• Title/Summary/Keyword: current state analysis

Search Result 1,826, Processing Time 0.025 seconds

A Discrete State-Space Control Scheme for Dynamic Voltage Restorers

  • Lei, He;Lin, Xin-Chun;Xue, Ming-Yu;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.400-408
    • /
    • 2013
  • This paper presents a discrete state-space controller using state feedback control and feed-forward decoupling to provide a desirable control bandwidth and control stability for dynamic voltage restorers (DVR). The paper initially discusses three typical applications of a DVR. The load-side capacitor DVR topology is preferred because of its better filtering capability. The proposed DVR controller offers almost full controllability because of the multi-feedback of state variables, including one-beat delay feedback. Feed-forward decoupling is usually employed to prevent disturbances of the load current and source voltage. Directly obtaining the feed-forward paths of the load current and source voltage in the discrete domain is a complicated process. Fortunately, the full feed-forward decoupling strategy can be easily applied to the discrete state-space controller by means of continuous transformation. Simulation and experimental results from a digital signal processor-based system are included to support theoretical analysis.

A Study on Strengthening Competitiveness of a State-owned Shipping Enterprise - A Case of Vinalines Corporation in Vietnam -

  • LE, Thanh-Van;Kim, Sung-June
    • Journal of Navigation and Port Research
    • /
    • v.40 no.5
    • /
    • pp.329-336
    • /
    • 2016
  • The overall purpose of this paper is to conduct research on alternatives for strengthening the competitiveness of a state-run shipping company, Vinalines Corporation, the largest shipping and maritime enterprise in Vietnam. The first section of the introduction gives a panoramic overview of the current development situation of the Vietnam maritime industry and Vinalines. After summarizing a literature review in section 2, some alternatives are proposed in sections 3 and 4 to overcome the current difficulties of Vinalines and to improve the corporation's competitiveness for sustainable development by utilizing linear optimization and financial analysis. The final section presents a summary and recommendation for future study. It is concluded that privatization is the key solution for every problem faced by the corporation at present. Furthermore, modification of laws, restructuring of enterprise governance, financial situation, and fleet are also extremely necessary.

A Study on the Problem of Permanent Magnet Linear Synchronous Motor According to End Effect (영구자석형 선형동기전동기의 단부효과에 의한 문제점 연구)

  • Kim, Duk-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.71-77
    • /
    • 2010
  • A discontinuity of magnetic circuits according to the end effect is generated in PMLSM. And magnetic state of the 3 phase coils becomes unbalanced. Due to the unbalanced magnetic state, the unbalanced flux linkage, back electro-magnetic force and inductance of the 3 phase coils appear. In result, the circulating current is generated by unbalanced inductance even if the input voltages are in balanced state. Then the thrust and efficiency are decreased because of the circulating current. Therefore, in this paper, the unbalanced inductance and the thrust reduction according to discontinuity of magnetic circuits are analyzed by FEA(2D). To demonstrate the validity of the analysis results, the experiment results are compared with analysis results.

A Study on the Impact of the Impedance Change of 345[kV] Power Transformers on Overall System Performance (345[kV] 전력용 변압기 %임피던스 변화에 따른 계통영향 분석)

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Song, Ji-Young;Kim, Tae-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.140-149
    • /
    • 2011
  • This paper deals with the impact analysis of the impedance change of 345/154[kV] power transformers on the KEPCO system's overall performance. Through the steady-state and dynamic analysis of power system, the maximum available impedance of power transformers were determined. Checking violation of short-circuit current ratings and transformer overload, parallel operation of power transformers, calculation of voltage variation ratio according to the impedance changes of power transformers are included in the steady-state analysis. In addition, transient and voltage stability analysis are also performed in the study. Available magnitudes to be able to change the impedance of the transformers in KEPCO system are finally determined in the paper.

The Effect of Transformer Leakage Inductance on the Steady State Performance of Push-pull based Converter with Continuous Current

  • Chen, Qian;Zheng, Trillion Q.;Li, Yan;Shao, Tiancong
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.349-361
    • /
    • 2013
  • As a result of the advantages such as high efficiency, continuous current and high stability margin, push-pull converter with continuous current (PPCWCC) is competitive for battery discharge regulator (BDR) which plays an important role in power conditioning unit (PCU). Leakage inductance yields current spike in low-ripple current of PPCWCCs. The operating modes are added due to leakage inductance. Therefore the steady state performance is affected, which is embodied in the spike of low-ripple current. PPCWCCs which are suitable for BDR can be separated into three types by current spike characteristics. Three representative topologies IIs1, IIcb2 and Is3 are analyzed in order to investigate the factors on the magnitude and duration of spike. Equivalent current sampling method (ECSM) which eliminates the sampling time delay and achieves excellent dynamic performance is adopted to prevent the spike disturbance on current sampling. However, ECSM reduces the sampling accuracy and telemetry accuracy due to neglecting the spike. In this paper, ECSM used in PPCWCCs is summarized. The current sampling error is analyzed in quality and quantity, which provides the foundation for offsetting and enhancing the telemetry accuracy. Finally, current sampling error rate of three topologies is compared by experiment results, which verify the theoretical analysis.

Analytical Solution of Magnetic Field in Permanent-Magnet Eddy-Current Couplings by Considering the Effects of Slots and Iron-Core Protrusions

  • Dai, Xin;Liang, Qinghua;Ren, Chao;Cao, Jiayong;Mo, Jinqiu;Wang, Shigang
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.273-283
    • /
    • 2015
  • In this study, we propose an analytical model for studying magnetic fields in radial-flux permanent-magnet eddy-current couplings by considering the effects of slots and iron-core protrusions on the eddy currents. We focus on the analytical prediction of the air-gap field by considering the influence of eddy currents induced in conducting bars. In the proposed model, the permanent magnet region is treated as the source of a time-varying magnetic field and the moving-conductor eddy current problem is solved based on the resolution of time-harmonic Helmholtz equations. The spatial harmonics in the air gap and in slots, as well as the time harmonics are all considered in the analytical calculation. Based on the proposed field model, the electromagnetic torque is computed by using the Maxwell stress tensor method. Nonlinear finite element analysis is performed to validate the analytical model. The proposed model can be used for permanent-magnet eddy-current couplings with any slot-pole combination.

A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter (고온초전도 한류기의 전력계통 적용에 관한 연구)

  • Bae, Hyeong-Thaek;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

A Study on the Current State and Policies for Standardization on Electronic Commerce (전자상거래 표준화 현황 및 정책 분석에 관한 연구)

  • 박윤정;임춘성;윤용기
    • Journal of Information Technology Applications and Management
    • /
    • v.10 no.3
    • /
    • pp.23-44
    • /
    • 2003
  • It is needed to search the electronic commerce standardization and to analysis its policies to meet the international situations strategically and forecast the technology surroundings for electronic commerce. This study aims at searching the current state of electronic commerce standardization and analyzing policies on electronic commerce by the driving subject, that is, government and private organization, major countries, and standard classifications of electronic commerce technologies such as e-documents, e-catalog, e-payment, and e-process. The government and private organizations get information for the current state and policies for standardization on electronic commerce and put them practical use to make policies and strategy applications.

  • PDF

A Sensorless PMSM Control Using the Separation of Two Voltage Source (이중전압원 분리를 이용한 PMSM의 센서리스 제어)

  • Jin-Woo Ahn;Sung-Jun Park;Dong-Hee Lee
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This paper presents a sensorless control strategy of a PMSM(Permanent Magnet Sycchoronous Motor). This method is very simple to compute the position angle of a rotor. A principle and a practical solution are described. A sensorless control algorithm is proposed to remove a mechanical position sensor. The theory is based on the superposition principle. The state equation of a motor is divided into two conditions: one is the state equation of exciting voltage and phase current in a constraint, the other is the state equation of back EMF(Electromotive Force) and phase current in a short circuit. Based on the analysis, short circuit current by back EMF is computed and then the information of position angle is calculated. The proposed method is verified by experimental results.

Study on Current State of the Art of Serviscape in Healthcare Sector (의료분야의 서비스케이프 연구동향에 관한 연구)

  • Lee, Chang Won;Kim, Hee Soo
    • Korea Journal of Hospital Management
    • /
    • no.spc
    • /
    • pp.14-24
    • /
    • 2016
  • This study is to present current research state of the art in serviscape and performance in healthcare system. Previous studies related to serviscape in healthcare sector are explored with limitations. This study conducts a content analysis with literature reviews in order to synthesize previous studies into three branch constitution dimension of the serviscape presenting the service environment. This study provides a current research state of the art and a future direction in serviscape in healthcare sector. Study results provide serviscape, customer response, satisfaction, and behavior intention in terms of healthcare settings. The patients and hospital customers as well as hospital employees should share the service experiences of the good quality in a proper service environment so that the patients and customer can satisfy and revisit the hospital.