• Title/Summary/Keyword: cut-off low

Search Result 373, Processing Time 0.05 seconds

A study of Full Width at Half Maximum(FWHM) according to the Filter's Cut off level in SPECT camera (SPECT filter의 cut off level에 따른 반폭치(FWHM) 크기에 관한 연구)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.63-69
    • /
    • 2003
  • Filtering is necessary to reduce statistical noise and to increase image quality in SPECT images. Noises controled by low-pass filter designed to suppress high spatial frequency in SPECT image. Most SPECT filter function control the degree of high frequency supression by chosing a cut of frequency. The location of cut off frequency determines the affect image noise and spatial resolution. If select the low cut off frequency, its provide good noise suppression but insufficient image quantity and high cut off frequencies increase the image resolution but insufficient noise suppression. The purpose of this study was to determines the optimam cut off level with comparison of FWHM according to cut off level in each kiters-Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen and Butterworth filter in SPECT camera. We recorded image along the X, Y, Z-axis with $^{99m}TcO_4$ point source and measured FWHM by use profile curve. We find averaged length is $9.16\;mm{\sim}18.14\;mm$ of FWHM in X, Y, and Z-axis, and Band-limited and Generalized Hamming filters measures 9.16 mm at 0.7 cycle/pixel cut off frequency.

  • PDF

The improvement of cut-off probe for measuring plasma density at hard conditions

  • Kim, Dae-Ung;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.202-202
    • /
    • 2011
  • Diagnostics of plasma density is a key factor for monitoring plasma processing. Various probes are invented to measure plasma density and cut-off probe is a one of the most promising diagnostics tool for measuring plasma density. However, at the low density or high pressure the cut-off probe cannot clearly resolve the cut-off peak. Several reasons make this problem: Cut-off likes peaks caused by cavity resonances and weaken transmission spectrum signal at high pressure. Recently, You et al., have researched mechanism of cut-off probe and we improve the cut-off reliability and sensitivity base on that research. Modified cut-off antenna is adapted and bias cut-off probe method is tried. These experiment results have good agreement with the previous study and show good measurement characteristics.

  • PDF

Cut-off Probe Frequency Spectrum의 물리적 해석

  • Yu, Sin-Jae;Kim, Dae-Ung;Kim, Jeong-Hyeong;Seong, Dae-Jin;Sin, Yong-Hyeon;Na, Byeong-Geun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.200-200
    • /
    • 2011
  • Although the cut-off probe, a precise measurement method for the electron density, is widely used in the industry, the physics on the wave spectrum of the cut-off is not understood yet, only cut-off point frequency containing the information of electron density has been analyzed well. This paper analyzes the microwave frequency spectrum of the cut-off probe to see the physics behind using both microwave field simulation (CST Microwave Studio) and simplified circuit simulation. The result shows that the circuit model well reproduces the cut-off wave spectrum especially in the low frequency regime where the wavelength of the driving frequency is larger than the characteristic length and reveals the physics of transmission characteristics with frequency as resonances between vacuum, plasma and sheath. Furthermore, by controlling the time domain in solver of the microwave simulator, the cut-off like transmission peaks above the cut-off frequency which has been believed as cavity effect is verified as chamber geometry effect. The result of this paper can be used as the basis for the improvement of cut-off probe.

  • PDF

The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter (트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석)

  • Kim, Soo-Hong;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

Quartz를 이용한 마이크로스트립저역필터 특성에 관한 연구

  • U, Hyeong-Gwan;Kim, Eung-Gwon;Song, Jun-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.136-136
    • /
    • 2009
  • It is investigated the cut-off frequency of Z-cut quartz microstrip low pass filter by the variation of applied electric field. Designed microstrip filter was simulated using the Ensemble v7.0(Ansoft). As a result of the experiment, the cut-off frequency showed 50 MHz shift when the applied electric field was 3 kV/cm.

  • PDF

A Fully Differential RC Calibrator for Accurate Cut-off Frequency of a Programmable Channel Selection Filter

  • Nam, Ilku;Choi, Chihoon;Lee, Ockgoo;Moon, Hyunwon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.682-686
    • /
    • 2016
  • A fully differential RC calibrator for accurate cut-off frequency of a programmable channel selection filter is proposed. The proposed RC calibrator consists of an RC timer, clock generator, synchronous counter, digital comparator, and control block. To verify the proposed RC calibrator, a six-order Chebyshev programmable low-pass filter with adjustable 3 dB cut-off frequency, which is controlled by the proposed RC calibrator, was implemented in a $0.18-{\mu}m$ CMOS technology. The channel selection filter with the proposed RC calibrator draws 1.8 mA from a 1.8 V supply voltage and the measured 3 dB cut-off frequencies of the channel selection LPF is controlled accurately by the RC calibrator.

Iron Status of Pregnant Women and Evaluation of Cut-off Levels of Hb, Hct, TIBC, sTfR, sTfR:ferritin Ratio for Assessment of Iron Deficiency (임신여성의 철영양상태와 철결핍상태 판정을 위한 Hb, Hct, TIBC, sTfR 및 sTfR:ferritin 비의 임계수준 평가s)

  • 이종임;임현숙
    • Korean Journal of Human Ecology
    • /
    • v.4 no.1
    • /
    • pp.36-45
    • /
    • 2001
  • This study was performed to determine the changes of maternal iron status during pregnancy cross sectionally, and to evaluate the appropriateness of the cut-off points of hemoglobin (Hb). hematocrit (Hct), serum transferrin receptor (sTfR) and sTfR : ferritin ratio for assessing iron deficiency status based on serum ferritin level (< 12${\mu}g$/L). Serum Hb concentrations in the first trimester were significantly higher (p < 0.05) than those in the second and third trimester. Serum levels of iron and ferritin in the third trimester were significantly lower (p < 0.05) than those in the first and second trimester. On the other hand, sTfR:ferritin ratios in the third trimester were significantly higher (p < 0.05) than those in the first and second trimester. sTfR concentrations did not change significantly during pregnancy. The appropriate cut-off points of Hb were 11.5g/dL for whole period of pregnancy. 12.0g/dL for 1st trimester. and 11.5g/dL for both 2nd and 3rd trimester. The good cut-off points of Hct were 34% for whole period of pregnancy. 36% for 1st trimester. and 34% for both 2nd and 3rd trimester The suitable cut-off points of TIBC were 400${\mu}g$/dL for whole period of pregnancy. 360${\mu}g$/dL for 1st trimester, and 400${\mu}g$/dL for both 2nd and 3rd trimester. Any cut-off point of sTfR could not be selected because of its low sensitivity and specificity. The proper cut-off point of sTfR : ferritin ratio was 600 or 650 for all the periods determined except the first trimester. In conclusion, there were no reliable cut-off levels of sTfR and those of sTfR : ferritin ratio showed low specificity. The cut-off values of Hb and Hct for assessing iron deficiency were slightly higher than the values used to evaluate anemia. Thus, if appropriate cut-off levels were applied, Hb. Hct, or TIBC might be useful indices for evaluating iron deficiency as well as anemia.

  • PDF

Comparative Evaluation of Resolution according to Frequency Change for SPECT (단일광자방출전산화단층촬영(SPECT)을 위한 주파수 변동에 따른 분해능 비교평가)

  • Kim, Sung-Chul;Park, Soo-Yeun;Cho, Young-Kwon;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.322-331
    • /
    • 2009
  • In clinical SPECT, FWHM provides quality information of the images obtained under different observing conditions. Therefore, the purpose of this study was to determine the optimum cut off level with comparison of FWHM according to cut off levels in each filter - Band limited, Sheep-Logan, Hanning, Hamming, Low pass cosine, Parazen and Butterworth filter in a SPECT camera. I recorded images along the X, Y, Z-axis with 99mTcO4 point source and measured FWHM with profile curves. In conclusion, all filters showed the longest figures of FWHM with cut off level 0.4, which has the worst image resolution. The images with cut off level 0.7 showed best image resolution. The shortest average of FWHM in MS2 was $11.07\pm0.07mm$ using the Butterworth filter, in MS3 it was $8.44\pm0.19mm$ through using the Hanning filter.

Analysis and Cut-off Adjustment of Dried Blood Spot 17alpha-hydroxyprogesterone Concentration by Birth Weight (신생아의 출생 체중에 따른 혈액 여과지 17alpha-hydroxyprogesterone의 농도 분석 및 판정 기준 조정)

  • Park, Seungman;Kwon, Aerin;Yang, Songhyeon;Park, Euna;Choi, Jaehwang;Hwang, Mijung;Nam, Hyeongyeong;Lee, Eunhee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.14 no.2
    • /
    • pp.150-155
    • /
    • 2014
  • The measurement of $17{\alpha}$-hydroxyprogesterone ($17{\alpha}$-OHP) in a dried blood spot on filter paper is an important for screening of congenital adrenal hyperplasia (CAH). Since high levels of $17{\alpha}$-OHP are frequently observed in premature infants without congenital adrenal hyperplasia, we evaluated cuts-off based on birth weight and performed validation. Birth weight and $17{\alpha}$-OHP concentration data of 292,204 newborn screening subjects in Greencross labopratories were analyzed. The cut-off values based on birth weight were newly evaluated and validated with the original data. The mean $17{\alpha}$-OHP concentration were 7.25 ng/mL in very low birth weight (VLBW) group, 4.02 ng/mL in low birth weight (LBW) group, 2.53 g/mL in normal birth weight (NBW) group, and 2.24 ng/mL in heavy birth weight (HBW) group. The cut-offs for CAH were decided as follows: 21.12 ng/mL for VLBW and LBW groups and 11.14 ng/mL for NBW and HBW groups. When applied new cut-offs for original data, positive rates in VLBW and LBW groups were decreased and positive rates in NBW and HBW groups were increased. The cut-offs based on birth weight should be used in the screening for CAH. We believe that our new cut-off reduce the false positive rate and false negative rate and our experience for cut-off set up and validation will be helpful for other laboratories doing newborn screening test.

Effect of Cut-off Wall near the Entrance of Spillway Tunnel (비상여수로 입구부의 차수벽 설치 효과 분석)

  • Kim, Gyoo-Bum;Son, Young-Chul;Seo, Kyung-Soo
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.147-153
    • /
    • 2010
  • Cut-off wall with a low permeability can be constructed to prevent groundwater seepage in spillway tunnel areas. Three spillway tunnels are constructed in Im-ha multipurpose dam region and three types of cut-off walls with a variety of directions and scales are designed. As a result of MODFLOW modeling to assess the effect of cut-off wall for three types, groundwater inflows to the tunnels range from 64.26 $m^3/day$ to 65.49 $m^3/day$ and also they through a cut-off wall section from a reservoir do from 44.08 $m^3/day$ to 45.31 $m^3/day$ and it does not show any significant difference among them. Therefore, a construction process and an environmental conservation rather than the effectiveness of cut-off wall need to be considered to select the best cut-off wall in this region.