Potential impact of metal crowns at varying distances from a carious lesion on its detection on cone-beam computed tomography scans with several protocols

  • Matheus Barros-Costa;Eduarda Helena Leandro Nascimento;Iago Filipe Correia-Dantas;Matheus L. Oliveira;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR(P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

Effects of various cone-beam computed tomography settings on the detection of recurrent caries under restorations in extracted primary teeth

  • Kamburoglu, Kivanc;Sonmez, Gul;Berktas, Zeynep Serap;Kurt, Hakan;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.109-115
    • /
    • 2017
  • Purpose: The aim of this study was to assess the ex vivo diagnostic ability of 9 different cone-beam computed tomography (CBCT) settings in the detection of recurrent caries under amalgam restorations in primary teeth. Materials and Methods: Fifty-two primary teeth were used. Twenty-six teeth had dentine caries and 26 teeth did not have dentine caries. Black class II cavities were prepared and restored with amalgam. In the 26 carious teeth, recurrent caries were left under restorations. The other 26 intact teeth that did not have caries served as controls. Teeth were imaged using a $100{\times}90-mm$ field of view and a 0.2-mm voxel size with 9 different CBCT settings. Four observers assessed the images using a 5-point scale. Kappa values were calculated to assess observer agreement. CBCT settings were compared with the gold standard using a receiver operating characteristic analysis. The area under the curve (AUC) values for each setting were compared using the chi-square test, with a significance level of ${\alpha}=.05$. Results: Intraobserver kappa values ranged from 0.366 to 0.664 for observer 1, from 0.311 to 0.447 for observer 2, from 0.597 to 1.000 for observer 3, and from 0.869 to 1 for observer 4. Furthermore, interobserver kappa values among the observers ranged from 0.133 to 0.814 for the first reading and from 0.197 to 0.805 for the second reading. The highest AUC values were found for setting 5 (0.5916) and setting 3 (0.5886), and were not found to be statistically significant(P>.05). Conclusion: Variations in tube voltage and tube current did not affect the detection of recurrent caries under amalgam restorations in primary teeth.

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries (CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구)

  • Lee Wan;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF

Preconcentration of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with Na-DDTC and Determination by Electrothermal Atomic Absorption Spectrometry (ET-AAS) (Na-DDTC로 흐림점 추출을 사용한 물시료에서 초미량 비스머스의 예비농축)

  • Moghimi, Ali
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.2
    • /
    • pp.140-147
    • /
    • 2008
  • .A new approach for a cloud point extraction-electrothermal atomic absorption spectrometric method was used for determining bismuth. The aqueous analyte was acidified with sulfuric acid (pH 3.0-3.5). Triton X-114 was added as a surfactant and natriumdiethyldithiocarbaminat (Na-DDTC) was used as a complexing agent. After phase separation at 50oC based on the cloud point separation of the mixture, the surfactant-rich phasen was diluted using tetrahydrofuran (THF). Twenty microliters (20 L) of the enriched solution and 10 l of 0.1% (w/v) Pd(NO3)2 as chemical modifier were dispersed into the graphite tube and the analyte determined by electrothermal atomic absorption spectrometry. After optimizing extraction conditions and instrumental parameters, a preconcentration factor of 195 was obtained for a sample of only 10 mL. The detection limit was 0.04 ng ml-1 and the analytical curve was linear for the concentration range of 0.04-0.70 ng mL-1. Relative standard deviations were <5%. The method was successfully applied for the extraction and determination of bismuth in water samples.

Development of Nutrition Screening Index for Hospitalized Patients (입원 환자 영양검색 지표 개발)

  • Kim, Su-An;Kim, So-Yeon;Sohn, Cheong-Min
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.6
    • /
    • pp.779-784
    • /
    • 2006
  • Several studies about hospital malnutrition have been reported that about more than 40% of hospitalized patients are having nutritional risk factors and hospital malnutrition presents a high prevalence. People in a more severe nutritional status ended up with a longer length of hospital stay and higher hospital cost. Nutrition screening tools identify individuals who are malnourished or at risk of becoming malnourished and who may benefit from nutritional support. For the early detection and treatment of malnourished hospital patients , few valid screening instruments fur Koreans exist. Therefore, the aim of this study was to develop a simple, reliable and valid malnutrition screening tool that could be used at hospital admission to identify adult patients at risk of malnutrition using medical electrical record data. Two hundred and one patients of the university affiliated medical center were assessed on nutritional status and classified as well nourished, moderately or severely malnourished by a Patient-Generated subjective global assessment (PG-SGA) being chosen as the 'gold standard' for defining malnutrition. The combination of nutrition screening questions with the highest sensitivity and specificity at prediction PG-SGA was termed the nutrition screening index (NSI). Odd ratio, and binary logistic regression were used to predict the best nutritional status predictors. Based on regression coefficient score, albumin less than 3.5 g/dl, body mass index (BMI) less than $18.5kg/m^2$, total lymphocyte count less than 900 and age over 65 were determined as the best set of NSI. By using best nutritional predictors receiver operating characteristic curve with the area under the curve, sensitivity and 1-specificity were analyzed to determine the best optimal cut-off point to decide normal or abnormal in nutritional status. Therefore simple and beneficial NSI was developed for identifying patients with severe malnutrition. Using NSI, nutritional information of the severe malnutrition patient should be shared with physicians and they should be cared for by clinical dietitians to improve their nutritional status.

Peptide Nucleic Acid Probe-Based Analysis as a New Detection Method for Clarithromycin Resistance in Helicobacter pylori

  • Jung, Da Hyun;Kim, Jie-Hyun;Jeong, Su Jin;Park, Soon Young;Kang, Il-Mo;Lee, Kyoung Hwa;Song, Young Goo
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.641-647
    • /
    • 2018
  • Background/Aims: Helicobacter pylori eradication rates are decreasing because of increases in clarithromycin resistance. Thus, finding an easy and accurate method of detecting clarithromycin resistance is important. Methods: We evaluated 70 H. pylori isolates from Korean patients. Dual-labeled peptide nucleic acid (PNA) probes were designed to detect resistance associated with point mutations in 23S ribosomal ribonucleic acid gene domain V (A2142G, A2143G, and T2182C). Data were analyzed by probe-based fluorescence melting curve analysis based on probe-target dissociation temperatures and compared with Sanger sequencing. Results: Among 70 H. pylori isolates, 0, 16, and 58 isolates contained A2142G, A2143G, and T2182C mutations, respectively. PNA probe-based analysis exhibited 100.0% positive predictive values for A2142G and A2143G and a 98.3% positive predictive value for T2182C. PNA probe-based analysis results correlated with 98.6% of Sanger sequencing results (${\kappa}$-value=0.990; standard error, 0.010). Conclusions: H. pylori clarithromycin resistance can be easily and accurately assessed by dual-labeled PNA probe-based melting curve analysis if probes are used based on the appropriate resistance-related mutations. This method is fast, simple, accurate, and adaptable for clinical samples. It may help clinicians choose a precise eradication regimen.

The cutoff criterion and the accuracy of the polygraph test for crime investigation (범죄수사를 위한 거짓말탐지 검사(polygraph test)의 판정기준과 정확성)

  • Yu Hwa Han ;Kwangbai Park
    • Korean Journal of Culture and Social Issue
    • /
    • v.14 no.4
    • /
    • pp.103-117
    • /
    • 2008
  • The polygraph test administered by the Korean Prosecutors Office for crime investigations customarily uses the score of -12 as the cutoff point separating the subjects who lie from those who tell the truth. The criterion used by the KPO is different from the one (-13) suggested by Backster (1963) who invented the particular method for lie detection. Based on the signal detection theory applied to the real polygraph test data obtained from real crime suspects by the KPO, the present study identified the score of -8 as an optimal criterion resulting in the highest overall accuracy of the polygraph test. The classification of the subjects with the score of -8 as the criterion resulted in the highest accuracy (83.17%) compared with the accuracies of classifications with the Backster's criterion (76.24%) and the KPO's criterion (80.20%). However, the new criterion was also found to result in more false-positive cases. Based on the results from the present study, it was recommended to use the score of -8 as the criterion when the overall accuracy is important but the score of -12 or -13 when avoiding false-positive is more important than securing the overall accuracy.

  • PDF

Development of Algorithms for Extracting Thermocline Parameters in the South Sea of Korea (한국 남부해역의 수온약층 추출 알고리즘 개발)

  • Yoon, Dong-Young;Choi, Hyun-Woo
    • Ocean and Polar Research
    • /
    • v.34 no.2
    • /
    • pp.265-273
    • /
    • 2012
  • A new algorithm was developed, not only to detect the existence of a thermocline, but also to extract the thermocline parameters (such as thermocline thickness, mixed layer thickness, maximum temperature gradient, and temperature difference of thermocline), using the vertical profile of water temperature. According to Kappa analysis, in order to find adequate threshold values of vertical water temperature gradients ${\Delta}T$ ($^{\circ}C/m$), agreement and reliability were 87% and 0.74 respectively, in the conditions of maximum ${\Delta}T{\geq}0.5$ and surface and bottom layers ${\Delta}T<{\mid}0.2{\mid}$. Also, three different kinds of methods, viz. 1. Gradient method, 2. Hyperbolic tangent method, and 3. Differential hyperbolic tangent method, were tested to extract the key parameters of a thermocline. Comparing the results of three different methods, the differential hyperbolic tangent method was the most appropriate to extract the start and end point of a thermocline curve.

Enhanced Simulated Annealing-based Global MPPT for Different PV Systems in Mismatched Conditions

  • Wang, Feng;Zhu, Tianhua;Zhuo, Fang;Yi, Hao;Fan, Yusen
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1327-1337
    • /
    • 2017
  • Photovoltaic (PV) systems are influenced by disproportionate impacts on energy production caused by frequent mismatch cases. The occurrence of multiple maximum power points (MPPs) adds complexity to the tracking process in various PV systems. However, current maximum-power point tracking (MPPT) techniques exhibit limited performance. This paper introduces an enhanced simulated annealing (ESA)-based GMPPT technique against multiple MPP issues in P-V curve with different PV system structures. The proposed technique not only distinguishes global and local MPPs but also performs rapid convergence speed and high tracking accuracy of irradiance changing and restart capability detection. Moreover, the proposed global maximum power tracking algorithm can be applied in the central converter of DMPPT and hybrid PV system to meet various application scenarios. Its effectiveness is verified by simulation and test results.