• 제목/요약/키워드: current structure

검색결과 6,961건 처리시간 0.032초

Characteristics of the magnetic flux-offset type FCL by switching component

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.18-20
    • /
    • 2016
  • The study of superconducting fault current limiter (SFCL) is continuously being studied as a countermeasure for reducing fault-current in the power system. When the fault occurred in the power system, the fault-current was limited by the generated impedance of SFCLs. The operational characteristics of the flux-offset type SFCL according to turn ratios between the primary and the secondary winding of a reactor were compared in this study. We connected the secondary core to a superconductor and a SCR switch in series in the suggested structure. The fault current in the primary and the secondary winding of the reactor and the voltage of the superconductor on the secondary were measured and compared. The results showed that the fault current in the load line was the lowest and the voltage applied at both ends of the superconductor was also low when the secondary winding of the reactor had lower turn ratio than the primary. It was confirmed based on these results that the turn ratio of the secondary winding of the reactor must be designed to be lower than that of the primary winding to reduce the burden of the superconductor and to lower the fault current. Also, the suggested structure could increase the duration of the limited current by limiting the continuous current after the first half cycle from the fault with the fault current limiter.

새로운 이산시간 가변구조 제어방법을 이용한 CNC의 고성능 제어 (High Performance CNC Control Using a New Discrete-Time Variable Structure Control Method)

  • 오승현;김정호;조동일
    • 제어로봇시스템학회논문지
    • /
    • 제6권12호
    • /
    • pp.1053-1060
    • /
    • 2000
  • In this paper, a discrete-time variable structure control method using recursively defined switching function and a decoupled variable structure disturbance compensator is used to achieve high performance circular motion control of a CNC machining center. The discrete-time variable structure control with the decoupled disturbance compensator method developed in this paper uses a recursive switching function defined as the sum of the current tracking error vector and the previous value of the switching function multiplied by a positive constant less than one. This recursive switching function provides much improved performance compared to the method that uses a switching function defined only as a linear combination of the current tracking error. Enhancements in tracking performance are demonstrated in the circular motion control using a CNC milling machine.

  • PDF

시스템적 관점에서 본 국방정보관리 구조 모델에 관한 연구 (A Study on a Model of Defense Information Resource Management Structure from the Viewpoint of System's Approach)

  • 권문택
    • 한국국방경영분석학회지
    • /
    • 제24권2호
    • /
    • pp.17-29
    • /
    • 1998
  • This paper is to aimed to design a model of Korea defense information resource management structure from the viewpoint of system's approach, especially focusing on planning/programming procedures, organizational structure and business process re-engineering. The author analyzed current projects and plans on the field of Korea defense information systems, for finding what kinds of problems and why the problems occurred. The author concluded that many problems came from wrong approach of previous information resource management. Highlights of the proposed model are as follows: 1) Planning and programming structure must be considered as a major information resources and it must be managed as a key role through the whole system life cycle; 2) Organizational structure should be properly set up for managing and implementing information system projects; 3) Business process should also be analyzed thoroughly for re-engineering and innovating current inefficient organizational structure. These three additional viewpoints added to previous model for improving Korea defense information resource management.

  • PDF

Electrical Properties of Organic Materials as Low Dielectric Constant Materials

  • Oh Teresa;Kim Hong Bae;Kwon Hak Yong;Son Jae Gu
    • 반도체디스플레이기술학회지
    • /
    • 제4권3호
    • /
    • pp.5-9
    • /
    • 2005
  • The bonding structure of organic materials such as fluorinated amorphous carbon films was classified into two types due to the chemical shifts. The electrical properties of fluorinated amorphous carbon films also showed very different effect of two types notwithstanding a very little difference. Fluorinated amorphous carbon films with the cross-link break-age structure existed large leakage current resulting from effect of the electron tunneling. Increasing the cation due to the electron-deficient group increased the barrier height of the films with the cross-link amorphous structure, therefore the electric characteristic of the final materials with low dielectric constant was also improved. The lowest dielectric constant is 2.3 at the sample with the cross-link amorphous structure.

  • PDF

유체-구조 연성해석을 통한 삼각단면 형상의 비닐하우스에 관한 연구 (A study of the triangular cross section type greenhouse using fluid-structure interaction)

  • 이규한;김정재;김정주;이상준;하호진;강태원
    • 한국가시화정보학회지
    • /
    • 제17권2호
    • /
    • pp.17-24
    • /
    • 2019
  • The purpose of this study is to study the fluid-dynamic and structural characteristics of the conventional greenhouse and to find possible improvement on the current greenhouse. The greenhouse is required to have enough rigidity of the structure while the installation and reinforcement should be as easy as possible. In this study, the structural stability to the snow load was tested through the computational structure analysis based on the building structure standard, and the wind load was computed by computational fluid-structure interaction analysis. The current analysis can be used as a reference data for a new greenhouse and it will be economically viable by reducing installation and maintenance costs.

소스영역으로 오버랩된 게이트 길이 변화에 따른 터널 트랜지스터의 터널링 전류에 대한 연구 (Source-Overlapped Gate Length Effects at Tunneling current of Tunnel Field-Effect Transistor)

  • 이주찬;안태준;심언성;유윤섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.611-613
    • /
    • 2016
  • TCAD 시뮬레이션을 이용하여 소스영역으로 오버랩된(overlapped) 게이트를 가진 터널링 전계효과 트랜지스터(Tunnel Field-Effect Transistor; TFET)의 오버랩된 게이트 길이에 따른 터널링 전류 특성을 조사하였다. 터널링은 크게 라인터널링과 포인트 터널링으로 구분되는데, 라인터널링이 포인트터널링보다 subthreshold swing(SS), on-current에서 더 높은 성능을 보인다. 본 논문은 Silicon, Germanium, Si-Ge Hetero TFET구조에서 게이트 길이를 소스영역으로 오버랩될 경우에 포인트 터널링과 라인터널링의 효과를 조사해서 SS와 on-current에 최적합한 구조의 가이드라인을 제시한다.

  • PDF

Investigation of the Effective Range of Cathodic Protection for Concrete Pile Specimens Utilizing Zinc Mesh Anode

  • Duhyeong Lee;Jin-A Jeong
    • Corrosion Science and Technology
    • /
    • 제23권3호
    • /
    • pp.195-202
    • /
    • 2024
  • A zinc mesh sacrificial anode cathodic protection method is recently being developed to protect the reinforced concrete structure in a marine environment. However, comprehensive information regarding the cathodic protection technology applied to reinforced concrete test specimens utilizing zinc mesh sacrificial anodes remains limited. Particularly, no research has investigated the effective range of sacrificial anode cathodic protection in a reinforced concrete structure regarding the transmission of protection current from zinc mesh sacrificial anode to the reinforced concrete structure, particularly concerning effects of temperature variations. This study examined the distribution of potential and current using a long single rebar and several segment reinforcing bars inside a horizontal beam. Vertical pile specimens were applied with a zinc mesh sacrificial anode to simulate concrete bridges or harbor structures. To check the effect of cathodic protection, cathodic protection potential and current of the reinforced concrete specimens were measured and 100 mV depolarization criterion test was performed. It was confirmed that effect of cathodic protection varied depending on resistivity and temperature. The cathodic protection test of pile specimens revealed that the maximum reachable range of cathodic protection current was 10 cm from the waterline as observed in the experiment.

수중 천퇴 인근에 설치된 해양구조물에 작용하는 유체력 결정에 대한 고찰 (Evaluation of Fluid Forces Acting on Offshore Structures Placed in the Vicinity of Underwater Shoal)

  • 전인식;민인기;심재설
    • 한국해안해양공학회지
    • /
    • 제19권2호
    • /
    • pp.136-145
    • /
    • 2007
  • 파랑이 수중 천퇴부를 넘어 쇄파하는 경우 파고는 작게 형성되나 강한 이차적 흐름 (쇄파유도류)이 발생한다. 따라서, 임의의 해양구조물이 쇄파대에 위치할 경우에는 단순히 가시적인 파고에만 근거한 파력산정은 과소설계를 초래할 가능성이 있으며 구조물의 안정설계를 위해서는 쇄파유도류의 유속이 가미된 상태에서의 유체력을 정확히 산정하여 반영할 필요가 있다. 본 연구에서는 Boussinesq 방정식 모델을 이용하여 쇄파대내에서의 파고분포와 쇄파유도류를 계산하는 기법을 수립하였으며 과거에 수행하였던 이어도 해양과학기지의 수리모형실험 (1/120)의 모델영역에 적용하였다. 이 계산결과를 이용하여 모형구조물에 작용하는 유체력을 계산하고 수리모형실험 결과와 비교함으로써 쇄파유도류의 영향을 정량적으로 평가하였다.

더블 게이트 구조 적용에 따른 IGZO TFT 특성 분석 (Analysis of the Output Characteristics of IGZO TFT with Double Gate Structure)

  • 김지원;박기찬;김용상;전재홍
    • 한국전기전자재료학회논문지
    • /
    • 제33권4호
    • /
    • pp.281-285
    • /
    • 2020
  • Oxide semiconductor devices have become increasingly important because of their high mobility and good uniformity. The channel length of oxide semiconductor thin film transistors (TFTs) also shrinks as the display resolution increases. It is well known that reducing the channel length of a TFT is detrimental to the current saturation because of drain-induced barrier lowering, as well as the movement of the pinch-off point. In an organic light-emitting diode (OLED), the lack of current saturation in the driving TFT creates a major problem in the control of OLED current. To obtain improved current saturation in short channels, we fabricated indium gallium zinc oxide (IGZO) TFTs with single gate and double gate structures, and evaluated the electrical characteristics of both devices. For the double gate structure, we connected the bottom gate electrode to the source electrode, so that the electric potential of the bottom gate was fixed to that of the source. We denote the double gate structure with the bottom gate fixed at the source potential as the BGFP (bottom gate with fixed potential) structure. For the BGFP TFT, the current saturation, as determined by the output characteristics, is better than that of the conventional single gate TFT. This is because the change in the source side potential barrier by the drain field has been suppressed.

선박용 LED 등기구의 알루미늄 합금 방열판의 방열성능 향상을 위한 플라즈마 전해 산화의 공정변수 선정에 관한 연구 (Process Parameter Selection for Plasma Electrolytic Oxidation to Improve Heat Dissipation Performance of Aluminum Alloy Heat Sink for Shipboard LED Luminaries)

  • 이정형;정인교;한민수
    • 한국표면공학회지
    • /
    • 제51권6호
    • /
    • pp.415-420
    • /
    • 2018
  • The possibility of an improvement in heat dissipation performance of aluminum alloy heat sink for shipboard LED luminaries through plasma electrolytic oxidation (PEO) was investigated. Four different PEO coatings were produced on aluminum alloy 5052 in silicate based alkaline solution by varying current density ($50{\sim}200mA/cm^2$). On voltage-time response curves, three stages were clearly distinguished at all current densities, namely an initial linear increase, slowdown of increase rate, and steady state(constant voltage). It was found that the increase in current density caused the breakdown voltage to increase. Two different surface morphologies - coralline porous structure and pancake structure - were confirmed by SEM examination. The coralline porous structure was predominant in the coatings produced at lower current densities (50 and $100mA/cm^2$) while under high current densities(150 and $200mA/cm^2$) the pancake structure became dominant. The coating thickness was measured and found to be in a range between about $13{\mu}m$ and $44{\mu}m$, showing increasing thickness with increasing current density. As a result, $100mA/cm^2$ was proposed as an effective process parameter to improve the heat dissipation performance of aluminum alloy heat sink, which could lower the LED operating temperature by about 30%.