• Title/Summary/Keyword: cut

Search Result 8,829, Processing Time 0.042 seconds

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.

A Study on the Reflective Property of Trends in Fashion Shows - Focused on Three Designing Factor of the Silhouette, the Detail, the Color and the Fashion Image - (패션쇼의 트렌드 반영성(反映性)에 관(關)한 연구(硏究) - 실루엣, 디테일, 색상(色相), 패션 이미지 등(等) 4가지 디자인 요소(要素)를 중심(中心)으로 -)

  • Lee, Myung-Hee
    • Journal of Fashion Business
    • /
    • v.3 no.4
    • /
    • pp.147-160
    • /
    • 1999
  • This paper is intended to compare and analyze the fashion trends that were introduced in the recent shows, held abroad and in Korea, so as to investigate how well the designers in Taegu and Kyungbuk (TK) area are keeping up with the international vogue. The research has done, analyzing Pret-a-Porter in Paris and the three events held in the TK area in 1997 -The Taegu Collection, Kyungbuk Fashion Festival and Textile & Apparel Fair and using reference pictures and documentary records. In order to investigate the trends the research is divided by four groups which are the silhouette, the detail, the color and the Fashion image and has done with the help of three postgraduate students. The results are as follows. 1. The Silhouette The slim-line has the greatest importance in the silhouette analysis of the recent collections. Like Elongated and Fit & Flare, tight-fitting and female-line were also appeared quite a lot. Compared with foreign collection, Korean collections put the bigger importance on the slim-line. 2. The Detail The printings, using paintings and plant-logos had the large portion of the accessories in both foreign and Korean collections. Draw string and wrap style were also presented a lot. Especially, at the Korean collections, layerd, corsage, and craft accent were emphasized, too. As for the necklines the similarity was found over the four events considering. Camisole neckline and halter neck were presented the most, and bared top, Vneckline, boat and low-neck which can highlight the feminity were often appeared as well. Considering collars, tailored and peaked collars which are frequently used for the jackets, were usually shown at the collections. Like convertable, shirts, wing and Italian collar, the collars that can be applied for the sports wears were presented a lot. Virtually no variation of design was found in the sleeve analysis. While set-in-sleeve and sleeveless were found commonly, not so many ornaments were added to the sleeves. The ankle and knee length for the pants and skirts were common. Furthermore, including the micro-mini, showing extremely feminine style the mini-style had the 20% portion of the skirt-length. Unbalanced lengths, using bias-cut were presented quite a lot on the runways. Deep slit skirts, wide pants and irregular hem skirts were in vogue. On the runways of Paris, more than 21% of the design was the burmuda pants. 3. The Color Red and Blue were in vogue in the four collections considering. Sometimes, yellowish was combined in Korean collections. Black and pale tone were appeared to be in fashion also with light grayish, moderate and deep tone. 4. The Fashion image As for the fashion image, feminine-decorative trend amounted to the large percentage in korean collections. At the foreign collection feminine-decorative trend and feminine trend were predominant, then mannish trend and simple trend were apeared equally. The research shows that TK area and foreign collections are fairy similar, which means that the designers in TK area have been making their efforts to satisfy the clients who have the international minds. However, compared with foreign collections, TK collections were apprered to be strongly inclined to only a few trends. Consequently the season trends are not as diverse as the foreign trends, which cannot satisfy the fashion taste of the clients in TK area. The local designers should know the tendency and the taste of the clients and make the more efforts to read local clients' mind.

  • PDF

A Study on the Well-being Related Awareness and Dietary Life Pattern in Urban Housewives (도시 주부들의 웰빙에 대한 인식과 식생활유형에 대한 연구)

  • Park, Young-Sim;Myung, Choon-Ok;Lee, Ki-Wan;Nam, Hae-Won
    • Journal of the Korean Society of Food Culture
    • /
    • v.20 no.5
    • /
    • pp.574-583
    • /
    • 2005
  • To investigate the importance and practice of well-being related dietary life pattern such as purchasing food materials, food habits and eating out, a survey was conducted by questionnaire and 5-point Likert score in Seoul and Gyeonggi-Do, September, 2004 and April, 2005. The responses of 732 housewives who were over 40 years were analyzed by SPSS package program. The results were as follows. Most of them were 40-49 years(74.4%), graduated highschool (66.6%) and their family type was nuclear family type(81.4%). Almost half of them had full-time job (37.1%) and part time job (15.4%). The average importance score of 'food habits', 'purchasing food materials' and 'eating out' were $4.15{\pm}0.91,\;4.06{\pm}0.96\;and\;3.25{\pm}1.01$ respectively. But the average practice score of 'food habits' was greater($3.58{\pm}1.06$) than 'purchasing food materials ($3.19{\pm}1.19$)' and 'eating out($2.54{\pm}1.05$)'. Among 5 types of 'food habits', the type of 'cut down on eating fast food' had the greatest score of importances ($4.31{\pm}0.97$) but the difference between importance and practice was greatest(0.94). Also 'consume home-made food rather than processed or ready to food' showed great scores in importance ($4.28{\pm}0.87$) and practice($3.87{\pm}1.04$). 'Consume fruits and vegetables rather than meats' and 'avoid heavy use of oils' had the importance score of $4.04{\sim}4.19$. But the practice score of 'avoid heavy use of oils' was the lowest($3.39{\pm}0.97$). Among four types of purchasing of food materials, 'purchase domestic agricultural food' was greatest($4.37{\pm}0.78$) and 'don't purchase genetically modified food' 'purchase organic food' and 'purchase whole grain products' were also great ($3.92{\sim}3.99$). But the practice score of 'purchase organic/low chemical foods($2.77{\pm}0.98$)' and 'don't purchase genetically modified food($2.99{\pm}1.41$)' were lowest. 'Go to well being restaurant' in three types of 'eating out' showed greatest in importance($3.35{\pm}0.96$) but the practice score($2.47{\pm}0.10$) was lower than the importance score. Also 'choose menu with comparing calories' had the lower score in practice($2.45{\pm}1.06$) rather than importance score($3.22{\pm}1.03$). In regarding to 'food habits', the importance score were significantly affected by type of food expense (p<0.05) and health status (p<0.05). The importance score of 'purchase food materials' were significantly affected by the type of food expense (p<0.001), type of residence(p<0.05), and self assessment of weight(p<0.05). Monthly income, especially more 400 million won, was the commonly significant effector in practice score of 'purchase food materials' and 'eating out'.

Tensile Behavior of Hybrid Fiber Reinforced Cement Composite According to the Hooked Steel Fiber and Polyvinyl Alcohol Fiber Blending Ratio and Strain Rate (후크형 강섬유와 폴리비닐알코올 섬유의 혼합 비율과 변형속도에 따른 하이브리드 섬유보강 시멘트복합체의 인장거동)

  • Son, Min-Jae;Kim, Gyu-Yong;Lee, Sang-Kyu;Kim, Hong-Seop;Nam, Jeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.98-105
    • /
    • 2017
  • In this study, the fiber blending ratio and strain rate effect on the tensile behavior of hybrid fiber reinforced cement composite was evaluated. Hooked steel fiber and polyvinyl alcohol fiber were used for reinforcing fiber. The fiber blending ratio of HSF+PVA were 1.5+0.5, 1.0+1.0 and 0.5+1.5vol.%. As a results, the tensile strength, strain capacity and fracture toughness of the hooked steel fiber reinforced cement composites were improved by the increase of the bond strength of the fiber and the matrix according to increase of strain rate. However, the tensile stress sharply decreased after the peak stress because of the decrease in the number of straightened pull-out fibers by micro cracks in the matrix around hooked steel fiber. On the other hand, PVA fiber showed cut-off fracture at strain rate $10^{-6}/s$ with multiple cracks. However, at the strain rate $10^1/s$, the multiple cracks and strain capacity were decreased because of the pull-out fracture of PVA fiber. The HSF1.5PVA0.5 shown the highest tensile strength because the PVA fiber suppressed the micro cracks in the matrix around the hooked steel fiber and improved the pull-out resistance of hooked steel fiber. Thus, DIF of strain capacity and fracture toughness of HSF1.5PVA were greatly improved. In addition, the synergistic response of fracture toughness was positive because the tensile stress was slowly decreased after the peak stress by improvement of the pull-out resistance of hooked steel fiber at strain rate $10^1/s$.

THE INFLUENCE OF THE VITAL BLEACHING AGENTS ON TRANSLUCENCY OF THE BOVINE ENAMEL (생활치 미백제가 우치 법랑질의 투명도에 미치는 영향)

  • Kim, Dong-Jun;Kim, Young-Ju;Kim, Hak-Geun;Park, Eun-Jong;Seo, Eun-Ju;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.178-183
    • /
    • 2005
  • This study was done to evaluate whether vital bleaching agents could influence on the translucency of the bovine enamel. The anterior bovine teeth that were extracted one day before and without any gross discoloration were obtained and then were preserved in physiologic saline. 6 mm cylindrical tooth specimens were fabricated with diamond puncher perpendicularly on labial surface of bovine tooth. After embedded in transparent acrylic resin with labial surface being exposed, they were cut to a thickness of 1.2 mm with low speed diamond saw (Isomat, Buehler Co., Lake Bluff, IL, USA). They were smoothly ground to 1 mm thickness of enamel with sandpaper. 24 specimens were randomly divided into 3 groups and control group respectively. Opalescence (10% carbamide peroxide, Ultradent, South Jordan, USA), Rembrandt (10% carbamide peroxide, DenMat, USA) and Opalescence F (15% carbamide peroxide with fluoride, Ultradent, USA) were applied on labial sides of the bovine enamel for 7 days (bleaching agents were reapplied every 24 hours) and the opposite surface was contacted to cotton that soaked in distilled water. The control group was soaked in distilled water. Three stimulus value X, Y and Z were evaluated with colorimeter (Color ' Color Differencerneter, Model TC-6FX, Tokyo Denshoku Co., Japan) on the labial surface of all specimen three times on white and black background plate before the bleaching agents were applied and on 3rd, 5th and 7th day after applied. The degree of translucency was normally assessed by measuring the inverse property, opacity (contrast ratio). 10% Opalescence, 15% Opalescence-F, and control group showed no significant variation in the translucency of bovine enamel, However Rembrandt decreased the translucency of it (p < 0.01).

EFFECT OF VARIOUS RESIN CEMENTS TO THE SHEAR BOND STRENGTH IN THE ADHESION BRIDGE (접착성가공의치에서 세멘트 종류가 전단결합강도에 미치는 영향)

  • Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.791-799
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength of adhesion bridge by various resin cements. One hundred and foully 1st premolars were used. The teeth were cut below 2mm from CEJ and the coronal portions were used. The coronal portions were embeded with the acrylic resin and trimmed with sic paper until the flat plane with ${\phi}$ 4mm above acrylic resin sticks in height 5mm were casted with nonprecious metal and the using surfaces were treated with sic paper from #200 to #1200 and polished with alminum oxide paste. And then, the using surfaces were sandblasted and treated with the electrochemical etching. The teeth were divided into three groups of fourty two each. In group I, teeth and specimens were cemented with Panavia 21 In group II, teeth and specimens were cemented with Superbond In group I, teeth and specimens were cemented with All-Bond & composite resin cement Each group was subdivided into three subgroups according to the storage period ; one-day storage, fifteen-day storage, and thirty-day storage. The special jig was made. Then, the specimen and jig were mounted to Instron Universal Testing Machine and the failure were measured. The results were as follows. 1. There was statisfically significant difference between the failure loads of group I and group II and III after one day storage(P<0.01), 2. There was statisfically significant difference between the failure loads of group II and group I and III and between group I and group III at fifteen day storage(P<0.01). 3. There was statisfically significant difference between the failure loads of group I and II and group III after thirty day storage(P<0.01). 4. There was statisfically significant difference between the failure loads of one day storage and fifteen and thirty days storages in group III (P<0.01).

  • PDF

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

The Usefulness of the Berlin Questionnaire as a Screening for Obstructive Sleep Apnea in a Sleep Clinic Population (수면 클리닉을 내원한 환자에서 폐쇄성수면무호흡의 선별을 위한 베를린 설문의 유용성)

  • Kang, Hyeon-Hui;Kang, Ji-Young;Lee, Sang-Haak;Moon, Hwa-Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.18 no.2
    • /
    • pp.82-86
    • /
    • 2011
  • Objectives: The Berlin Questionnaire (BQ) has been used to help identify patients at high risk of having sleep apnea in primary care. But it has not been validated in a sleep clinic for Korean patients. The aim of this study is to evaluate the usefulness of the BQ as a screening tool for obstructive sleep apnea (OSA) for Korean patients in a sleep clinic. Methods: The BQ was prospectively applied to 121 subjects with OSA suspicion who visited to our sleep clinic. All subjects performed overnight polysomnography. OSA was defined as an apnea-hypopnea index (AHI) ${\geq}5$. We investigated the sensitivity, specificity, positive and negative predictive values of the BQ according to severity by AHI. Results: In 121 subjects, 73.6% were males, with a mean age of $48.8{\pm}13.0$ years. Twenty-five (20.6%) patients did not have OSA (AHI<5), 30 (25%) patients had mild OSA ($AHI{\geq}5$ and <15), 26 (21.4%) had moderate ($AHI{\geq}15$ and <30), and 40 (33%) had severe OSA ($AHI{\geq}30$). The BQ identified 69.4% of the patients as being at high risk for having OSA. The sensitivity and specificity of the BQ were 71.9% and 40%, for $AHI{\geq}5$, 75.8% and 38.2% for $AHI{\geq}15$, 77.5% and 34.6% for $AHI{\geq}30$, respectively. The positive and negative predictive values of the BQ were 82.1% and 27.0% for $AHI{\geq}5$, respectively. Positive and negative likelihood ratios were 1.2 and 0.7, and the overall diagnostic accuracy of the BQ was 65.3%, using an AHI cut-off of 5. Conclusion: Due to modest sensitivity and low specificity, the BQ does not seem to be an appropriate tool for identifying patients with obstructive sleep apnea in a sleep clinic population.

Utility of FDG-PET in Solitary Pulmonary Nodules and the Relationship Between Standardized Uptake Values of PET and Serum Glucose (폐 결절에서 FDG-PET의 유용성과 표준섭취계수와 혈당농도의 상관관계)

  • Kim, Kyu Sik;Lim, Sung Chul;Ko, Young Chun;Park, Kyung Ha;Ju, Jin Young;Jo, Kae Jung;Kim, Soo Ok;Oh, In Jae;Kim, Yu Il;Kim, Young Chul;Kim, Sung Min;Song, Ho Chun;Bom, Hee Seung;Park, Kyung Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.589-596
    • /
    • 2003
  • Background : The solitary pulmonary nodule(SPN) presents a diagnostic dilemma to the physician and the patients in the our nation with high incidence of tuberculoma. We could not exclude whether the SPN was benign or malignant by the change of the size at chest radiograph and findings of chest CT. Recently, positron emission tomography(PET) have been tried as the differential diagnostic method of SPN. We evaluated the efficacy of PET for differentiating malignant from benign SPN and the relationship between standardized uptake values(SUV) of PET and serum glucose. Method : Between January 2001 and July 2002, sixty-one patients with pulmonary nodule were examined by the chest CT and PET. The SPN has been finally diagnosed by the transthorasic needle aspiration and biopsy, bronchoscopic biopsy, and open lung biopsy. Results : Forty eight patients had a malignant nodule(23 squamous cell lung carcinoma, 16 adenocarcinoma, 9 small cell lung cancer) and thirteen patients had a benign nodule(3 tuberculoma, 9 inflammatory granuloma, 1 cryptococcosis). The mean size of malignant and benign nodule was 40.6 mm and 20.0 mm, respectively. All malignant nodules showed a marked increase in 18 fluorodeoxyglucose (FDG) uptake. Mean SUV of malignant was $9.52{\pm}5.20$ and benign nodule was $1.61{\pm}3.60$. There were false positive cases with an increase in 18-FDG uptake (2 tuberculoma, 1 inflammatory granuloma). The SUV of malignant nodule in diabetes patients has no difference in non diabetes patients($9.10{\pm}4.51$ vs $9.65{\pm}5.46$). The sensitivity and specificity of the PET scan for SPN were 100%, 77%, respectively. The positive and negative predictive values were 94% and 100%. Conclusion : PET scanning showed highly accurate result in differentiating the malignant and benign SPN. There were no significant differences between the SUV and serum glucose in the patients with lung cancer.

Prognostic Utility of the Soluble Triggering Receptor Expressed on Myeloid Cells-1 in Patients with Acute Respiratory Distress Syndrome (급성호흡곤란증후군 환자에서 Soluble Triggering Receptor Expressed on Myeloid Cells-1의 예후인자로서의 유용성)

  • Huh, Jin Won;Jung, Hoon;Lim, Chae-Man;Koh, Younsuck;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.4
    • /
    • pp.301-307
    • /
    • 2008
  • Background: The triggering receptor expressed on myeloid cells-1 (TREM-1) is an activating receptor that is expressed on the surface of neutrophils and mature monocytes when stimulated with several microbial components, which can amplify the inflammatory response. This study analyzed the prognostic value of the sTREM-1 levels in patients with acute respiratory distress syndrome (ARDS). Methods: The bronchoalveolar lavage (BAL) fluid and blood was collected prospectively from 32 patients with ARDS, 15 survivors and 17 nonsurvivors. An enzyme-linked immunosorbent assay was performed to measure the sTREM-1. The following data was obtained: APACHE II score, Clinical Pulmonary Infection Score (CPIS), BAL fluid analysis, C-reative protein. Mortality in the ICU was defined as the end point. Results: The serum sTREM-1 level was significantly higher in the nonsurvivors than survivors ($54.3{\pm}10.3pg/ml$ vs. $22.7{\pm}2.3pg/ml$, p<0.05). The sTREM-1 level in the serum, but not in the BAL fluid, was an independent predictor of the ICU mortality (OR: 22.051, 95% CI: 1.780~273.148, p<0.016), and a cut-off value of ${\geq}33pg/ml$ yielded a diagnostic sensitivity of 71% and specificity of 93%. Conclusion: The serum sTREM-1 level may be a useful predictor of the outcome of ARDS patients.