• 제목/요약/키워드: current measurement

검색결과 3,865건 처리시간 0.03초

KTX 주행안정성 평가를 위한 진동가속도 계측데이터의 신호처리에 관한 연구 (A Study on The Measurement System of Acceleration Data To Estimate Operating KTX High Speed Train)

  • 강태원;김유승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1020-1023
    • /
    • 2009
  • A purpose of this study measure the acceleration of operating KTX high speed train to find out something wrong to obtain reliable the acceleration measurement data. The existing measurement system come about a difference between measurement data of running off the track with the acceleration measurement data of operating KTX high speed train. Therefore, the measurement system needs make up for the weak points in the current system. This study analyze existing measurement system and the acceleration measurement data to introduce the synchronization of the existing measurement system and the acceleration measurement and will be reasonable to this sampling through field test.

  • PDF

전기철도 부하모델링을 위한 신형 전기기관차 측정 및 결과분석 (Measurement and Analysis for Electric Locomotive Modeling)

  • 김주락;한문섭;장동욱;이기원;심건보;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.403-408
    • /
    • 2003
  • This paper presents measurement to develop load model for electric locomotive. Load model is defined as polynomial form and each coefficient is solved by the least square method. Therefore, many data is required for using this method. The measurement is performed on KNR line, from Chongryangri to Donghae. The subject of measurement is voltage, current, active power, reactive power an frequency for EL8100.

  • PDF

한국산업(韓國産業)의 측정기술인력(測定技術人力) 수급실태(需給實態) 조사연구(調査硏究) (A Survey Study on the Demand and Supply of Measurement Labor in Korean Industry)

  • 이동수;김동진;안종찬
    • 품질경영학회지
    • /
    • 제21권1호
    • /
    • pp.11-21
    • /
    • 1993
  • In this paper, we survey the current status of measurement labor in Korean Industry. At the same time we try to predit the demand and supply of measurement labor to suggest policy measures for equilibrium in measurement labor market. We use a general production function for the prediction which include a set of general homethetic production function.

  • PDF

2상 유도전동기의 벡터제어를 위한 저가형 전류측정 방법 (Low-Cost Current Measurement Method for Vector Control of 2-Phase Induction Motor)

  • 오광호;윤덕용
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.634-638
    • /
    • 2015
  • 2상 유도전동기의 벡터제어를 위해서는 전동기로 입력되는 상전류를 실시간으로 측정해야 한다. 일반적으로 전동기의 상전류는 인버터의 출력단에 2개의 홀전류센서를 삽입하여 측정한다. 그러나, 홀전류센서는 가격이 비싸고, 2상 유도전동기용 벡터제어 인버터는 주로 시스템의 가격이 낮은 저전력 응용분야를 대상으로 연구가 진행되고 있으므로 홀전류센서를 사용하는 것은 경제성 측면에서 부적합하다. 따라서, 본 논문에서는 인버터의 출력단에 고가의 홀전류센서 대신 션트저항을 삽입하고, 이것의 양단 전압을 차동 증폭기로 증폭하여 모든 운전영역에서 정밀하게 상전류를 측정하는 방법을 제안한다. 이를 220[V]/360[W]급의 2상 유도전동기 벡터제어 인버터에 적용하였으며, 제안된 방법의 유효성은 컴퓨터 시뮬레이션과 실험을 통하여 검증하였다.

접지저항 측정을 위한 보조전극 위치에 따른 접지저항 비교 분석 (The Comparison and Analysis about Earth Resistance for Measuring of Earth Resistance by Measurement Positions of Auxiliary Poles)

  • 한운기;정진수;김재철
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.128-133
    • /
    • 2009
  • 본 논문에서는 전류보조전극 및 전위보조전극의 접지저항 측정위치에 따른 접지저항 측정결과를 비교 분석하였다. 국내의 경우 접지전극의 대각선 길이의 6.5배 이상에서 접지저항을 측정하고 있으나 도심지역에서는 이와 같은 방법은 한계를 나타내고 있다. 이를 해결하기 위해 본 논문에서는 접지저항 측정시 접지전극, 전류보조전극과 전위 보조전극간의 거리, 각도를 변경하여 접지저항을 측정하였다. 측정결과 접지전극과 전류보조전극간의 거리를 50[m] 이상, 전위보조전극을 30[m] 이상 이격을 하고 전류보조전극과 전위보조전극을 45도 이상 각도를 유지할 경우 안정적인 접지저항이 측정되었다.

Bi-2223 초전도 테이프의 접촉식 Ic 측정을 위한 단자 형상 및 압력 조사 (Study on terminal shape and pressure for contact type Ic measurement of long Bi-2223 tape)

  • 하동우;양주생;하홍수;오상수;권영길;류강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 초전도 자성체
    • /
    • pp.25-28
    • /
    • 2002
  • Contact type Ic measurement system is needed to measure Ic continuously for long Bi-2223 tapes. Voltage and current terminals were designed several shapes for 4-probe method Ic measurement. Voltage terminals were made with brass and current terminals were made with Cu. We used 2 kinds of Bi-2223 tapes with different strength. When we measured Ic of Bi-2223 tape with Ag-Mg sheath, The proper weight was 0.3 kg and sharp pin type was better. according to voltage terminal shape and load. In case of Bi-2223 tape with Ag-Mn sheath, the proper terminal weight was 4 kg and sharp pin type was bad. It was possible to make continuous contact type Ic measurement system because We could get proper data - terminal shapes and loads - through these experiments.

  • PDF

Vision-based multipoint measurement systems for structural in-plane and out-of-plane movements including twisting rotation

  • Lee, Jong-Han;Jung, Chi-Young;Choi, Eunsoo;Cheung, Jin-Hwan
    • Smart Structures and Systems
    • /
    • 제20권5호
    • /
    • pp.563-572
    • /
    • 2017
  • The safety of structures is closely associated with the structural out-of-plane behavior. In particular, long and slender beam structures have been increasingly used in the design and construction. Therefore, an evaluation of the lateral and torsional behavior of a structure is important for the safety of the structure during construction as well as under service conditions. The current contact measurement method using displacement meters cannot measure independent movements directly and also requires caution when installing the displacement meters. Therefore, in this study, a vision-based system was used to measure the in-plane and out-of-plane displacements of a structure. The image processing algorithm was based on reference objects, including multiple targets in Lab color space. The captured targets were synchronized using a load indicator connected wirelessly to a data logger system in the server. A laboratory beam test was carried out to compare the displacements and rotation obtained from the proposed vision-based measurement system with those from the current measurement method using string potentiometers. The test results showed that the proposed vision-based measurement system could be applied successfully and easily to evaluating both the in-plane and out-of-plane movements of a beam including twisting rotation.

대지 위험전압 측정기의 설계 및 적용 (Design and Application of a Ground Risk Voltage Measurement System)

  • 장운용;차현규;차상욱;박대원;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.250-255
    • /
    • 2011
  • This paper dealt with the design, fabrication and application of a risk voltage measurement system (RVMS) which analyzes the step and touch voltages in electrical grounding systems. The RVMS supply 300 V and 1.4 A in ranges from 40 Hz to 1 kHz as the test power source. A DAQ module having resolution of 400 kS/s and 16 bit is equipped with 7 inputs for measuring voltage and current. Also, a noise elimination algorithm of digital filter was applied to reduce the measurement error caused by external noises as a commercial frequency current. The performance of the RVMS was evaluated by measurement of the step and touch voltage according to the IEEE standard 80 and 81 in a grounding system with a 10 m counterpoise. The result showed that the RVMS analyzes the risk voltage with the error below 5%.

고속선 귀선전류 측정값 비교 및 분석 (Comparison and Analysis of Return Current Measurement Values on High Speed Line)

  • 김용규;김주엽;오세찬;백종현;윤용기;곽우현
    • 전기학회논문지
    • /
    • 제66권5호
    • /
    • pp.877-884
    • /
    • 2017
  • A method of common earth, which is proposed by French Railway(SNCF) and is applied to high speed railway, minimizes the effect of the traction return current from tracks so that trackside electric devices can be protected and operation and maintenance staffs are kept out from injury in an electric railway environment. According to it, all the new domestic electric railway lines are replaced from existing individual earth method to the common earth method. In this paper, we analyze the correlation between common earth method and traction return current to prove whether the common earth has surely contributed to minimize the effect of the traction return current. The analysis was done based on the measurement of the traction return current at the domestic high speed railway line.

요실금 치료용 자기 자극기의 자속밀도 및 유도전류 측정 (Measurement of Magnetic Flux and Induced Current in Magnetic Stimulation for Urinary Incontinence Treatment)

  • 한병희;최경무;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.318-326
    • /
    • 2009
  • A simple method for measuring magnetic flux and induced current in magnetic nerve stimulation for urinary incontinence treatment is proposed. Unlike electric nerve stimulation, direct measurement of the induced current in magnetic nerve stimulation is impossible. Since induced currents stimulate nerves or muscles in magnetic nerve stimulation, measuring induced current is very important in validating stimulation efficacy and securing safety. The magnetic flux measuring system is composed of 6 layers with pick-up coils of 7 by 7 in each layer, and the induced current measuring system is composed of 6 layers with 7 concentric circular coils in each layer. The proposed method can be used in the design or performance test of a magnetic nerve stimulator for many clinical applications such as urinary incontinence treatment, activation of peripheral nerves, and transcranial magnetic stimulation.