• 제목/요약/키워드: current return path

검색결과 37건 처리시간 0.027초

병원 재무비율 지표들 간의 구조적인 관계 분석 (An Analysis of Structural Relationships among Financial Indicators of Hospitals in Korea: Applying Structural Equation Modeling(SEM))

  • 정민수;이건형;최만규
    • 보건행정학회지
    • /
    • 제18권2호
    • /
    • pp.19-38
    • /
    • 2008
  • Financial ratios are key indicators of an organization's financial and business conditions. Among various financial indicators, profitability, financial structure, financial activity and liquidity ratios are frequently used and analyzed. Using the structural equation modeling(SEM) technique, this study examines the structural causal relationships among key financial indicators. Data for this study are taken from complete financial statements from 142 hospitals that passed the standardization audit undertaken by the Korean Hospital Association from 1998 to 2001 for the purpose of accrediting teaching hospitals. In order to improve comparability, ratio values are standardized using the Blom's normal distribution. The final model of the SEM has four latent constructs: financial activity(total asset turnover, fixed asset turnover), liquidity(current ratio, quick ratio, collection period), financial structure(total debt to equity, long-term debt to equity, fixed assets to fund balance), and profitability(return on assets, normal profit to total assets, operating margin to gross revenue, normal profit to gross revenue). While examining several model fit indices(Chi-square (df) = 178.661 (40), likelihood ratio=4.467, RMR=.11, GFI=.849, RMSEA=.157), the final SEM we employed shows a relatively good fit. After examining the path coefficient of the constructs, the financial structure of the hospital affects the hospital's profitability in a statistically significant way. A hospital which utilizes its liabilities, more specifically fixed liabilities, and makes a stable investment decision for fixed assets was found to have a higher profitability than other hospitals. Then, the standard path coefficients were examined to directly compare the influence of variables. It was found that there were no statistically significant path coefficients among constructs. When it comes to variables, however, statistically significant relationships were found. between. financial activity and. fixed. asset turnover, and between profitability and normal profit to gross revenue. These results show that the observed variables of fixed asset turnover and normal profit to gross revenue can be used as indicators representing financial activity and profitability.

KTX산천 귀선전류고조파가 일반선 TI-21형 AF궤도회로에 미치는 영향분석 (Effect Analysis of Classical Line TI-21 type Audio Frequency Track Circuit from KTX Sancheon Return Current Harmonics)

  • 최재식;김희식;박주훈;김범곤
    • 한국철도학회논문집
    • /
    • 제19권1호
    • /
    • pp.38-45
    • /
    • 2016
  • KTX산천 고속차량에서 사용하는 전력변환시스템은 전력전자기술, 고속 대용량 반도체소자 및 마이크로프로세서의 기술발달에 힘입어 높은 성능과 효율, 안전성, 에너지 소비측면에서 뛰어난 제어능력을 갖추게 되었다. 하지만 고속스위칭소자인 IGBT를 사용함에 따라 발생하는 고조파로 인해 전기차량은 물론 변전소, 신호시스템, 데이터전송 및 감시시스템 등 선로변 신호설비에 문제를 야기시켰다. 특히 전력변환장치의 정수배 부근 주파수에서 발생하는 귀선전류고조파의 영향으로 TI-21 무절연AF궤도회로가 부정 동작하는 사례가 발생되었다. 본 논문은 고속전기차량과 궤도회로간 귀선전류고조파 이동경로 분석을 위하여 실제 현장에서 측정 및 분석방법을 제시하였다. 이러한 분석결과는 향후 신규로 도입되는 고속전기차량, AF궤도회로, 공동접지망 설계 시 폭넓게 반영될 것으로 기대된다.

직선과 원호가 결합된 WLAN/WiMAX용 삼중대역 안테나 설계 및 제작 (A Design and Manufacture of Triple Band Antenna with Line and Arc shaped Strips for WLAN/WiMAX system)

  • 권만재;윤중한
    • 한국전자통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.15-22
    • /
    • 2018
  • 본 논문에서는 WLAN/WiMAX 시스템에 적용 가능한 모노폴 안테나를 제안하였다. 제안된 안테나는 두 개의 원호와 한 개의 직선 선로로 설계하여 세 개의 전류흐름을 갖도록 구성하여 세 개 대역의 공진특성을 갖도록 설계하였다. 두 개의 원호 길이와 한 개의 직선 선로의 길이를 상호결합을 고려하려 본 논문에서 요구되는 특성을 얻기 위한 최적화 수치를 얻었다. 제안된 안테나는 $23.5mm(W1){\times}32.0mm(L1){\times}1.0mm(t)$의 유전율이 4.4인 RF-4 기판 위에 $21.0mm(W6){\times}31.0mm(L7)$의 크기로 제작되었다. 측정결과로부터, 927 MHz (1.844~2.771 GHz), 926 MHz (3.33~4.256 GHz), 그리고 1,415 MHz (5.13~6.545 GHz)의 대역폭을 얻었다. 또한 요구되는 삼중대역에서 측정된 이득과 방사패턴의 얻었다.

MBS의 발행구조, 가치평가 몇 투자자 특성에 관한 연구 (Effects of Security Design and Investor Utilities on the Valuation of Mortgage-Backed Securities)

  • 유진
    • 재무관리연구
    • /
    • 제22권1호
    • /
    • pp.147-179
    • /
    • 2005
  • 모기지유동화증권(Mortgage-Backed Securities : MBS)의 도입과 변화를 주도한 근본적인 원인은 투자자 혹은 차입자의 효용 제고 및 욕구 충족에 있다. 본 연구는 이러한 사실에 주목하여 MBS의 발행 구조에 따라 그 가치가 변동할 수 있음을 이론 모형으로 정립, 증명, 분석 및 해석한다. 구체적으로 자동이체증권과 PAC-Support CMO라는 차별적 발행구조의 두 MBS의 가치를 투자자의 효용의 관점에서 파악하고 발행구조에 따라 후자가 전자보다 더 큰 가치를 창출할 수 있음을 이론적으로 보인다. 한편 모기지 및 MBS의 가치평가에 재금융(refinancing)으로 인한 조기상환 위험의 평가가 매우 중요하며, 재금융은 이자율의 등락 및 과거 이자율의 경로에 의하여 크게 영향 받기 때문에 이를 3기간 모형으로 반영하여 MBS의 가치평가를 시도하였다. 특히 소진현상(burnout)을 모형에 명확히 반영하여 이 현상이 MBS의 현금흐름, 위험 및 가치에 미치는 영향을 고찰하였다. 본 연구 결과 동일한 현금흐름 및 위험을 제시하는 MBS보다 차별적으로 설계된 MBS가 선호될 수 있으며 후자의 가치를 극대화하는 최적의 발행 구조가 존재함이 인정된다.

  • PDF

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

배전선로에서의 조가선 차폐 효과 연구 (A Study on a Shielding Effect of the Messenger Wires in Distribution Lines)

  • 김인수;한웅;여상민;김철환;원봉주;임용훈
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

Iris 부착 3차원 선형편파 마이크로스트립 패치 안테나의 소형화에 관한 연구 (Study on the Miniaturization Method of a 3-dimensional Linear Polarization Microstrip Patch Antenna using the Irises)

  • 장연정;서정식;조중환;우종명
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.450-453
    • /
    • 2003
  • In this paper, the miniaturization of linear polarization microstrip patch antenna is studied by attached Irises near the square linear polarization microstrip patch antenna which are induced the increase of current path. Microstrip patch antenna having the Irises is designed and fabricated at the resonant frequency of 1.575 GHz. The result is like that the resonant length of patch is reduced 41.5 mm which correspond to 50.9 % of that of plane type(81.5mm). The return loss is -28.5 dBd and -10 dB bandwidth is 103 MHz( 6.5 %). And as the radiation pattern is broad through the size reduction of patch, the gain is 5.9 dBd and -3 dB beamwidth of E-plane is $111.9^{\circ}$.

  • PDF

X-Band 6-Bit Phase Shifter with Low RMS Phase and Amplitude Errors in 0.13-㎛ CMOS Technology

  • Han, Jang-Hoon;Kim, Jeong-Geun;Baek, Donghyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권4호
    • /
    • pp.511-519
    • /
    • 2016
  • This paper proposes a CMOS 6-bit phase shifter with low RMS phase and amplitude errors for an X-band phased array antenna. The phase shifter combines a switched-path topology for coarse phase states and a switch-filter topology for fine phase states. The coarse phase shifter is composed of phase shifting elements, single-pole double-throw (SPDT), and double-pole double-throw (DPDT) switches. The fine phase shifter uses a switched LC filter. The phase coverage is $354.35^{\circ}$ with an LSB of $5.625^{\circ}$. The RMS phase error is < $6^{\circ}$ and the RMS amplitude error is < 0.45 dB at 8-12 GHz. The measured insertion loss is < 15 dB, and the return losses for input and output are > 13 dB at 8-12 GHz. The input P1dB of the phase shifter achieves > 11 dBm at 8-12 GHz. The current consumption is zero with a 1.2-V supply voltage. The chip size is $1.46{\times}0.83mm^2$, including pads.

디지털 케이블 방송 환경에서 개인 미디어를 위한 스트리밍 프로토콜 연구 (A Research on Streaming Protocol for User-Created Contents in Digital Cable Broadcasting environment)

  • 김성원;김정환;시장현;정문열
    • 대한전자공학회논문지TC
    • /
    • 제44권1호
    • /
    • pp.54-61
    • /
    • 2007
  • 최근 인터넷에서 많은 관심을 보이고 있는 동영상 개인 미디어(UCC:User-Created Contents)를 영상 콘텐츠의 기본적인 매체라 할 수 있는 TV상에서 직접 즐길 수 있다면 관련 미디어의 대중적인 효과는 배가 될 것이다. 디지털 케이블 방송에서 UCC와 같은 다양하고 많은 미디어 콘텐츠를 서비스하고자 한다면 현재의 OCAP 표준 환경에서는 RVOD(Real Video on Demand)와 동일한 서비스 모델을 가져야 하는 부담과 UCC 제공을 위한 방송 플랫폼별 인터페이스가 필요할 것이다. 이러한 문제점을 보완하기 위해 Return Path기반으로 RTP(Real-time Transport Protocol)을 이용해 기존의 VOD방식의 스트림 대역에서 분리하고 별도의 네트워크 VOD 프로토콜을 구현하고자 한다. 이는 라이브 방송환경과 동일한 인프라의 지속적인 확장보다 기존의 네트워크 환경을 이용하여 VOD 서비스를 위한 인프라에 많은 영향을 받지 않는 서비스가 가능할 수 있도록 하는 것이다. 따라서 본 논문에서는 RTP 사용을 위해 셋톱박스상의 다운로드 가능한 구조의 클래스 분석과 디코딩을 위한 전송 스트리밍 서버 및 트랜스코딩 과정의 설계에 중점을 두고 서술한다. 경량화 된 VOD 서비스 환경을 설계함으로써 방송환경 하에서 주문형 서비스의 효율적인 확장성을 보장할 수 있는 기회를 가져올 수 있을 것으로 기대한다.

700 MHz 대역 LTE용 광대역 PIFA 설계 (A Design of Wide-Band PIFA for 700 MHz LTE Band)

  • 박찬진;민경식;김정원;안성용
    • 한국전자파학회논문지
    • /
    • 제23권3호
    • /
    • pp.328-334
    • /
    • 2012
  • 본 논문은 휴대폰용 700 MHz 대역 LTE용 안테나의 광대역 설계 기법을 제안한 것이다. 제안한 안테나는 역 F(Planar Inverted - F) 구조를 기본으로 설계되었다. 광대역을 실현하기 위해 전기적 길이를 제어하는 방법으로 라운드 구조와 이중 공진 특성을 얻을 수 있는 지선 소자가 설계에 도입되었다. 그 결과, 복소비 유전율이 4.4인 FR-4 기판에서 $30{\times}34mm$의 협소한 공간임에도 불구하고, 약 95 MHz의 대역폭을 실현했다. 측정된 반사손실, 대역폭과 이득 방사 패턴은 계산 값과 잘 일치하였다.