• 제목/요약/키워드: current unbalance

검색결과 263건 처리시간 0.024초

IPMSM의 선간단락고장에 따른 새로운 d -q 등가회로 (Simplified d -q Equivalent Circuit of IPMSM Considering Inter-Turn Fault State)

  • 강봉구;허진
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1355-1361
    • /
    • 2016
  • The inter-turn fault (ITF) causes the negative sequence components in the d -q voltage equation due to an increase in the unbalance of three-phase input currents. For this reason, d -q voltage equation become complicate as the voltage equation is classified into positive and negative components. In this study, we propose a simplified d -q equivalent circuit of an interior permanent magnet synchronous motor under ITF state. First, we proposed modeling method for d -q current based on the finite element method simulation results. Then, we developed the simplified d -q equivalent circuit by applying the proposed d -q current modeling.

자성유체를 이용한 스퀴즈 필름 댐퍼의 동특성 동정 (Identification of Dynamic property of Squeeze Film Damper Using Magnetic Fluid)

  • 안영공;하종용;김용한;안경관;양보석;삼하신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.227-230
    • /
    • 2005
  • The paper presents the identification of dynamic property of a rotor system with a squeeze film damper (SFD) using magnetic fluid. An electromagnet is installed in the inner damper of the SFD. The magnetic fluid is well known as a functional fluid. Its rheological property can be changed by controlling the applied current to the fluid and the fluid can be used as lubricant. Basically, the proposed SFD has the characteristics of a conventional SFD without an applied current, while the damping and stiffness properties change according to the variation of the applied electric current. Therefore, when the applied current is changed, the whirling vibration of the rotor system can be effectively reduced. The clustering-based hybrid evolutionary algorithm (CHEA) is used to identify linear stiffness and damping coefficients of the SFD based on measured unbalance responses.

  • PDF

3상 전류평형 제어기술 적용장치 개발 (A Development of 3 Phase Current Balance Control Unit)

  • 천영식;성형수;원학재;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1088-1090
    • /
    • 2001
  • In general, Power SCR(Silicon Controlled Rectifier) is most widely used in Power Plant as well as Industrial field. It has been controlled and operated according to its own control method. Especially, in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control unit is described, it gets over the past analog control system limit, uses DSP(Digital signal processor) had high speed response, controls SCR gate firing angle for 3 phase current balance.

  • PDF

순시전압 sag 및 고조파 전류 보상을 위한 공간벡터 검출법 기반의 3상 하이브리드 직렬형 능동전력필터 (The Space Vector Detection based Three-Phase Hybrid Series Active Power Filter for Compensating Dynamic Voltage Sag and Harmonic Current)

  • 양승환;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.303-310
    • /
    • 2004
  • 본 연구에서는 순시전압 sag 및 고조파 전류 보상을 위한 공간벡터 검출법을 기반으로 한 3상 하이브리드 직렬형 능동전력필터 시스템을 제안하고 있다. 순시전안 sag 및 고조파 전류를 검출하기 위한 공간벡터 검출법은 종전의 이론에 비해 곱셈 연산 과정을 감소할 수 있고 좌표 변환이 필요치 않기 때문에 간략화한 보상 알고리즘 구현이 가능하다. 본 연구의 타당성은 전력전자전용 시뮬레이터 PSIM에 의해 정상상태와 과도상태에서 입증하였다. 그 결과 3상 교류 전원 모두에 순간적인 전압 sag가 발생되거나, 임의의 상에 왜형 및 sag가 있는 경우, 전압 보상 및 고조파 전류 보상이 모두 가능함을 입증하였다.

CGL의 재료에 따른 청색 형광 Tandem OLED의 발광 특성 (Emission Characteristics of Blue Fluorescence Tandem OLED with Materials of CGL)

  • 곽태호;주성후
    • 한국표면공학회지
    • /
    • 제47권4호
    • /
    • pp.210-214
    • /
    • 2014
  • We investigated emission characteristics of tandem organic light emitting devices (OLEDs) with p-type materials as charge generation layer. The tandem OLEDs were fabricated by using $MoO_x$, $WO_x$, C60 and HATCN as p-type material or not using p-type material for charge generation. When HATCN was used as p-type material, it showed high current density at low applied voltage, but increase of efficiency was small because of charge unbalance in emitting layer. In case of tandem OLED not using p-type material, applied voltage increased remarkably because of difficulty of hole injection. In case of $MoO_x$, $WO_x$ or C60 as p-type material, current emission efficiency increased greatly. In particular, current emission efficiency of tandem OLED using $MoO_x$ as p-type material increased up to 3 times than current emission efficiency of single OLED. The Commission Internationale de l'Eclairage (CIE) 1931 color coordinates were changed by overlapping of 504 nm emission wavelength. As a result, emission efficiency of tandem OLED improved compared with single OLED, but driving voltage also increased by increase of organic layer thickness.

전류제어신호를 이용한 MPPT제어기에 대한 연구 (Study on MPPT control using current control signal)

  • 강태경;강주성;고강훈;권순걸;서기영;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.280-282
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current-Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF

Individual DC Voltage Balancing Method at Zero Current Mode for Cascaded H-bridge Based Static Synchronous Compensator

  • Yang, Zezhou;Sun, Jianjun;Li, Shangsheng;Liao, Zhiqiang;Zha, Xiaoming
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.240-249
    • /
    • 2018
  • Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the software-based individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. Field test in a 10kV STATCOM confirms the performance of the proposed method.

자성유체를 이용한 스퀴즈 필름 댐퍼의 동특성 분석 (Investigation of Dynamic Property of Squeeze Film Damper Using Magnetic Fluid)

  • 하종용;김용한;양보석;삼하신;안경관;안영공
    • 한국소음진동공학회논문집
    • /
    • 제15권11호
    • /
    • pp.1262-1267
    • /
    • 2005
  • The paper presents the identification of dynamic property of a rotor system with a squeeze film damper (SFD) using magnetic fluid. An electromagnet Is installed in the inner damper of the SFD. The magnetic fluid is well known as a functional fluid. Its rheological property can be changed by controlling the applied current to the fluid and the fluid can be used as lubricant. Basically, the proposed SFD has the characteristics of a conventional SFD without an applied current, while the damping and stiffness Properties change according to the variation of the applied electric current. Therefore, when the applied current is changed, the whirling vibration of the rotor system can be effectively reduced. The clustering-based hybrid evolutionary algorithm (CHEA) is used to identify linear stiffness and damping coefficients of the SFD based on measured unbalance responses.

납 축전지의 병렬운전시 부하분담률 개선 (Improved Load Sharing Rate in Paralleled Operated Lead Acid Batteries)

  • 반한식;최규하
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.34-42
    • /
    • 2001
  • 전지는 화학에너지를 기계적인 처리과정 없이 전기에너지로 직접 전환하는 장치이다. 부하전압과 부하전류의 용량에 따라 단위전지를 직.병렬 연결하여 사용하게 되며, 전지의 병렬운전은 단독운전 보다 전압강하를 더 천천히 발생시키므로 전압강하에 민감한 전력변환장치들의 효율에 밀접한 관계를 가지고 있다. 병렬운전의 필요성과 장점 때문에 대부분의 축전지를 사용하는 시스템은 병렬운전을 하고 있고, 반면에 선.구 축전지 사이에서 순환 전류가 흐르고, 자가방전이 일어나는 단점 또한 가지고 있다. 신 축전지에서 충.방전 전류가 과다하게 흐르는 불평형 현상과 이로 인해 축전지의 수명단축을 일으키게된다. 본 논문에서는 마이크로 프로세서를 사용하여 선.구 축전지 사이의 볼평형 전류를 검출하고 외부저항을 첨가시켜 내부저항의 차이에 대한 감소효과를 얻어 불평형 전류를 보상하였다. 이를 실험을 통해 구현하였다.

  • PDF

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.