• Title/Summary/Keyword: curves

Search Result 8,446, Processing Time 0.039 seconds

A Numerical and Experimental Study for Fry-drying of Various Sludge (슬러지 유중 건조에 대한 전산 해석 및 실험적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Kim, Byeong-Gap;Hwang, Min-Jeong;Jang, Dong-Soon;Ohm, Tae-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • The basic principle of fry drying process of sludge lies in the rapid pressure change of sludge material caused by the change of temperature between oil and moisture due to the difference of specific heat. Therefore, the rapid increase of pressure in drying sludge induces the efficient moisture escape through sludge pores toward heating oil media. The object of this study is to carry out a systematic investigation of the influence of various parameters associated with the sludge fry drying processes on the drying efficiency. To this end, a series of parametric experimental investigation has been made together with the numerical calculation in order to obtain typical drying curves as function of important parameters such as drying temperature, sludge diameter, oil type and sludge type. In the aspect of frying temperature, especially it is found that the operation higher than $140^{\circ}C$ was favorable in drying efficiency regardless of type of waste oil employed in this study. The same result was also noted consistently in the investigation of numerical calculation, that is, in that the sludge particle drying was efficiently made over $140^{\circ}C$ irrespective of the change of particle diameter. As expected, in general, the decrease of diameter in sludge was found efficient both experiment and numerical calculation in drying due to the increased surface area per unit volume. In the investigation of oil type and property, the effect of the viscosity of waste oil was found to be more influential in drying performance. In particular, when the oil with high viscosity, a visible time delay was noticed in moisture evaporation especially in the early stage of drying. However, the effect of high viscosity decreased significantly over the temperature of $140^{\circ}C$. There was no visible difference observed in the study of sludge type but the sewage sludge with a slightly better efficiency. The numerical study is considered to be a quite useful tool to assist in experiment with more detailed empirical modeling as further work.

Gait Analysis of a Pediatric-Patient with Femoral Nerve Injury : A Case Study (대퇴신경 손상 환아의 보행분석 : 사례연구)

  • Hwang, S.H.;Park, S.W.;Son, J.S.;Park, J.M.;Kwon, S.J.;Choi, I.S.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.165-176
    • /
    • 2011
  • The femoral nerve innervates the quadriceps muscles and its dermatome supplies anteromedial thigh and medial foot. Paralysis of the quadriceps muscles due to the injury of the femoral nerve results in disability of the knee joint extension and loss of sensory of the thigh. A child could walk independently even though he had injured his femoral nerve severely due to the penetrating wound in the medial thigh. We measured and analyzed his gait performance in order to find the mechanisms that enabled him to walk independently. The child was eleven-year-old boy and he could not extend his knee voluntarily at all during a month after the injury. His gait analysis was performed five times (GA1~GA5) for sixteen months. His temporal-spatial parameters were not significantly different after the GA2 or GA3 test, and significant asymmetry was not observed except the single support time in GA1 results. The Lower limb joint angles in affected side had large differences in GA1 compared with the normal normative patterns. There were little knee joint flexion and extension motion during the stance phase in GA1 The maximum ankle plantar/dorsi flexion angles and the maximum knee extension angles were different from the normal values in the sound side. Asymmetries of the joint angles were analyzed by using the peak values. Significant asymmetries were found in GA1with seven parameters (ankle: peak planter flexion angle in stance phase, range of motion; ROM, knee: peak flexion angles during both stance and swing phase, ROM, hip: peak extension angle, ROM) while only two parameters (maximum hip extension angle and ROM of hip joint) had significant differences in GA5. The mid-stance valleys were not observed in both right and left sides of vertical ground reaction force (GRF) in the GA1, GA2. The loading response peak was far larger than the terminal stance peak of vertical ground reaction curve in the affected side of the GA3, GA4, GA5. The measured joint moment curves of the GA1, GA2, GA3 had large deviations and all of kinetic results had differences with the normal patterns. EMG signals described an absence of the rectus femoris muscle activity in the GA1 and GA2 (affected side). The EMG signals were detected in the GA3 and GA4 but their patterns were not normal yet, then their normal patterns were detected in the GA5. Through these following gait analysis of a child who had selective injuries on the knee extensor muscles, we could verify the actual functions of the knee extensor muscles during gait, and we also could observe his recovery and asymmetry with quantitative data during his rehabilitation.

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Three Phases and Water Characteristics of Horticultural Substrates (원예(園藝) 상토재료(床土材料)의 삼상(三相)과 수분특성(水分特性))

  • Jo, In-Sang;Hyun, Byung-Keun;Cho, Hyun-Jun;Jang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.1
    • /
    • pp.56-61
    • /
    • 1997
  • A study was carried out to find out the basic information in physical properties for selection and manufacturing the good seedling media through the analysis of the physical properties, such as particle size, water retention and three phases of the major horticultural substrates. Easily available water(EAW), the water contents between 1kPa and 5kPa water potental, was highest in peatmoss with 39%, and perlite 34.0%, vermiculite 16.9%, but the values of osmunda and bark were lower than 4.8%. Water buffering capacity(WBC), the water content between 5kPa and 10kPa, was 6.1% in peatmoss and 2.3% in vermiculite but it was lower than 1.0% in other substrates. To adjust the suitable range of water potential at crossing point of water and air curves to 1.5~2.5kPa, more finer materials were needed in osmunda and bark, and more coarser materials must be added to peatmoss, perlite and vermiculite. Water potentials of substrates in saturated pot condition were equivalent to 2.2kPa in peatmoss and others were ranged in 1.0kPa to 4.3kPa of water potential in pressure chamber.

  • PDF

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Cold shock sensitive growth of Bacillus subtilis mutants deleted for genes involved in fatty acid synthesis (지방산 생합성 관련 유전자 결손 Bacillus subtilis 균주들의 저온충격 민감성 생장)

  • Kim, Do Hyung;Lee, Sang Soo
    • Korean Journal of Microbiology
    • /
    • v.54 no.1
    • /
    • pp.9-17
    • /
    • 2018
  • To investigate the role of bkdR, sigL, yplP, and des genes which were known to be involved in fatty acid synthesis and sensitive at low temperature, deletion mutants of Bacillus subtilis CU1065 and JH642 were constructed. To determine the low temperature sensitivity of these genes, we compared the growth curves of cells at $37^{\circ}C$ and $15^{\circ}C$. At $37^{\circ}C$, wild type and deletion mutants showed almost similar growth but only bkdR deletion strain at $15^{\circ}C$ showed very slow growing compared with wild type. At $15^{\circ}C$ sigL and yplP deletions were somewhat slower or similar to those of wild type strain. Double and triple mutants for bkdR, sigL, yplP deletions were constructed and grown at $20^{\circ}C$ in LB agar to investigate cold sensitive growth. Double or triple deletions including bkdR deletion showed cold sensitive growing. In order to identify more clearly cold sensitive growth, the experiments were carried out under cold shock conditions in which the temperature was lowered from $37^{\circ}C$ to $15^{\circ}C$ at the point of 0.4 optical densities at 600 nm. In these cold shock experiments, only bkdR deletion showed significantly lower growing and additional des deletion increases cold sensitivity. The bkdR activates the bkd operon, which catabolized isoleucine, valine and leucine, amino acids and produce precursors for the synthesis of branched fatty acids. At cold shock growing of bkdR deletion strain, isoleucine recovered cold sensitivity of bkdR deletion but valine did not restore cold sensitivity. Isoleucine is used as a precursor for the synthesis of anteiso-branched fatty acids. On the other hand, valine is used as a precursor for the synthesis of iso-branched fatty acids. This indicates that anteiso-branched fatty acid plays an important role at the cold shock condition.

Relationship of Fixation Disparity and Heterophoria According to Fixation Distance (원, 근거리에서 주시시차와 사위와의 관계)

  • Kim, Chang-Jin;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • Purpose: This study measured Y-intercept that means a fixation disparity, X-intercept that means a associated phoria and slope of a fixation disparity curve (FDC), which are variables of dissociated phoria and the FDC. We searched for the result value and examined the direction, distribution pattern and a variable that give an most affect on dissociated phoria and the FDC at distance and near. Also this study examined that there were statistically significant differences between distance and near, comparing the result value. Methods: We measured the dissociated phoria and the fixation disparity for 51 subjects at distance and near in June, 2007. All subjects ranged from 20 to 25 years of age (average 21.72${\pm}$1.88 years old) and had no eye disease. At distance the dissociated phoria measured with the distance MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the modified Mallett Far Unit (Bernell co., USA). At near the dissociated phoria measured with the near MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the Wesson fixation disparity card (American Optical co., USA). Results: The percentage distribution of types of fixation disparity curves was that at distance prevalence of Type I (74.6%) was the highest, followed by Type IV (17.6%) and Type II (3.9%), Type III (3.9%) and that at near prevalence of Type I (53.0%) was the highest, followed by Type III (29.4%), Type IV (13.7%) and Type II (3.9%). 2. There were significantly correlation in dissociated phoria, fixation disparity (Y-intercept) and associated phoria (X-intercept). 3. The fixation disparity at distance was most affected by associated phoria (X-intercept) (p=0.000). The distance dissociated phoria was most affected by fixation disparity (Y-intercept) (p=0.342), but the influence was weak. 4. The fixation disparity at near was most affected by associated phoria (X-intercept) (p=0.000). The near also dissociated phoria was most affected by associated phoria (X-intercept) (p=0.009). The result that compared the each variables with the same variables at distance and near had statistically significant on paired t-test for among dissociated phoria (t=7.529, p=0.000), X-intercept (t=5.860, p=0.000), the Y-intercept (t=4.640, p=0.000) but slope of the FDC did not differ significant (t=1.336 p=0.188). Conclusions: Relationship of fixation disparity and Heterophoria had close correlation at distance and near.

  • PDF

Experimental Studies on the Effects of Chunggeumtang (청금탕(淸金湯)의 효능(效能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Eung-Sik;Lee, Si-Hyeong
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.1-26
    • /
    • 1997
  • Chunggeumtang has been used in Korea for many centuries as a treatment for respiratory disease. The effect of Chunggeumtang on tracheal smooth muscle is not konwn. The purpose of the present study is to determine the effect of Chunggeumtang on histamine and acetylcholine induced tracheal smooth muscle contraction in rats and guinea pigs. Guinea pig(500g, male) and Sprague Dawley rats (250g, male) were killed by $CO_2$ exposure and a segment (8-10mm) of the thoracic trachea from each rat and guinea pig was cut into equal swegments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force diplacement transducers under 0.5g loading tension. The dose of histamine (His) and acetylcholine (Ach) which evoked 50% of maximal response ($ED_{50}$) was obtained from cumulative dose response curves for histamine and acetylcholine($10^{-7}{\sim}10^{-4}M$). Contractions evoked by His ($ED_{50}$) and Ach ($ED_{50}$) were inhibited significantly by Chunggeumtang. In guinea pig tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $6.1%after\;30{\mu}l/ml$ Chunggeumtang, and 49.4% (p<0.01) after $100{\mu}l/ml$ Chunggeumtang. In rat tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was $6.7%\;after\;30{\mu}l/ml$ Chunggeumtang, and $54.2%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. Also, in guinea pig tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $30.6%\;(p<0.05)\;after\;30{\mu}l/ml$ Chunggeumtang, and $53.0%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. In rat tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was $24.1%\;(p<0.05)\;after\;30{\mu}l/ml$ Chunggeumtang, and $55.3%\;(p<0.01)\;after\;100{\mu}l/ml$ Chunggeumtang. Propranolol and indomethacin($10^{-7}M$) slightly but significantly attenuated the inhibitory effects of Chunggeumtang. Following treatment with propranolol, the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 27.6% in guinea pig induced by acetylcholine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 28.7% (p<0.05) in rat induced by acetylcholine contraction and the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 16.2% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 28.7% (p<0.05) in rat induced by histamine contraction. Indomethacin, the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 20.0% in guinea pig induced by acetylcholine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 16.9% (p<0.05) in rat induced by acetylcholine contraction and the mean percent inhibition caused by $100{\mu}l/ml$ Chunggeumtang fell to 16.4% in guinea pig induced by histamine contraction and by $100{\mu}l/ml$ Chunggeumtang fell to 23.1% (p<0.05) in rat induced by histamine contraction. Methylene blue($10^{-7}M$) did not significantly alter the inhibitory effect of Chunggeumtang. Also, I could find the effects of Chunggeumtang and Chunggeumtanggamorphine on the tracheal smooth muscle in guinea pig and rat did not change significantly. These results indicate that Chunggeumtang can relax histamine and acetylcholine-induced contraction of guinea pig and rat tracheal smooth muscle, and that this inhibition involves sympathetic effects and the release of cyclooxygenase products.

  • PDF

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF