Based Approach for Hybridizing Statistical and Rule-Based Machine Translation

  • Park, Eun-Jin;Kwon, Oh-Woog;Kim, Kangil;Kim, Young-Kil
    • ETRI Journal
    • /
    • v.37 no.3
    • /
    • pp.541-550
    • /
    • 2015
  • In this paper, we propose a classification-based approach for hybridizing statistical machine translation and rulebased machine translation. Both the training dataset used in the learning of our proposed classifier and our feature extraction method affect the hybridization quality. To create one such training dataset, a previous approach used auto-evaluation metrics to determine from a set of component machine translation (MT) systems which gave the more accurate translation (by a comparative method). Once this had been determined, the most accurate translation was then labelled in such a way so as to indicate the MT system from which it came. In this previous approach, when the metric evaluation scores were low, there existed a high level of uncertainty as to which of the component MT systems was actually producing the better translation. To relax such uncertainty or error in classification, we propose an alternative approach to such labeling; that is, a cut-off method. In our experiments, using the aforementioned cut-off method in our proposed classifier, we managed to achieve a translation accuracy of 81.5% - a 5.0% improvement over existing methods.

Enhanced Dynamic Response of SRF-PLL System for High Dynamic Performance during Voltage Disturbance

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.369-374
    • /
    • 2011
  • Usually, a LPF (low pass filter) is used in the feedback loop of a SRF (synchronous reference frame) - PLL (phase locked loop) system because the measured grid voltage contains harmonic distortions and sensor noises. In this paper, it is shown that the cut-off frequency of the LPF should be designed to suppress the harmonic ripples contained in the measured voltage. Also, a new design method for the loop gain of the PI-type controller in the SRF-PLL is proposed with consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and the PI controller gain are designed in coordination according to the steady state and dynamic performance requirements. Furthermore, in the proposed method, the controller gain and the LPF cut-off frequency are changed from their normal value to a transient value when a voltage disturbance is detected. This paper shows the feasibility and usefulness of the proposed methods through the computer simulations and experimental results.

Analysis of Relative Contributions of Tonal Noise Sources in Volute Tongue Region of a Centrifugal Fan (원심팬 볼루트 영역내 순음 소음원의 상대적 기여도 분석)

  • Heo, Seung;Kim, Daehwan;Cheong, Cheolung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.40-47
    • /
    • 2014
  • Interaction between the unsteady flow emitted from the blade of the centrifugal fan and the volute tongue region of fan duct is known as the main noise source of the centrifugal fan. In this paper, the relative contributions of the volute tongue region of the centrifugal fan is analyzed to utilize as the foundation data of low noise design. The internal hybrid CAA (Computational Aero-Acoustics) method is used to predict noise radiated from the main noise source. This method is the noise prediction technique using CFD (Computational Fluid Dynamics), Acoustic analogy, and BEM(Boundary Element Method). The relative contributions of the centrifugal fan volute tongue region using the hybrid CAA method show that the region between the cut-off and the scroll has high contribution than the region between the cut-off and the outlet and the hub region of blade has high contribution than the shroud region of blade. These results is utilized as the important data for the development of low noise centrifugal fan.

Prediction on the Performance of Polymer-Based Mechanical Low-Pass Filters for High-G Accelerometers (고충격 가속도센서용 고분자 기반 기계식 저역통과필터의 성능 예측)

  • Sehwan Song;Junyong Jang;Youlim Lee;Hanseong Jo;Sang-Hee Yoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.262-272
    • /
    • 2023
  • A polymer-based mechanical low-pass filter(m-LPF) for high-g accelerometers makes it possible to remove high-frequency transient noises from acceleration signals, thus ensuring repeatable and reliable measurement on high-g acceleration. We establish a prediction model for performance of m-LPF by combining a fundamental vibration model with the fractional derivative standard linear solid(FD SLS) model describing the storage modulus and loss modulus of polymers. Here, the FD SLS model is modified to consider the effect of m-LPF shape factor (i.e., thickness) on storage modulus and loss modulus. The prediction accuracy is verified by comparing the displacement transmissibility(or cut-off frequency) estimated using our model with that measured from 3 kinds of polymers(polysulfide rubber(PSR), silicone rubber(SR), and polydimethylsiloxane(PDMS)). Our findings will contribute a significant growth of m-LPF for high-g accelerometers.