• Title/Summary/Keyword: current structure

Search Result 6,898, Processing Time 0.03 seconds

Structure and Vorticity of the Current Observed Across the Western Channel of the Korea Strait in September of 1987-1989

  • Byun, Sang-Kyung;Kaneko, Arata
    • Ocean and Polar Research
    • /
    • v.21 no.2
    • /
    • pp.99-108
    • /
    • 1999
  • With sectional data obtained in September of 1987, 1988 and 1989 by quadrireciprocal ADCP measurement and CTD cast, the current structure, volume transport and vorticity in the Western Channel of the Korea Strait were studied. The characteristics of Tsushima Current water persisted throughout the summer especially in the homogeneous water of temperature $14-16^{\circ}C$ located at the depth of 50-100m below seasonal termocline. Thickness and velocity of the homogeneous layer are about 10-170m and 20-60cm/s. and the relative vorticity for this layer is shown to be nearly constant and it is smaller than the planetary vorticity. Potential vorticity of $2.70-7.10{\times}10^{-6}m^{-1}s^{-1}$ is found to be dependent mainly on planetary rather than on the relative vorticities. The Tsushima Current water represented by the homogeneous layer R14-16^{\circ}C$ may keep the potential vorticity at the area of strong current in the Strait. The ADCP current structure is similar to geostrophic current and the core of the current with the speed of 30-50cm/s is situated in the middle layer over the deep trough. With large tidal fluctuation the volume transport has mean value of 1.17sv which was about 40% larger than that of geostrophic calculation.

  • PDF

LDO regulator with improved regulation characteristics using gate current sensing structure (게이트 전류 감지 구조를 이용한 향상된 레귤레이션 특성의 LDO regulator)

  • Jun-Mo Jung
    • Journal of IKEEE
    • /
    • v.27 no.3
    • /
    • pp.308-312
    • /
    • 2023
  • The gate current sensing structure was proposed to more effectively control the regulation of the output voltage when the LDO regulator occurs in an overshoot or undershoot situation. In a typical existing LDO regulator, the regulation voltage changes when the load current changes. However, the operation speed of the pass transistor can be further improved by supplying/discharging the gate terminal current in the pass transistor using a gate current sensing structure. The input voltage of the LDO regulator using the gate current sensing structure is 3.3 V to 4.5 V, the output voltage is 3 V, and the load current has a maximum value of 250 mA. As a result of the simulation, a voltage change value of about 12 mV was confirmed when the load current changed up to 250 mA.

Information Structure of Relative Clauses in English: a Flexible and Computationally Tractable Model

  • Song, Sanghoun
    • Language and Information
    • /
    • v.18 no.2
    • /
    • pp.1-29
    • /
    • 2014
  • Relativization is one of the common syntactic operations to merge two different clauses into a single information unit. This operation plays a pivotal role to structuralize multiple clauses cohesively as well as serves to specify the property an individual has within the context. That implies that relativization contributes to information structure of multiclausal sentences. In this context, this paper delves into information structure of relative clauses in English with an eye toward creation of a computational model from a standpoint of machine translation. The current work employs Head-driven Phrase Structure Grammar (HPSG, Pollard and Sag (1994)) as a theory of grammar and Minimal Recursion Semantics (MRS, Copestake et al. (2005) as a meaning representation system. Building upon these formalisms, this paper addresses how information structure of relative clauses can be represented and constrained. The current work makes use of Individual CONStraints (ICONS) for modeling relative clauses with respect to information structure. The current work also investigates which relative clause involves which information structure constraint. The present study argues that non-restrictive relative clauses impose a more specific constraint on information structure than restrictive relative clauses.

  • PDF

The Heating Characteristics of Electric Bare Wire Melted by AC Current (AC 전류에 의해 용융된 나전선의 발열 특성)

  • Shong, Kil-Mok;Choi, Chung-Seog;Kim, Hyong-Kon;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.77-84
    • /
    • 2006
  • For a fire cause judgement this paper describes the heating characteristics of electric bare wire melted by AC current. The cower wires prepared for the experiment were 1.2[mm], 1.6[mm], and 2.0[mm] in diameter. Through the cross section analysis(CSA), it was confirmed that the dendrite structure grew at the angle of about 40[$^{\circ}$] or 60[$^{\circ}$] when the fusing current was applied to the wires. The larger the fusing current is, the more decreased the growth angle of the dendrite structure is. It was confirmed that the dendrite structure was arranged like the columnar structure.

The Electrical Properties of Single-silicon TFT Structure with Symmetric Dual-Gate for kink effect suppression

  • Lee, Deok-Jin;Kang, Ey-Goo
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.5
    • /
    • pp.783-790
    • /
    • 2005
  • In this paper, we have simulated a Symmetric Dual-gate Single-Si TFT which has three split floating n+ zones. This structure reduces the kink-effect drastically and improves the on-current. Due to the separated floating n+ zones, the transistor channel region is split into four zones with different lengths defined by a floating n+ region, This structure allows an effective reduction of the kink-effect depending on the length of two sub-channels. The on-current of the proposed dual-gate structure is 0.9mA while that of the conventional dual-gate structure is 0.5mA at a 12V drain voltage and a 7V gate voltage. This result shows a 80% enhancement in on-current. Moreover we observed the reduction of electric field in the channel region compared to conventional single-gate TFT and the reduction of the output conductance in the saturation region. In addition, we also confirmed the reduction of hole concentration in the channel region so that the kink-effect reduces effectively.

  • PDF

A Study on the Thermal Fields Control using a Floating-type Current Control Structure (부유식 해수유동제어구조물의 유동제어 특성에 대한 연구)

  • Boo, Sung-Youn
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.147-158
    • /
    • 1999
  • Warm or waste water discharged from offshore-based facilities often causes environmental polution as it is transported to coastal area due to tidal actions. In this research a floating-type current control structure is introduced in order to reduce the pollutant spreading in the coastal area. Effectivenss of the structure is investigated through the numerical experiment which is based on a 3-D finite difference multi-level scheme. The warm-water spreading in the bay is reduced when the draft of the structure increases and its optimum draft is found to be between 0.25h and 0.65h, where h is the water depth. The proposed structure is also tested in the Gohyun Bay and it ts proven to be applied to controllling pollutant spreading if its draft is properly chosen.

  • PDF

Study on Current and Water Quality Characteristics in Yongil Bay (영일만내의 유동과 수질특성에 관한 연구)

  • 김헌덕;김종인;류청로
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.246-252
    • /
    • 2000
  • The water quality in Yeongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex The study aims to simulate the current system that is necessary to built ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D baroclinic model considered tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most appliable on the Yongil Bay where current flows slowly and the flow direction is varied by depths. From the results of simulation considered tidal current only, It am be clearly said the water in Yongil Bay flows in through the surface layer and flows out through the bottom layer. And the fresh water from the Hyongsan river and the heated discharge from POSCO have little effect on the current structure in Yonggil Bay, but have and important effect upon the density structure by diffusion of heat and salt. And the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system.

  • PDF

The effect of field-line twist on the dynamic and electric current structures of emerging magnetic field on the Sun

  • An, Jun-Mo;Lee, Hwan-Hee;Kang, Ji-Hye;Magara, Tetsuya
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.102.1-102.1
    • /
    • 2011
  • In this study we use three-dimensional magnetohydrodynamic simulations to investigate how the dynamic state of emerging magnetic field is related to the twist of field lines. Emerging magnetic field forms a magnetic structure on the Sun where various kinds of activity such as solar flares, jets, and coronal mass ejections are observed. To understand the physical mechanism for producing such activity, we have to know the dynamic nature of this structure. Since flares are the manifestation of rapidly dissipating electric current in the corona, we also investigate the distribution of current density inside the structure and examine how it depends on the field-line twist. To demonstrate the dynamic structure of emerging magnetic field, we focus on the factors characterizing the geometric property and stratification of emerging magnetic field, such as the curvature of field line and the scale height of field strength. These two factors show that emerging field forms a two-part structure in which the central part is close to a force-free state while the outer marginal part is in a fairly dynamic state where magnetic pressure force is dominant. We discuss how the field-line twist affects the two-part structure and also explain a possible relation between electric current structure and sigmoid observed in a preflare phase.

  • PDF

Loop Current Calculation based on Voltage Angle Difference at Tie Switch for Switching Plan Validation in Distribution System Operation (상시개방점 양단전압 측정값을 이용한 배전선로 루프운전 가능 여부 판단 방법)

  • Son, Juhwan;Lim, Seongil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.14-21
    • /
    • 2015
  • Distribution systems are operated in radial structure, but temporal loop structure could be founded the live load transfer. Main purposes of reconfiguration of distribution network are load balancing, loss minimization and voltage drop maintaining. In the loop structure, huge loop current can be flowed between two substations in case of large voltage angle difference. Protection devices of distribution line can be triped by this huge loop current. So, precise calculation of loop current is very important for secure switching. This paper proposes a novel calculation method of loop current using the voltage angle differences measured at the tie switches. Feasibility of the propose method has been verified by various case studies based on Matlab simulation.

Analysis on the Structure Variation of IV Transformed by the Overload (과부하에 의해 변형된 비닐절연전선의 구조변화 분석)

  • 최충석;김형래;송길목;김향곤;김동욱;김동우
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.398-401
    • /
    • 2002
  • When the current flows over the allowable current due to the overload, it causes electric disaster such as an electrical fire and an electric shock by short current or leakage of electricity because the covering is deteriorated according to the heating action. In this paper, for the wire(IV 1.6mm) used as interior wiring, we analyzed a variation of the surroundings temperature, the form and the structure of a covering, and the crystal structure of a conductor. In the result of this experiment, the surroundings temperature at the allowable current of 300% rose to about 47$^{\circ}C$, and it rose up to the maximum allowable temperature of the wire at 400%. Consequently, it was broken within one minute at 500%. In the analysis of a metallograph, the conductor broken by the over current showed the dendrite. These analyses result will be applied to judging the electrical fire.

  • PDF