• Title/Summary/Keyword: curves

Search Result 8,494, Processing Time 0.034 seconds

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Three Phases and Water Characteristics of Horticultural Substrates (원예(園藝) 상토재료(床土材料)의 삼상(三相)과 수분특성(水分特性))

  • Jo, In-Sang;Hyun, Byung-Keun;Cho, Hyun-Jun;Jang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.1
    • /
    • pp.56-61
    • /
    • 1997
  • A study was carried out to find out the basic information in physical properties for selection and manufacturing the good seedling media through the analysis of the physical properties, such as particle size, water retention and three phases of the major horticultural substrates. Easily available water(EAW), the water contents between 1kPa and 5kPa water potental, was highest in peatmoss with 39%, and perlite 34.0%, vermiculite 16.9%, but the values of osmunda and bark were lower than 4.8%. Water buffering capacity(WBC), the water content between 5kPa and 10kPa, was 6.1% in peatmoss and 2.3% in vermiculite but it was lower than 1.0% in other substrates. To adjust the suitable range of water potential at crossing point of water and air curves to 1.5~2.5kPa, more finer materials were needed in osmunda and bark, and more coarser materials must be added to peatmoss, perlite and vermiculite. Water potentials of substrates in saturated pot condition were equivalent to 2.2kPa in peatmoss and others were ranged in 1.0kPa to 4.3kPa of water potential in pressure chamber.

  • PDF

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Cold shock sensitive growth of Bacillus subtilis mutants deleted for genes involved in fatty acid synthesis (지방산 생합성 관련 유전자 결손 Bacillus subtilis 균주들의 저온충격 민감성 생장)

  • Kim, Do Hyung;Lee, Sang Soo
    • Korean Journal of Microbiology
    • /
    • v.54 no.1
    • /
    • pp.9-17
    • /
    • 2018
  • To investigate the role of bkdR, sigL, yplP, and des genes which were known to be involved in fatty acid synthesis and sensitive at low temperature, deletion mutants of Bacillus subtilis CU1065 and JH642 were constructed. To determine the low temperature sensitivity of these genes, we compared the growth curves of cells at $37^{\circ}C$ and $15^{\circ}C$. At $37^{\circ}C$, wild type and deletion mutants showed almost similar growth but only bkdR deletion strain at $15^{\circ}C$ showed very slow growing compared with wild type. At $15^{\circ}C$ sigL and yplP deletions were somewhat slower or similar to those of wild type strain. Double and triple mutants for bkdR, sigL, yplP deletions were constructed and grown at $20^{\circ}C$ in LB agar to investigate cold sensitive growth. Double or triple deletions including bkdR deletion showed cold sensitive growing. In order to identify more clearly cold sensitive growth, the experiments were carried out under cold shock conditions in which the temperature was lowered from $37^{\circ}C$ to $15^{\circ}C$ at the point of 0.4 optical densities at 600 nm. In these cold shock experiments, only bkdR deletion showed significantly lower growing and additional des deletion increases cold sensitivity. The bkdR activates the bkd operon, which catabolized isoleucine, valine and leucine, amino acids and produce precursors for the synthesis of branched fatty acids. At cold shock growing of bkdR deletion strain, isoleucine recovered cold sensitivity of bkdR deletion but valine did not restore cold sensitivity. Isoleucine is used as a precursor for the synthesis of anteiso-branched fatty acids. On the other hand, valine is used as a precursor for the synthesis of iso-branched fatty acids. This indicates that anteiso-branched fatty acid plays an important role at the cold shock condition.

Relationship of Fixation Disparity and Heterophoria According to Fixation Distance (원, 근거리에서 주시시차와 사위와의 관계)

  • Kim, Chang-Jin;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • Purpose: This study measured Y-intercept that means a fixation disparity, X-intercept that means a associated phoria and slope of a fixation disparity curve (FDC), which are variables of dissociated phoria and the FDC. We searched for the result value and examined the direction, distribution pattern and a variable that give an most affect on dissociated phoria and the FDC at distance and near. Also this study examined that there were statistically significant differences between distance and near, comparing the result value. Methods: We measured the dissociated phoria and the fixation disparity for 51 subjects at distance and near in June, 2007. All subjects ranged from 20 to 25 years of age (average 21.72${\pm}$1.88 years old) and had no eye disease. At distance the dissociated phoria measured with the distance MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the modified Mallett Far Unit (Bernell co., USA). At near the dissociated phoria measured with the near MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the Wesson fixation disparity card (American Optical co., USA). Results: The percentage distribution of types of fixation disparity curves was that at distance prevalence of Type I (74.6%) was the highest, followed by Type IV (17.6%) and Type II (3.9%), Type III (3.9%) and that at near prevalence of Type I (53.0%) was the highest, followed by Type III (29.4%), Type IV (13.7%) and Type II (3.9%). 2. There were significantly correlation in dissociated phoria, fixation disparity (Y-intercept) and associated phoria (X-intercept). 3. The fixation disparity at distance was most affected by associated phoria (X-intercept) (p=0.000). The distance dissociated phoria was most affected by fixation disparity (Y-intercept) (p=0.342), but the influence was weak. 4. The fixation disparity at near was most affected by associated phoria (X-intercept) (p=0.000). The near also dissociated phoria was most affected by associated phoria (X-intercept) (p=0.009). The result that compared the each variables with the same variables at distance and near had statistically significant on paired t-test for among dissociated phoria (t=7.529, p=0.000), X-intercept (t=5.860, p=0.000), the Y-intercept (t=4.640, p=0.000) but slope of the FDC did not differ significant (t=1.336 p=0.188). Conclusions: Relationship of fixation disparity and Heterophoria had close correlation at distance and near.

  • PDF

Experimental Studies on the Effects of Chunggeumtang (청금탕(淸金湯)의 효능(效能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Eung-Sik;Lee, Si-Hyeong
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.1-26
    • /
    • 1997
  • Chunggeumtang has been used in Korea for many centuries as a treatment for respiratory disease. The effect of Chunggeumtang on tracheal smooth muscle is not konwn. The purpose of the present study is to determine the effect of Chunggeumtang on histamine and acetylcholine induced tracheal smooth muscle contraction in rats and guinea pigs. Guinea pig(500g, male) and Sprague Dawley rats (250g, male) were killed by $CO_2$ exposure and a segment (8-10mm) of the thoracic trachea from each rat and guinea pig was cut into equal swegments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force diplacement transducers under 0.5g loading tension. The dose of histamine (His) and acetylcholine (Ach) which evoked 50% of maximal response ($ED_{50}$) was obtained from cumulative dose response curves for histamine and acetylcholine($10^{-7}{\sim}10^{-4}M$). Contractions evoked by His ($ED_{50}$) and Ach ($ED_{50}$) were inhibited significantly by Chunggeumtang. In guinea pig tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $6.1%after\;30{\mu}l/ml$ Chunggeumtang, and 49.4% (p<0.01) after $100{\mu}l/ml$ Chunggeumtang. In rat tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $6.7%\;after\;30{\mu}l/ml$ Chunggeumtang, and $54.2%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. Also, in guinea pig tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $30.6%\;(p<0.05)\;after\;30{\mu}l/ml$ Chunggeumtang, and $53.0%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. In rat tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $24.1%\;(p<0.05)\;after\;30{\mu}l/ml$ Chunggeumtang, and $55.3%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. Propranolol and indomethacin($10^{-7}M$) slightly but significantly attenuated the inhibitory effects of Chunggeumtang. Following treatment with propranolol, the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 27.6% in guinea pig induced by acetylcholine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 28.7% (p<0.05) in rat induced by acetylcholine contraction and the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 16.2% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 28.7% (p<0.05) in rat induced by histamine contraction. Indomethacin, the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 20.0% in guinea pig induced by acetylcholine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 16.9% (p<0.05) in rat induced by acetylcholine contraction and the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 16.4% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 23.1% (p<0.05) in rat induced by histamine contraction. Methylene blue($10^{-7}M$) did not significantly alter the inhibitory effect of Chunggeumtang. Also, I could find the effects of Chunggeumtang and Chunggeumtanggamorphine on the tracheal smooth muscle in guinea pig and rat did not change significantly. These results indicate that Chunggeumtang can relax histamine and acetylcholine-induced contraction of guinea pig and rat tracheal smooth muscle, and that this inhibition involves sympathetic effects and the release of cyclooxygenase products.

  • PDF

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF