• 제목/요약/키워드: current waveform estimation

검색결과 34건 처리시간 0.044초

Open and Short Circuit Switches Fault Detection of Voltage Source Inverter Using Spectrogram

  • Ahmad, N.S.;Abdullah, A.R.;Bahari, N.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.190-199
    • /
    • 2014
  • In the last years, fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. The fault problem can cause equipment failure, data and economical losses. And the analyze system require to ensure fault problem and also rectify failures. The current errors on these faults are applied for identified type of faults. This paper presents technique to detection and identification faults in three-phase voltage source inverter (VSI) by using time-frequency distribution (TFD). TFD capable represent time frequency representation (TFR) in temporal and spectral information. Based on TFR, signal parameters are calculated such as instantaneous average current, instantaneous root mean square current, instantaneous fundamental root mean square current and, instantaneous total current waveform distortion. From on results, the detection of VSI faults could be determined based on characteristic of parameter estimation. And also concluded that the fault detection is capable of identifying the type of inverter fault and can reduce cost maintenance.

단일 전력단 능동 클램프형 고주파 공진 인버터의 특성 평가 (Characteristic Estimation of Single-Stage Active-Clamp Type High Frequency Resonant Inverter)

  • 원재선;강진욱;김동희
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권2호
    • /
    • pp.114-122
    • /
    • 2004
  • This paper presents a novel single-stage active-clamp type high frequency resonant inverter. The proposed topology is integrated full-bridge boost rectifier as power factor corrector and active-clamp type high frequency resonant inverter into a single-stage. The input stage of the full-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. By adding additional active-clamp circuit to conventional class-E high frequency resonant inverter, main switch of inverter part operates not only at Zero-Voltage-Switching mode but also reduces the switching voltage stress of main switch. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics estimation through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in the fields of induction heating applications, fluorescent lamp and DC-DC converter etc.

GMA용접의 단락이행영역에 있어서 아크 상태 평가를 위한 모델 개발 (Development of the Index for Estimating the Arc Status in the Short-circuiting Transfer Region of GMA Welding)

  • 강문진;이세헌;엄기원
    • Journal of Welding and Joining
    • /
    • 제17권4호
    • /
    • pp.85-92
    • /
    • 1999
  • In GMAW, the spatter is generated because of the variation of the arc state. If the arc state is quantitatively assessed, the control method to make the spatter be reduced is able to develop. This study was attempted to develop the optimal model that could estimate the arc state quantitatively. To do this, the generated spatters was captured under the limited welding conditions, and the waveforms of the arc voltage and of the welding current were collected. From the collected waveforms, the waveform factors and their standard deviations were produced, and the linear and non-linear regression models constituted using the factors and their standard deviations are proposed to estimate the arc state. the performance test to the proposed models was practiced. Obtained results are as follow. From the results of correlation analysis between the factors and the amount of the generated spatters, the standard deviations of the waveform factors have more the multiple regression coefficients than the waveform factors. Because the correlation coefficient between T and {TEX}$T_{a}${/TEX}, and s[T] and s[{TEX}$T_{a}${/TEX}] was nearly one, it was found that these factors have the same effect to the spatter generation. In the regression models to estimate the arc state, it was fond that the linear and the non linear models were also consisted of similar factors. In addition, the linear regression model was assessed the optimal model for estimating the arc state because the variance of data was narrow and multiple regression coefficient was highest among the models. But in the welding conditions which the amount of the generated spatters were small, it was found that the non linear regression model had better the estimation performance for the spatter generation than the linear.

  • PDF

EEG신호를 이용한 뇌 신호원 국부화에 관한 연구 (Brain Source Localization using EEG Signals)

  • 정재철;송민;이희영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.133-136
    • /
    • 2002
  • EEG(Electroencephalography) is generated by electrical activity between neurons in cortical. Waveform of EEG is changed according to body and mental states. Therefore EEG is used to diagnosis of encephalophyma and epilepsy, etc. Also EEG is used to HCI(Human-Computer Interface). This paper describes estimation of orientation and location of dipole sources. The forward model is three-layer spherical head model and current dipole model. Using analytical solution, EEG is generated. Using MNLS(Minimum-Norm Least-Square) method, orientation and location of dipole moment is estimated.

  • PDF

저밀도 폴리에틸렌의 고전계 파형에 대한 필름 두께 의존성 (Film Thickness Dependence of Ac High Field for Low Density Polyethylene)

  • 최용성;위성동;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.45-49
    • /
    • 2008
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

저밀도 폴리에틸렌을 위한 고전계 파형의 필름 두께의존성에 관한 연구 동향 (A Research Trend on Film Thickness Dependence of Ac High Feld for Low Density Polyethylene)

  • 정성찬;노정현;이주홍;황종선;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1988-1989
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

ESAD의 기폭 파형 예측을 위한 측정기반 LEEFI 모델링 및 검증 (Measurement-based LEEFI Modeling and Experimental Verification for Predicting Firing Waveform of an ESAD)

  • 강형민;김정호;황석현;정명숙;조세영;손중탁
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.20-26
    • /
    • 2019
  • In this paper, we propose measurement based numerical resistivity model for low energy exploding foil initiator (LEEFI) of electronic safety and arming device(ESAD). A resistivity model describes a behavior of variable resistance in LEEFI by firing current. The previous resistivity model was based on high energy detonator applications as explosive bridge wire and exploding foil initiator. Therefore, to estimate the voltage, current, and burst time of LEEFI, a resistivity model suitable for LEEFI is needed. For the modeling of resistivity of LEEFI, we propose a specific action based equation which represents a behavior of LEEFI when firing current is applied. To verify the proposed model, we analyze a firing current transmission path to obtain parasitic impedance. We experimentally verify that the proposed resistivity model offers precise estimation for the behavior of variable resistance in LEEFI.

리니어펄스모터의 2상 구동드라이버 제작 및 평가 (Manufacture and Estimation of Two phase driver for Linear Pulse Motor)

  • 김동희;강건일;안재영;김광헌;임영철;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.69-71
    • /
    • 2007
  • Need correct analysis of thrust for control performance improvement of HB-LPM (Hybrid type Linear Pulse Motor). It is difficult to analyze HB-LPM's thrust. In this paper, HB-LPM's thrust is expressed to mathematical expression. And it is proved validity of this numerical formula by thrust measurement system. Two phase driver is composed. It is verified validity of numerical formula that measure waveform of electric current and voltage that is supplied in each phase. In this study, composed two phase drive driver, advantage of this IGBT element 6 by accumulated IPM module 1 Driver composition possible. That is, can economize 1 moule. In other words, Driver composition is available by IGBT or metal oxide semiconductor field effect transistor element 4. This is economical big gain.

  • PDF

하이브리드형 선형펄스모터의 2상 구동드라이버 제작 및 평가 (Two phase driver manufacture of Hybrid type Linear Pulse Motor and estimation)

  • 김동희;안재영;강건일;김광헌;임영철;박성준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.28-30
    • /
    • 2007
  • Need analysis of correct thrust for control performance improvement of HB-LPM (Hybrid type Linear Pulse Motor). It is difficult to analyze HB-LPM's thrust. In this paper, HB-LPM's thrust is expressed to mathematical expression. And it is proved validity of this numerical formula by thrust measurement system. Two phase driver is composed. It is verified validity of numerical formula that measure waveform of electric current and voltage that is supplied in each Phase. In this study, composed two phase drive driver, advantage of this IGBT element 6 by accumulated IPM module 1 Driver composition possible. That is, can economize 1 module. In other words, Driver composition is available by IGBT or metal oxide semiconductor field effect transistor element 4. This is economical big gains.

  • PDF

Correlation of Peak Time Shift in Blood Pressure Waveform and PPG Based on Compliance Change Analysis in RLC Windkessel Model

  • Choi, Wonsuk;Cho, Jin-Ho
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.529-537
    • /
    • 2017
  • We explored how changes in blood vessel compliance affected the systolic rise time (SRT) of the maximum blood pressure (BP) peak wave and the diastolic fall time (DFT) of the minimal BP peak wave, compared to photoplethysmograpic (PPG) parameters, using a two-compartment, second-order, arterial Windkessel model. We employed earlier two-compartment Windkessel models and the components thereof to construct equivalent blood vessel circuits, and reproduced BP waveforms using PSpice technology. The SRT and DFT values were obtained via circuit simulation, considering variations in compliance (the dominant influence on blood vessel parameters attributable to BP changes). And then performed regression analysis to identify how compliance affected the SRT and DFT. We compared the SRTs and DFTs of BP waves to the PPG values by reference to BP changes in each subject. We confirmed that the time-shift propensities of BP waves and the PPG data were highly consistent. However, the time shifts differed significantly among subjects. These simulation and experimental results allowed us to construct an initial trend curve of individual BP peak time (measured via wrist PPG evaluations at three arm positions) that facilitated accurate individual BP estimations.