• 제목/요약/키워드: current phase

검색결과 5,401건 처리시간 0.034초

Active Disturbance Rejection Control for Single-Phase PWM Rectifier with Current Decoupling Control

  • Yan, Ruitao;Wang, Ping
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2354-2363
    • /
    • 2018
  • This paper proposed a novel double closed control strategy for single-phase voltage source pulse width modulation (PWM) rectifier based on active disturbance rejection control (ADRC) and dq current decoupling control. First, the mathematical model of the single-phase PWM rectifier in the d-q axis synchronous rotating reference frame is established by constructing a virtual component using a second-order generalized integrator (SOGI). Then, the mathematical model is simplified according to the active power conservation, and the first-order equation of single-phase PWM rectifier voltage outer loop is acquired. A linear auto-disturbance rejection controller is used to design the voltage outer loop according to the first-order equation. Finally, the proposed control strategy and the traditional PI control are compared and verified by simulation and physical experiments. Both simulation and experimental results confirm that the proposed control strategy has excellent dynamic performance and strong rejection ability to disturbances.

비접지 계통에서 영상전류 위상을 이용한 고장표시 생성 알고리즘 (A Fault Indicator Generation Algorithm using Phase Angle of Zero-Sequence Current in Ungrounded System)

  • 임희택;임일형;최면송;이승재
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1141-1149
    • /
    • 2008
  • Most faults are single-phase-to-ground fault in ungrounded system. The fault currents of single-phase-to-ground are much smaller than detection thresholds of measurement devices, so detecting single-phase-to-ground faults is difficult and important in ungrounded system. This paper proposed to a FI(Fault Indicator) generation algorithm in ungrounded system. The algorithm just using line-to-line voltage and zero-sequence current detects fault line, fault phase, fault section and FI(Fault Indicator) at terminal device, This paper also proposed to application plan for this algorithm. In the case study, the proposed algorithm has been testified in demo system by Matlab/Simulink simulations.

비접지 배전선로의 고장상 판별 알고리즘 개발 (A Faulted Phase Discrimination Algorithm in Ungrounded Distribution System)

  • 이덕수;임성일;최면송;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.114-120
    • /
    • 2003
  • According to the use of distribution automation systems, the function to find or to search a fault phase is necessary for automatic switches in a distribution substation. In this paper, two algorithms are developed to fine the fault circuit and the fault phase for the automatic switches in substation with ungrounded power system. One is the fault circuit searching method using the zero sequence voltage at the bus and zero sequence current of circuit current and the other is to find the fault phase using the line voltage and zero sequence current. The developed algorithms are tested in the case study simulations. An ungrounded power system is modeled by EMTP as a case study system. The developed algorithms are tested in the case study simulations and each shows correct results.

3상 4선식 부하설비의 전압, 전류 및 부하 불평형율 측정 분석 (The measurement & Analysis of Voltage, Current and Load Unbalance Factor at Three Phase Four Wire Load System)

  • 김종겸;박영진;이동주;이종한;정종호;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.28-30
    • /
    • 2005
  • This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. This system is composed of three one-phase transformer with each other capacity. Current unbalance factor is measured by the power quality measurement apparatus and compared by the load unbalance factor. Each phase has an impedance each other by the unbalanced load operation pattern and give rise to voltage unbalance.

  • PDF

세그먼트 극을 가진 BLDC 전동기의 가진력에 관한 연구 (Effects of Segmented Poles on Exciting Forces for BLDC Motors)

  • 김경태;황상문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.530-536
    • /
    • 1999
  • This paper investigates effects of segmented poles on exciting forces such as cogging torque, BEMF, phase current, torque ripple and local forces. Cogging torque, BEMF and local force are determined by FEM analysis and phase current is calculated using voltage equations after determining BEMF and phase inductance. Effective dead zones at pole separations result in wider than the physical dead zones due to leakage field during magnetization. Due to the existence of dead zones, there exist additional exciting harmonics of the cogging torque which play adverse effect on vibration and noise performance. The magnitude of BEMF is decreased and the waveforms are also distorted depending on dead zone positions. Segmented poles inevitably cause uneven magnetic field distribution at pole separations which introduces additional harmonics of exciting forces which are detrimental to structural to structural resonances. They also decrease motor efficiency by reducing effective phase BEMF.

  • PDF

설정치 변경에 의한 영상과전류계전기의 성능개선 (Developed Ability of Zero-phase Overcurrent Relay by Changed setting point value)

  • 김남호;윤달순;장성일;최정환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.220-222
    • /
    • 1998
  • This paper presents a method, which develops an ability of Zero-phase Overcurrent Relay. Zero-phase current is very useful factor of Fault decision in Protect Relaying system. Actually, the setting-point value of Designed Relay, using Zero-phase current, is fixed. So in the case of deciding fault, Fixed setting-point value is not suitable for changing Load. and cause errors in Distributions system. For solving this problem, This paper proposes the Changed setting point value Algorithm, which can be adaptive for changing Distributions system using Zero-phase current r.m.s. indexes. The results of simulation under Load changing and High impedance fault show that proposed algorithm is useful for changing Distributions system and decreasing errors.

  • PDF

상부전극에 따른 상변화 메모리의 발열 특성 (Thermal characteristic of PRAM with top electrode)

  • 최홍규;장낙원;김홍승;이성환;마석범
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.97-98
    • /
    • 2007
  • In this paper, we analyzed the reset current variation of PRAM device with top electrode using the 3-D finite element analysis tool. As thickness of phase change material thin film decreased, reset current caused by phase transition highly increased. Joule's heat which was generated at the contact surface of phase change material and bottom electrode of PRAM was given off through top electrode to which was transferred phase change material. As thermal conductivity of top electrode decreased, heating temperate was increased.

  • PDF

일체형 삼상 고온 초전도 한류기의 단락 특성 해석 (The conceptual design and analysts of three phase superconducting fault current limiter)

  • 이승제;이찬주;이창열;장미혜;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.94-97
    • /
    • 1998
  • The conceptual design of integrated three phase superconducting fault current limiter (SFCL) is presented. And through simulation of power system where this SFCL is installed, the characteristics of this SFCL is analyzed. It is like three-phase transformer. So it has the same characteristics with inductive single phase SFCL. But it has more merits than single phase SFCL. Differently to single phase SFCL, integrated three phase SFCL induces impedance at all phase by any single phase fault to protect the power system more safely.

  • PDF

3상 일체화된 자속구속형 전류제한기의 동작특성 (Operational Characteristics in integrated Three-Phase a Flux-Lock type SFCL according to Fault Conditions)

  • 이나영;최효상;정수복;이상일;남긍현;임성훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.467-470
    • /
    • 2006
  • Superconducting fault current(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault current of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operating characteristics. We compared additive polarity winding with the subtractive one in the flux lock reactor. Its turns ratio each phase between the primary and the secondary coils is 63:42. When a single line-to-ground fault occurred in any phase, the peak value of line current in the fault phase of the additive polarity winding increased up to 31.44[A] during first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to 81.77[A] under the same conditions. This is because the current flow between the primary and the secondary windings becomes to be additive or subtractive in each winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to ground fault.

  • PDF

삼각파 비교 PWM 기법에 있어서 단일 전류센서에 의한 삼상 전류 측정 및 전압 왜곡 보상 (The Measurement of 3-Phase Current with Single Current Sensor and the Compensation of Voltage Distortion in Carrier-Based PWM Technique)

  • 김경서
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.292-298
    • /
    • 2003
  • 교류전동기의 가변속 운전에 사용되는 삼상 인버터에는 두개 또는 세개의 전류센서가 장착되며 이를 이용하여 삼상 교류전류를 측정한다. 전류센서의 갯수를 줄이기 위하여 개발된 것이 직류링크에 한개의 전류센서로 직류전류를 측정하고 측정된 전류 값과 스위칭 상태로부터 삼상 교류전류를 추정하는 방법이다. 전류를 정확히 측정하려면 스위칭 상태가 최소 측정시간 이상 유지되어야 하며, 이를 위한 펄스폭 조정과 이에 따른 전압 왜곡의 보상 방법이 연구되어 왔다. 그러나 기존에 발표된 방식들은 공간벡터 전압변조법에는 적합하지만 산업체에서 널리 쓰이는 펄스폭 변조 방식인 삼각파 비교법에 적용하기에는 어려운 면이 많다. 본 연구에서는 삼각파 비교법에 적합한 전류 측정 방식과 전압왜곡 보상 방식을 제안하고 이의 타당성을 실험을 통하여 검증하였다.