• 제목/요약/키워드: current unbalance

Search Result 263, Processing Time 0.026 seconds

The Study on Current Characteristic according to Core Cutting Degree in Three-Phase Induction Motor with Rectangular Stator Core (사각 고정자 철심을 가지는 삼상 유도전동기의 고정자 철심 절단 각에 따른 전류 특성 연구)

  • Im, Jong-Bin;Kim, Seung-Joo;Kim, Kwang-Soo;Lee, Hyung-Woo;Kim, Sol;Lee, Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1649-1654
    • /
    • 2009
  • Induction motors widely use in industry because structure is simple and hard and cost is generally cheap and they are easy to control. In recently, because of saving steel, ventilation and benefit of frame fixing, rectangular core type induction motors use in industry more and more. This paper presents current characteristic according to stator core cutting degree in three-phase induction motor (IM) with rectangular stator core. According to stator cutting degree, magnetic saturation and paths of flux are changed. Because of these situations, phase currents are unbalance and are produced harmonic components and they cause decrease of efficiency. We analyze each $10^{\circ}$ from $0^{\circ}$ to $30^{\circ}$ using 2-D finite element analysis (FEA). Optimal stator cutting core degree selection supplies stable currents and efficiency improvement. In this paper, loss separation test was executed by IEEE Std. 112-98 Method B and we compare with the result of loss separation by Simulation using FEM and by Experiment.

  • PDF

Effect of Tooth Shape and Unbalanced M.M.F on Static Thrust Force Characteristics of Linear Pulse Motor (리니어 펄스 모터에서 치 형상과 기자력 불평형이 정추력 특성에 미치는 영향)

  • Lee, Dong-Ju;Lee, Eun-Ung;Kim, Seong-Heon;Kim, Seong-Jong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.131-137
    • /
    • 2000
  • 2 phase 8 pole HB-type(flat-type) Linear Pulse Motor can be used as the high precision position actuator because of its many advantages (simple control circuit, high stiffness characteristics, etc). Also, using the microstep drive, its noise and vibration can be reduced considerably and positional resolution may be increased further. But, $20^{\circ}$tapered tooth shape to reduce the normal force have an much effect on the static thrust force characteristics. And, because of hybrid-type LPM, interaction between the permanent magnet and the excitation current have an effect on the various characteristics of LPM. Hence, in this paper, the effect of tooth shape on static thrust force characteristics was analyzed using the air gap permeance by finite element method. For analyzing the effect of unbalance between the m.m.f of permanent magnet and the m.m.f of excitation current, unbalanced m.m.f coefficient $\sigma$ were introduced with the permenace matrix and switching matrix.

  • PDF

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

Development of Protection Device for Voltage Unbalance Faults using Three-Phase Neutral Voltage (삼상 중성점 전압을 이용한 전압불평형 사고 방지용 보호장치 개발)

  • Kwak, D.K.;Kim, D.S.;Kim, J.H.;Kim, S.C.;Jung, W.S.;Son, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.621-622
    • /
    • 2012
  • The thermal over-current relay or electronic motor protection relay is mostly used as the open-phase detection device of the three-phase motor or load. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for open-phase protection using semiconductor devices. Therefore, the proposed open-phase protection device enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight.

  • PDF

An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition (계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어)

  • Tae-Hyeon Park;Hag-Wone Kim;Kwan-Yuhl Cho;Joon-Ki Min;Won-Il Choi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

The Direction of Power Quality Analysis Technology (전기품질 진단기술의 방향)

  • Kang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.16-18
    • /
    • 2005
  • Becoming more and more diversified and complicated, power quality management has focused on the electricity-failure duration(including the numbers), the appropriate rate of voltage(average voltage during 30 minutes), the stability rate of frequency etc. as a basic goal value. And recently the focus is moving into the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, instantaneous electricity failure, flicker etc. by the development of electricity & electronics and communication equipments, which had not been so big problems before. This paper will address the flow of analysis technology and forecast the desirable direction of power quality analysis technology in the future.

  • PDF

Optimization of Delivery Route for Multi-Vehicle under Time Various and Unsymmetrical Forward and Backward Vehicle Moving Speed (왕복비대칭 차량이동속도 하에서의 복수차량 배송경로 최적화)

  • Park, Sungmee;Moon, Geeju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.4
    • /
    • pp.138-145
    • /
    • 2013
  • A sweep-based heuristic using common area is developed for multi-vehicle VRPs under time various and unsymmetric forward and backward vehicle moving speed. One depot and 2 delivery vehicle are assumed in this research to make the problem solving strategy simple. A common area is held to make adjustment of possible unbalance of between two vehicle delivery completion times. The 4 time zone heuristic is used to solve for efficient delivery route for each vehicle. The current size of common area needs to be studied for better results, but the suggested problem solving procedures can be expanded for any number of vehicles.

A Study On the Output Voltage and Power Factor of the Three-Phase Four Switches Z-Source PWM Rectifier (3상 4 스위치 Z-소스 PWM정류기의 출력전압과 역률에 관한 연구)

  • Qiu, Xiao-Dong;Eom, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.48-49
    • /
    • 2013
  • In this paper, the four switches three-phase Z-source rectifier is studied. The conventional three-phase four switches rectifier can only either perform buck or boost operation, distortion and unbalance of the input current are serious. Therefore, we proposed the four switches three-phase Z-source rectifier which can realize buck function simply by applying the Z-impedance network. We will verify characteristics of Z-network by the simulation and experiment.

  • PDF

Power Quality Compensating System Using Series Active Power Filter

  • Kwon Hyoung-Nam;Gho Jae-Sok;Choe Gyu-Ha;Kim Hong-Sung;Han Suk-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.606-610
    • /
    • 2001
  • Voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many systems. Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. In this paper, proposed power system using series active power filter is not only harmonic compensation but also harmonic isolation between supply and load, and voltage regulation and unbalance compensation. The effectiveness of the proposed system is verified through computer simulations and experiments

  • PDF

Parallel processing of an active filter and a UPS (능동필터 겸용 무정전 전원장치)

  • Kang, Yu-Ri;Kim, Won-Ho;Kim, Jong-Soo;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.550-552
    • /
    • 1994
  • Recently, various activ filters such as current type and voltage type have been proposed to suppress harmonics caused by nonlinear load due to the use of semiconductor switching devices. At the early stage, active filters are used only to suppress harmonics. However, it has been proposed that they offer more functions such as voltage regulations, improvements of power factor and 3 phase unbalance. This study presents a combined function of active filter and a UPSs with one power processing stage.

  • PDF