• 제목/요약/키워드: current stimulation

검색결과 482건 처리시간 0.026초

국내 인·허가 온열의료기기 기술 현황 조사 및 분석 (The Current State of Intended Equipment for Heating in Medical Use Based on Domestic Licensed Medical Devices)

  • 임수란;박정환;박지연;김송이
    • Korean Journal of Acupuncture
    • /
    • 제40권4호
    • /
    • pp.156-168
    • /
    • 2023
  • Objectives : This study aimed to determine the status of thermal stimulation devices approved in Korea for medical applications over the past 10 years, and based on this, to obtain insight for future thermal treatment in Korean medical institutions. Methods : We searched the item classification list entitled "Regulations on Medical Device Items and Rating by Item" from the Ministry of Food and Drug Safety Notice No. 2021-24, 2021 (Enforced March 19, 2021; www.mfds.go.kr) for individually licensed heaters using the terms "heat" and "heating". Results : We identified 17 items of thermal stimulation product group, of which 1,308 devices were licensed by February 4, 2022, and 53.2% of them (n=696) were devices with valid permits for distribution in Korea. Among the licensed devices, heating pad systems under/overlay (electric, home use) were approved the most, but combinational stimulator (for medical use, home use; Grade 2) accounted for the highest percentage among the current valid permission. Moxibustion apparatuses were licensed separately for electrical use and non-electrical use, and occupied a low percentage of the total devices. We analyzed 307 devices that were accompanied by technical documents and found that the heat sources were wires in 145 (47.2%), infrared rays in 44 (14.3%) and ultrasonic waves in 42 (13.7%) devices. Most (83.1%) devices were used for pain relief, while other applications included beauty, cancer treatment, maintenance of infant body temperature, and healing fractures. Conclusions : Thermal stimulation devices accounted for about 0.9% of all medical devices, and among them, combinational stimulators and heating pad systems under/overlay had the most valid permits. Thermal stimulation devices using heating wires and infrared rays were the most prevalent, and most were used to relieve pain. In order to develop a range of thermal stimulation devices that can be utilized in Korean medical institutions, it is imperative that they have potential applications beyond pain management, addressing various medical purposes. To achieve this, foundational research is necessary to effectively apply diverse heat sources based on medical objectives.

STS304 스테인리스 강선 호침에서 전침 자극 후 침체에 나타나는 전기적 부식 연구 (Electric Corrosion of STS304 Acupuncture Needles Used for Electroacupuncture)

  • 황혜숙;구성태;류연희;정상용;김유성;이지은;한경주;최선미
    • Journal of Acupuncture Research
    • /
    • 제24권5호
    • /
    • pp.105-111
    • /
    • 2007
  • Objectives : The electroacupuncture(EA) was often used in Oriental medicine clinic and basic researches. However, there have been neither any national standard of acupuncture needles in Korea nor many studies about the property of acupuncture needles for applying electrical stimulations. Therefore we investigated the electrical corrosion property of acupuncture needles used for EA stimulation in clinic. Methods : We observed the occurrence of electrical corrosion like changes in the surface of acupuncture needles after EA stimulation with various parameters(electrical stimulation intensity, treatment duration, diameter of needle) under a light microscope. We performed EA stimulation on Baekhoe($GV_{20}$) or Joksamli($ST_{36}$) of rats with intensity of 0.025, 0.05, 0.075, 0.1, 0.25 or 0.5mA at a 10Hz frequency. Results : The electrical corrosion-like changes were found on the surface of needles when the EA stimulation was given over 0.05mA of intensity. When electrical stimulation was treated for 10min, the electrical corrosion-like changes were low, but the electrical corrosion-like changes gradually increased by the treatment duration(20, 30min). We also found that acupuncture needles of 0.2mm diameter were produced more extensive electrical corrosion-like changes than acupuncture needles of 0.3 or 0.4mm diameter by electrical stimulation. Conclusions: These results suggested that EA stimulation could produce electrical corrosion-like changes of acupuncture needles through intensity of current, duration of electric stimulation and/or diameter of needle.

  • PDF

전기 자극이 치주인대세포와 치은섬유아세포에 미치는 영향 (Effect of the Electrical Stimulation on the Human Periodontal Ligament Cells and Gingival Fibroblasts)

  • 이욱;박준봉;이만섭;권영혁
    • Journal of Periodontal and Implant Science
    • /
    • 제29권4호
    • /
    • pp.821-838
    • /
    • 1999
  • On the basis of the evidences that electrical stimulation could enhance proliferation and differentiation of bone cells and promote healing and regeneration of bone, this study was performed to investigate the effects of electrical stimulation on human periodontal ligament cells and gingival fibroblasts in vitro, which also have important roles in regeneration of periodontium, and to evaluate the potential of clinical application of electrical stimulation. Human periodontal ligament cells and gingival fibroblasts were primarily cultured from the root surface of extracted premolar and the adjacent gingiva without periodontal diseases. In control group, the cells ($5{\times}10^4$ cells/ml)were incubated only in Dulbecco's Modified Eagle's Medium contained with 10% fetal bovine serum. In test groups, electrical stimulation was given at the current intensity of $0.25{\mu]A$(test group 1), $1.0{\mu}A$(test group 2), and $2.5{\mu}A$(test group 3) for 12 hours to the same culture media with the control group. After 12 hour exposure of electrical stimulation, the cells were incubated for 2 and a half days(60 hours), and then each group of cells was analyzed for cell proliferation, protein level, and activity of alkaline phosphatase. The results were as follows ; 1. The Rate of cell proliferation of every test group increased significantly in both periodontal ligament cells and gingival fibroblasts, and in periodontal ligament cells, test group 3 showed significantly increased proliferation compared to the other test groups(p<0.05). 2. In the protein levels, neither periodontal ligament cell nor gingival fibroblast showed statistically significant differences between control and test groups. 3. The activity of alkaline phosphatase in periodontal ligament cells increased significantly in all test groups(p<0.05), but there were no significant differences between 3 test groups. In gingival fibroblasts, the activity of alkaline phosphatase increased significantly only in test group 3(p<0.05). From the above results, it is concluded that electrical stimulation may have beneficial effects on the regeneration of destructed periodontal tissue in regard of the stimulation of periodontal ligament cells and gingival fibroblasts as well as electrically stimulated bone formation that has been known, and that electrical stimulation may have the potential of clinical application.

  • PDF

노년 여성의 신맥.조해 저주파 자극이 뇌파에 미치는 영향 (EEG Changes due to Low-Frequency Electrical Stimulation to the BL62 and KI6 of Elderly Women)

  • 이상훈;최광호;조성진;최선미;홍권의;류연희
    • Korean Journal of Acupuncture
    • /
    • 제30권2호
    • /
    • pp.135-142
    • /
    • 2013
  • 목적 : 본 연구는 노년층의 여성에게 신맥(BL62), 조해(KI6)혈에 대한 저주파자극이 뇌파에 어떠한 영향을 미치는지 알아보고 뇌 기능을 개선하는데 비화학적이고 비침습적인 자극 방법의 후보로써 가능성을 탐구해보고자 실시된 탐색적 연구이다. 방법 : 31명의 건강한 여성 피험자(평균연령, 54.5세)를 대상으로 이중맹검 무작위배정 임상연구가 12세션동안 실시되었다. 시험군에서는 감지할 수 없는 최대의 저주파자극이 실시되었으며(평균전류량, $0.04{\mu}A$), 대조군에서는 거짓자극이 실시되었다. 결과분석을 위해 12세션을 전후로 배경뇌파가 측정되었다. 결과 : 12세션의 자극이 실시된 후 대조군에 비해 실험군의 알파파 상대값은 11채널에서 유의한 증가를 보였으며(p<0.05), 감마파의 상대값은 7채널에서, 세타파의 상대값은 10채널에서 유의한 감소를 보였다. 결론 : 발목관절에 있는 신맥(BL62), 조해(KI6)혈에 대한 저주파 자극은 노년의 여성의 뇌에 베타, 세타, 감마파의 감소를 일으키는 반면 알파파를 선택적으로 증가시켜 뇌를 안정시키는 효과가 있는 것으로 보인다. 이러한 결과는 저주파자극이 향후 스트레스와 관련된 인지 문제를 치료하는 비침습적이고 비화학적인 도구로써의 가능성을 제공할 수 있을 것으로 보이며, 그 기전에 대한 추가적 연구가 필요할 것으로 보인다.

신경근전기자극 적용양식에 따른 대퇴사두근의 중앙주파수 변화 (Changes in Median Frequency of Quadriceps Muscle According to Application Modes of Neuromuscular Electrical Stimulation)

  • 최수희;오명화;김태열;정진규
    • 대한임상전기생리학회지
    • /
    • 제3권1호
    • /
    • pp.49-59
    • /
    • 2005
  • This study assigns each 8 of 24 normal persons to control group(Group I), strength increase group(Group II) and endurance increase group(Group III) to analyze differences in changes of strength and endurance with surface electromyography and kinetics according to application modes of neuromuscular electrical stimulation(NMES). Group I had not any treatment, group II performed 15 repeated contraction with 60% intensity of maximal voluntary isometric contraction(MVIC) by setting 10-sec on time and 50-sec off time and group III conducted 30 repeated contraction with 30% intensity of MVIC by setting 10-sec on time and 20-sec off time. For neuromuscular electrical stimulation, 2,500 Hz of Russian current, 35 pps of pulse rate and 200 of pulse width. Neuromuscular electrical stimulation was conducted by five times for total 4 weeks. Before and after experimentmotor unit action potential of vastus medialis, rectus femoris and vastus lateralis were measured with sEMG, median frequency(MDF) was analyzed, and thus the following results were obtained. There was significant difference in the period of measuring vastus medialis and rectus femoris in change of MDF and interaction among groups with analysis of surface electromyography before and after neuromuscular electrical stimulation(p<.001) and in particular, there was a remarkable change among groups according to the period of measurement. In conclusion, NMES influenced changes of strength and endurance according to its application modes and in particular, it was found that strength increment application had a significant influence on strength increment in applying short-time NMES.

  • PDF

Brief, Intense TENS 자극이 신경전도, 통증역치의 변화에 미치는 효과 (The effects of Breif, Intense Transecutaneous Electrical Nerve Stimulation on Nerve conduction, Pain Threshold in Healthy subjects)

  • 김태열;황태연;허춘복
    • The Journal of Korean Physical Therapy
    • /
    • 제6권1호
    • /
    • pp.171-183
    • /
    • 1994
  • Purphose. This present study examines the effect of brief, intense transcutaneous electrical nerve stimulation(BTENS) on sensory nerve conduction, electrical pain threshold, and two-point discrimination measured at the superficial radial nevre distribution in 20 healthy subjects. Subjects. Twenty volunteercs, (10 females and 10 males(age range : 20-38 years : $mean{\pm}SD\;:\;27.00{\pm}5.12$), only subjects without prior traumatological and pathological were eligible to participated in this study. Methods. Nerve conduction were determined for the right superficial radial nerve. Electrical pain threshold were determined for the right wrist ipsilateral to the site of BTENS. Small disc electrodes were attached to the surface of the skin stradding the end of the radius. Square wave electrical pulses were delivered from an isolated stimulator through a constant current device at a frequency of 2 Hz(5 ms pulse width). Two-point discrimination, measured on the sensory distribution of superficial radial nerve. BTENS was delivered using a Max-SD( Medical design co.) portable battery powered stimulator. A cicular Ag/AgCl electrode in contact with hypertonic saline gel was attached to the lateral(radial side) surface of the forearm. Results. No significant effects were observed between stimulation methods in the prestimulation cycle(multi-way ANOVA repeated measures : distal latency ; F1.14=0.332. amplitude ; F 0.80=0.445, pain threshold ; F0.06=0.940.2 point discrimination ; F1.50=0.236). Highly significant effects were observed time with the pretreatment and 6 posttreatment cycles(p<0.01). Mighty significants differences in nerve conduction and pain threshold were found using un multi-way ANOVA repeated measures among stimulation methods for each cycles(p<0.01). Conclusion and Discussion The authors concludes that both nerve conduction and pain threshold changes are associated with therapy (stimulation) level of BTENS.

  • PDF

표면근전도를 이용한 신경근 전기자극 치료변수에 따른 근피로도 분석 (Analysis of Surface EMG Power Spectrum and Muscle Fatigue Depending on the Variable of Neuromuscular Electrical Stimulation)

  • 김기원;김준선
    • The Journal of Korean Physical Therapy
    • /
    • 제26권5호
    • /
    • pp.280-289
    • /
    • 2014
  • Purpose: This study was conducted in order to determine the stimulation variables which should be considered when neuromuscular electrical stimulation (NMES) is applied for a muscle under the normal innervation to minimize muscle fatigue and increase force-generating ability. Methods: A total of 23 healthy men participated in the study and all subjects were randomly assigned to the 1:1 group, 1:3 group, 1:5 group, and control group with on-off ratio of NMES. The subjects performed a fatigue task, consisting of 10 times of isometric contraction sustained by NMES. NMES using Russian current stimulation was applied to muscle fatigue and divided into three sessions by pulse frequency (10 bps, 30 bps, 90 bps). The EMG was recorded using an MP 100 system from the quadriceps femoris muscle in four groups. Results: The differences of delta MdF and delta MF of between on-off ratio groups of 10 bps, 30 bps, and 90 bps pulse frequencies were very significant (p<0.05). According to the results of post hoc of 10, 90 bps, it was greater in the 1:1 group and the 1:3 group compared with the 1:5 group, and no fatigue was observed in the control group. In 30 bps, it was greater in the 1:1 group compared with 1:3, 1:5, and control group (p<.05). Conclusion: Among NMES variables to minimize muscle fatigue, the larger on-off ratio by pulse frequency showed the lower muscle fatigue. Therefore, on-off ratio needs to be great enough, and will be more efficient with the frequency 30 bps rather than of 10 bps and 90 bps.

촉각자극에 의한 자율신경계 및 뇌파 반응과 감성 (Emotional Preference Modulates Autonomic and Cortical Responses to Tactile Stimulation)

  • Estate Sokhadze;Lee, Kyung-Hwa;Imgap Yi;Park, Sehun;Sohn, Jin-Hun
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 추계학술발표 논문집
    • /
    • pp.225-229
    • /
    • 1998
  • The purpose of the current study was comparative analysis of autonomic and electrocortical responses to passive and active touch of the tektites with different subjective emotional preference. Perspective goal of the project is development of a template for classification of tactile stimuli according to subjective comfort and associated physiological manifestations. The study was carried out on 36 female college students. Physiological signals were acquired by Grass and B10PAC 100 systems with AcqKnowledge III software. Frontal, parietal and occipital EEG (relative power spectrum /percents/ of EEG bands - delta, theta, slow and fast alpha, low and fast beta), and autonomic variables, namely heart rate (HR), respiratory sinus arrhythmia (RSA), pulse transit time (PTT), respiration rate (RSP) and skin conductance parameters (SCL, amplitude, rise time and number of SCRs) were analyzed for rest baseline and stimulation conditions. Analysis of the overall pattern of reaction indicated that autonomic response to tactile stimulation was manifested in a form of moderate HR acceleration, RSP increase, RSA decrease (lowered vagal tone), decreased n and increased electrodermal activity (increased SCL, several SCRs) that reflects general sympathetic activation. Parietal EEG effects (on contra-lateral side to stimulated hand) were featured by short-term alpha-blocking, slightly reduced theta and significantly increased delta and enhanced fast beta activity with few variations across stimuli. The main finding of the study was that most and least preferred textures exhibited significant differences in autonomic (HR, RSP, PTT, SCR, and at less extent in RSA and SCL) and electrocortical responses (delta, slow and fast alpha, fast beta relative power). These differences were recorded both in passive and active stimulation modes, thus demonstrating reproducibility of distinction between most and least emotionally preferred tactile stimuli, suggesting influence of psychological factors, such as emotional property of stimulus, on physiological outcome. Nevertheless, development of sufficiently sensitive .and reliable template for classification of emotional responses to tactile stimulation based on physiological response pattern may require more extensive empirical database.

  • PDF

개에 있어서 침술에 의한 국소 및 전신마취에 관한 연구 (Induction of Local and General Analgesia by Electroacupuncture in Dogs)

  • 남치주;서강문
    • 한국임상수의학회지
    • /
    • 제14권2호
    • /
    • pp.244-253
    • /
    • 1997
  • This study was performed to evaluate the possibility of inducing analgesia by electroacupuncture stimulation at single acupoint or combined acupoints and to examine the analgesic effects following the combination of premedication and electroacupunrture analgesia(EA). Analgesia was induced by EA with the current of 1-4 volts and the frequency of 10-45 Hz to the acupoints Uown to be related to analgesia on the head/necIL axial part thoracic and pelvic limb. In Yi Feng acupoint of head/neck part pain responses were not disappeared after electroacupunrture stimulation to the head/necIL thoracic limbo thoraxl abdomen, loin, rear and pelvic limb. Pain responses were remained after EA of Tian Men-Tian Ping and Shen Yu arupoints of axial park whereas hypoalgesia was observed after EA of Tian Ping-Bai Hui acupoint in all parts of body. There was no analgesic effects after EA stimulation of the brachial plexus and Wai Kuan acupoint, whereas after EA stimulation of San Yang Lo, pain responses were disappeared in headfnecll, thoracic limb and pelvic limbo and in the other parts of body hypoalgesia was shown. In EA stimulation of Tsu San Li acupoint pain responses were disappeared in pelvic limb and in San Yin Chiao acupoint pain responses were disappeared in head/necIL thoracic and pelvic limb, and hypoalgesia was shown in abdomen. On the combination of San Yang Lo Pli Men) and San Yin Chiao (Pu Yan6 acupoints, pain response in heauneck was decreased in 5 minutes, whereas analgesia in thoracic and pelvic limb was induced after 20-30 minutes and in abdomen was noted after 50 minutes. The more frequrncy was increased, the more rapid analgesic e11%t was induced. The analgesic effects wert not good in laparotomy under EA at the combination of San Yang Lo (Xi Men) and San Yin Chiao (Pu Yang) arufoints. Enteroanastomosis could not be continued under acrpromazine, xylazine and diazepam with EA. However, under EA followed by tiletaminetzolazepam, the operation could be completed without additional anesthesia and the analgesic effects were good. There were no changes in clinical signs, hematological and serological values after combination of the premeditation of tiletamine+zolaEepam and EA. It is considered that EA alone is not suitable for the main surgery, but the combination method of EA and sedatives can be utilized in practice.

  • PDF

경두개직류전류자극 및 시지각 훈련 프로그램 적용이 치매환자의 시지각 기능 및 일상생활활동에 미치는 영향 (Does the Application Transcranial Direct Current Stimulation and Visual Perception Program Enhance the Visual Perception Function and ADL Performance of Dementia Patients)

  • 김고운;김보라;안태규
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.213-221
    • /
    • 2020
  • Purpose : This study aimed to evaluate the changes in visual perception and daily life activities after simultaneously applying the visual perception training program and transcranial DC stimulation. Particularly, this study tried to understand what changes in abilities among daily life activities influenced cognition. Methods : This study selected 50 dementia patients to achieve the objective. This study applied transcranial DC stimulation and a visual perception training program to a treatment group (n=25) and a visual perception training program to a control group (n=25). The intervention was applied five times per week and 30 minutes per session (total of 30 intervention sessions). This study measured visual perception functions and daily life activities using MVPT and FIM before and after applying the intervention. Results : The visual perception, mobility of daily life activities, cognition, and total score of the treatment group (n=25), which received the visual perception training program and transcranial DC at the same time, were significantly (p<.05) different between before and after the intervention. Moreover, when the visual perception and daily life activities of the treatment group and those of the control group after implementing the intervention were compared, they were significantly (p<.05) different between the two groups. Conclusion : The results of this study showed that the simultaneous application of the visual perception training program and transcranial DC stimulation was an effective means to enhance the visual perception and daily life activities of dementia patients. The results implied that transcranial DC stimulation, as well as the application of visual perception training program, as well as a visual perception training program, was effective for improving the visual perception functions and daily life activities dementia patients and simultaneous application of the two interventions would increase the effect even further.