• Title/Summary/Keyword: current injection

Search Result 1,048, Processing Time 0.143 seconds

Recent Trends and Prospects of Chemical Enhanced Oil Recovery (석유회수증진을 위한 화학적 공법 연구 동향 및 전망)

  • Choi, Youngil;Kang, Pan-Sang;Lim, Jong-Se
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.660-669
    • /
    • 2018
  • Enhanced oil recovery (EOR) is a method used to improve the recovery factor of remaining hydrocarbon in reservoir. Polymer and surfactant EOR techniques have limitations depending on reservoir or production conditions (temperature, salinity, etc.) because the polymer and surfactant are highly affected by the reservoir conditions. In this study, analysis of the current improvements to chemical substances and application technologies was performed based on recent research data. Conventional polymer is readily degraded by the conditions of high temperature and high salinity. Therefore, new polymers and injection techniques have been developed to remediate such problems. In addition, surfactant applicable to shale and carbonate reservoirs is developed as petroleum recovery expands to unconventional reservoirs. However, these chemical substances are not widely used in the current oil fields due to high costs. Therefore, further studies must be conducted to reduce the cost and thus increase the effectiveness of EOR techniques.

Initial Rotor Polarity Detection of Single-phase Permanent Magnet Synchronous Motor Based on Virtual dq-axis (단상 영구자석 동기 전동기의 가상 dq축 기반 초기 회전자 자극 검출)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Lee, Ki-Chang
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1004-1010
    • /
    • 2020
  • This paper proposes an initial rotor magnetic pole detection method for single-phase permanent magnet synchronous motors. The target motor cannot obtain position information based on the back emf in the low speed and stop state. Therefore, an open loop starting process is required, and in this process, initial rotor position information for low current and soft start is need. The proposed initial rotor magnetic pole detection algorithm considers the effect of asymmetric air- gap and magnetic flux. In addition, the high-frequency voltage signal injection and the offset voltage for accurate detection is used. As a result, the permanent magnet poles are is determined by acquiring the maximum value of the induced current using the virtual dq-axis.

Hybrid argon plasma coagulation in Barrett's esophagus: a systematic review and meta-analysis

  • Sagar N. Shah;Nabil El Hage Chehade;Amirali Tavangar;Alyssa Choi;Marc Monachese;Kenneth J. Chang;Jason B. Samarasena
    • Clinical Endoscopy
    • /
    • v.56 no.1
    • /
    • pp.38-49
    • /
    • 2023
  • Background/Aims: Patients with Barrett's esophagus are at increased risk of developing esophageal adenocarcinoma. Endoscopic therapies aim to eradicate dysplastic and metaplastic tissues. Hybrid argon plasma coagulation (hybrid-APC) utilizes submucosal fluid injection to create a protective cushion prior to ablation that shields the submucosa from injury. We performed a pooled meta-analysis to evaluate the safety and efficacy of hybrid-APC. Methods: We conducted a systematic search of major electronic databases in April 2022. Studies that included patients with dysplastic and non-dysplastic Barrett's esophagus undergoing treatment with hybrid-APC were eligible for inclusion. Outcome measures included complete remission of intestinal metaplasia (CR-IM), stricture formation, serious adverse events, and number of sessions necessary to achieve CR-IM. Results: Overall pooled CR-IM rate for patients undergoing hybrid-APC was 90.8% (95% confidence interval [CI], 0.872-0.939; I2=0%). Pooled stricture rate was 2.0% (95% CI, 0.005-0.042; I2=0%). Overall serious adverse event rate was 2.7% (95% CI, 0.007-0.055; I2=0%). Conclusions: Results of the current meta-analysis suggest that hybrid-APC is associated with high rates of CR-IM and a favorable safety profile. Interpretation of these results is limited by the inclusion of retrospective cohort and case series data. Randomized controlled trials that standardize treatment and outcome evaluation protocols are necessary to understand how this treatment option is comparable to the current standards of care.

Design of a Large-density MTP IP (대용량 MTP IP 설계)

  • Kim, YoungHee;Ha, Yoon-Kyu;Jin, Hongzhou;Kim, SuJin;Kim, SeungGuk;Jung, InChul;Ha, PanBong;Park, Seungyeop
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.161-169
    • /
    • 2020
  • In order to reduce the manufacturing cost of MCU chips used in applications such as wireless chargers and USB-C, compared to DP-EEPROM (Double Poly EEPROM), which requires 3 to 5 additional process masks, it is even more necessary MTP(Multi-Time Programmable), which is less than one additional mask and have smaller unit cell size. In addition, in order to improve endurance characteristics and data retention characteristics of the MTP memory cell due to E/P(Erase / Program) cycling, the distribution of the VTP(Program Threshold Voltage) and the VTE(Erase Threshold Voltage) needs to be narrow. In this paper, we proposed a current-type BL S/A(Bit-Line Sense Amplifier) circuit, WM(Write Mask) circuit, BLD(BL Driver) circuit and a algorithm, which can reduce the distribution of program and VT and erase VT, through compare the target current by performing the erase and program pulse of the short pulse several times, and if the current specification is satisfied, the program or erase operation is no longer performed. It was confirmed that the 256Kb MTP memory fabricated in the Magnachip semiconductor 0.13㎛ process operates well on the wafer in accordance with the operation mode.

A Study on Accounting for Nursing Cost by Korean Diagnosis Related Groups (K - DRGs) (종합병원(綜合病院)의 간호행위양상(看護行爲樣相)에 따른 간호원가(看護原價) 산정(算定)에 관(關)한 연구(硏究))

  • Oh, Hyo-Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.5-46
    • /
    • 1989
  • The current medical payment Insurance Rates in Korea stipulate charges for medical treatment by the doctor, pharmaceutist, medical technician and maternity nurse. But unfortunately didn't specify those charges for nursing done by the professional nurse. Only basic nursing fee is accounted insufficiently in current medical insurance fee schedule. therefore, Being face with covering entire people by medical insurance by 1991, It seems that the problems pertaining to operating the hospital and medical insurance system would be incessantly expanded in that no mention is made of medical charges rendered by major medical producer service in the current system, For that reason, this study made an attempt to clarify the importance the professional nursing puts of the current medical payment. The purpose of this study was to accounting nursing fee which diveded into the current medical fee schedule. (Method) 1. Data collection; Importance and difficulties in nursing activities was conducted in 'S' National University Hospital. Total nursing activities were selected 72 items which included direct care and indirect care. This study was conducted to evaluating the degree of importance and difficulties according to nursing activities through questionnaire to 204 RN. and so relative difficulties (acuity) were computered because the nursing cost level of each nursing service was differently established by the equivalent coefficient according to degree of relative difficulty and time required. 2. Calculation of cost according to nursing activities; After 47 nursing activities were selected in General surgery nursing units, calculation of nursing cost was as follows Cost of Nursing activity = (relative difficulty X Average hourly wage and benefits of nurse) + material cost of nursing -t- Average nursing administration cost So, Calculated cost by nursing activities was compared to current non-insured and insurance rate. 3. Calculation of nursing cost by K - DRG ; Total of 578 patients who were hospitalized in General Surgery units from January to March 1988 ware classified by K - DRG After estimation of total nursing cost based on the K-DRG, verified the appropriateness of basic nursing fee in medical insurance rate (Results) 1. Analysis of degree of importance and difficulties were 4.16 and 3.67 based on 5 point scale. This score were judged that it is worthy specifying the nursing fee 2. The nursing cost of 47 nursing service items in general surgery patients showed that the average cost of nursing activity was \1374.5 and The lowest cost was \217 of 'oral administration nursing' item, The highest cost was \11,025 of 'saline enematill clear' item 3. The result of comparison between the calculated cost by nursing activities against the current non-insured and insurance rate showed that 13 items(27.7%) involved to payment of insurance rate, 9 items(19.1%) involved to non-insured rate, remainder 25 items (53.2%) were not charged anywhere of total 47 nursing activities 4. When calculated cost by nursing activities was 100. current insurance rate was 62.3, non-insured rate was 176.6. Therefore this showed that most of non-insured rate were higher than calculated nursing cost. The insurance rate, however, were lower than it. Reim-bursement was imputed to non-insured patients. So the current rate system became estrainged from cost system. When Remainder 25 items of nursing activities compared' to \1390 of daily basic nursing fee per patient belonged to payment as a insurance fee schedule, basic nursing fee schedule was 1-2% of calculated cost of nursing activities. Therefore it showed that nursing fee was not counted adequately in it. 5. Nursing cost by K-DRG estimated in chart review based on counting number of nursing activities and length of stay The result showed that average amount of total nursing cost was \183828.1 Comparison of nursing cost calculated by K- DRG and basic nursing fee schedule showed that only 12.3% of nursing cost was charged (Conclusion) From the above research result, It is fact that nursing prime cost should be estimated more accurately and included adequately in current medical payment system. The payment system of nursing activities should be introduced not only nursing activities of drug administration and injection fee belonged to insurance fee schedule but also most nursing activities belonged not to mekical fee schedule. Even if introducing payment system of nursing activities, It should be estimated scientific method of Accounting nursing cost So nurses could offer nursing care of good quality, thereby they could make a great contribution not merely to the convalescence of the patient but to the promotion of the people's health.

  • PDF

Development of Optical Signal Transmission for the KSTAR Project Pertaining to Instrumentation and Control of the Neutral Beam Test Stand at KAERI

  • Jung, Ki-Sok;Oh, Byung-Hoon
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.3
    • /
    • pp.289-295
    • /
    • 2005
  • Instrumentation and Control (I&C) of the Neutral Beam Test Stand (NB- TS) Facility at the Korea Atomic Energy Research Institute (KAERI) for the Korea Superconducting Tokamak Advanced Research (KSTAR) project has been underway since the start of the project to answer the diverse requests arising from the various facets of the development and construction phases of the project. Optical signal transmission constitutes a significant portion of I&C works and has been performed for the entirety of the project. During the NB- TS construction and related experiments, significant achievements to a more accurate as well as more refined optical signal transmissions have been made. Examples of those I&C works that utilized the optical signal transmission are the Langmuir probe signal transmission, gradient grid current signal transmission, gas flow control and signal transmission, ion source temperature measurement, beam line component temperature monitoring, and coolant flow signal transmission, etc. These optical signal transition provisions are now performing part of the indispensable functions for the proper operation of the NB- TS facility. Attained experience and expertise are expected to be well applied to the upcoming main neutral beam injection (NBI) system construction for the KSTAR project.

Effect of Turbulator on Heat/Mass Transfer for Impingement/Effusion Cooling System (분사홀에 설치된 난류촉진제에 따른 충돌/유출면에서의 열/물질전달 특성)

  • Hong, Sung-Kook;Lee, Dong-Hyun;Kim, Young-Do;Cho, Hyung-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.24-30
    • /
    • 2008
  • In order to enhance the heat/mass transfer, a turbulator has been installed at the exit of injection hole for the impingement/effusion cooling system. The local heat/mass transfer coefficients have been obtained by a naphthalene sublimation method. Experiments have been carried out at the fixed jet Reynolds number of 10,000. Two turbulators with different diameter have been used in the current study. The result presents that the turbulator leads to the increase in flow mixing and jet velocity, consequently enhancing the heat/mass transfer at a stagnation region. Further, the stagnation region is divided into four small areas with peak value. In the existence of initial crossflow, the stagnation regions move downstream and low heat/mass transfer regions are formed regardless of the installation of turbulator. However, the increased jet velocity by turbulator reduces the crossflow effect against the jet, resulting in decrease of low heat/mass transfer regions. Compared to the case without turbulator, the installation of turbulator yields $5{\sim}10%$ augmentation in averaged Sh value.

Analysis of Hospital Services for Elderly Inpatients (노인 입원환자 병원서비스 분석)

  • Chang, Hyun Sook
    • Quality Improvement in Health Care
    • /
    • v.7 no.1
    • /
    • pp.18-31
    • /
    • 2000
  • Background : This study is to identify the inappropriate hospital services for elderly inpatients over 65 years in general hospital with acute care functioning. Consequently elderly inpatient care and the management of long-term care facilities are key issues for current government health policy. Method : The survey was conducted for two months for all inpatients over 65 in 7 general hospitals, 6 work sampling days randomly selected. In each survey day, the subjective judgement by medical staff on the degree of acute care needs and by nursing unit manager on hospital services of each inpatients was also conducted. Result : The total number of cases collected are 2,541 elderly inpatients, according to subjective judgements by medical staff on inpatient condition. However 46.8% of cases are turned out to be non-acute care group. The frequency of medical services provided to non-acute group are 2~3 vital sign checks per day 78.2%, IV injection 40.1%, antibiotics medication 20.2%. Conclusion : Lots of elderly patients' who are staving in acute hospitals, at present need to be transferred to long-term care facilities. However, there was been shortage of long-term care facilities. It is expected to identify the need of elderly inpatients and therefore, to provide cost-effective, appropriate and good quality health services to elderly inpatients depending on their needs.

  • PDF

A Study on the Feasibility of the Electrostatic Cell (PN접합 SCR내 전하주입을 통한 정전기전지 제작 가능성에 관한 연구)

  • Kang Hoe-Jong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.9-12
    • /
    • 2005
  • This paper describes the feasibility of the electrostatic cell using carrier injection in SCR(space charge region) of PN junction. It compares the principle of the electrostatic cell's operation with the solar cell's. According to the experiment and calculation of this paper, when the cross section area of the device is $0.0001cm^2$, the device current becomes 0.15mA which is practically high enough. This paper proposes that the electrostatic cell can be used as a physical battery.

Study on Ignition Characteristics Relating to Igniter Penetration Depth in a Model Sector Combustor (모델 섹터 연소기의 점화기 깊이에 따른 점화특성 연구)

  • Jin, Yu-In;Ryu, Gyong Won;Min, Seong Ki;Kim, Hong Jip
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.2
    • /
    • pp.36-41
    • /
    • 2017
  • Aero gas turbine engines must demonstrate their ability to be ignited on ground conditions or relighted in flight. The electric spark ignition is usually used in current aero gas turbine engines. Experiments on ignition characteristics relating to spark igniter penetration depth under atmospheric pressure and temperature conditions were conducted on the model combustor which is scaled in 1/18. Exciter was operated during 2 seconds, and successful ignition phenomena were confirmed by the pressure rising sharply in combustor. In addition, instantaneous ignition images were captured by a high-speed camera. It showed kernel propagation and successful ignition events in the sector model combustor. Ignition test results showed that ignition limit with increase in penetration depth of the igniter plug was wider. When the penetration depth of the igniter plug increased under the same fuel injection pressure condition, successful ignition events were obtained in higher differential pressure conditions between inlet and outlet of the combustor. The results demonstrate that the ratio of the combustible mixture, which is exposed to the high temperature environment around the igniter plug tip, increases. Thereby affect the combustor ignition performance.